• Title/Summary/Keyword: N removal

Search Result 2,203, Processing Time 0.031 seconds

Nitrate Removal in a Packed Bed Reactor Using Volatile Fatty Acids from Anaerobic Acidogenesis of Food Wastes

  • Lim, Seong-Jin;Ahn, Yeong-Hee;Kim, Eun-Young;Chang, Ho-Nam
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.538-543
    • /
    • 2006
  • A packed bed reactor (PBR) was fed with nitrate containing synthetic wastewater or effluent from a sequencing batch reactor used for nitrification. The C source introduced into the PBR consisted of volatile fatty acids (VFAs) produced from anaerobic acidogenesis of food wastes. When nitrate loading rates ranged from $0.50\;to\;1.01\;kg\;N/m^{3}{\cdot}d$, the PBR exhibited $100{\sim}98.8%\;NO_{3}^{-}-N$ removal efficiencies and nitrite concentrations in the effluent ranged from $0\;to\;0.6\;NO_{2}^{-}-N\;mg/L$. When the PBR was further investigated to determine nitrate removal activity along the bed height using a nitrate loading rate less than $1.01\;kg\;N/m^{3}{\cdot}d$, 100% nitrate removal efficiency was observed. Approximately 83.2% nitrate removal efficiency was observed in the lower 50% of the packed-bed height. When reactor performance at a C/N ratio of 4 and a C/N ratio of 5 was compared, the PBR showed better removal efficiency (96.5%) of nitrate and less nitrite concentration in the effluent at the C/N ratio of 5. VFAs were found to be a good alternative to methanol as a carbon source for denitrification of a municipal wastewater containing 40 mg-N/L.

Studies on the Water Purification Using Glycine max Merr Seedling (콩(Glycine max Merr)유묘를 이용한 수질정화에 관한 연구)

  • 김순진;나규환
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.50-54
    • /
    • 1997
  • The removal efficiency of nutrient was investicated by using Glycine max Meer seedling. After budding, Glycine max Merr was raised at darkness for 4 days. During cultivation, the removal efficiency of $NO_2-N+NO_3-N$ was up to 90% with initial concentration of 20-100 ppm. The removal efficiency of PO$_4$-P was up to 80% with initial concentration at 30 ppm, but it was down to 22% and 27% at 40 ppm and 50 ppm. When the removal efficiency of nutrient was compared with alternating 12 hours' light and darkness, the removal efficiency of NO$_2$-N + NO$_3$-N was up to 90% at below 60 ppm. It was not different from each other. But it was particularly low about 62% and 34% at 80 ppm and 100 ppm in alternating 12 hours' light. The removal efficiency of PO$_4$-P was low at alternating 12 hours' light between 10-50 ppm on the whole range. The neutralizing capacity of pH was shown in acidity and alkalinity except strong acidity(below pH 3). The initial pH was neutralized at 6.0-7.7 of pH after 4 days. Particularly, Glycine max Meer seedling that was difference from other water plants, was shown the neutralizing capacity in strong alkalinity.

  • PDF

Biological Treatment of Nutrients and Heavy Metals in Synthetic Wastewater Using a Carrier Attached to Rhodobacter blasticus

  • Kim, Deok-Won;Park, Ji-Su;Oh, Eun-Ji;Yoo, Jin;Kim, Deok-Hyeon;Chung, Keun-Yook
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.666-674
    • /
    • 2022
  • The removal efficiencies of nutrients (N and P) and heavy metals (Cu and Ni) by Rhodobacter blasticus and R. blasticus attached to polysulfone carriers, alginate carriers, PVA carriers, and PVA + zeolite carriers in synthetic wastewater were compared. In the comparison of the nutrient removal efficiency based on varying concentrations (100, 200, 500, and 1000 mg/L), R. blasticus + polysulfone carrier treatment showed removal efficiencies of 98.9~99.84% for N and 96.92~99.21% for P. The R. blasticus + alginate carrier treatment showed removal efficiencies of 88.04~97.1% for N and 90.33~97.13% for P. The R. blasticus + PVA carrier treatment showed removal efficiencies of 18.53~44.25% for N and 14.93~43.63% for P. The R. blasticus + PVA + zeolite carrier treatment showed removal efficiencies of 26.65~64.33% for N and 23.44~64.05% for P. In addition, at the minimum inhibitory concentration of heavy metals, R. blasticus (dead cells) + polysulfone carrier treatment showed removal efficiencies of 7.77% for Cu and 12.19% for Ni. Rhodobacter blasticus (dead cells) + alginate carrier treatment showed removal efficiencies of 25.83% for Cu and 31.12% for Ni.

Feasibility of Industrial by-products as a Seed Crystal of Struvite Crystallization for the Removal of Highly Concentrated Nitrogen and Phosphorus (고농도의 질소와 인제거를 위한 Struvite 정석반응의 정석재로서 산업부산물의 이용 가능성)

  • Yim, Soo-Bin
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.664-672
    • /
    • 2010
  • This study was performed to evaluate the feasibility of industrial by-products such as converter slag, olivine, red mud and fly ash as a seed crystal of struvite crystallization for the removal of highly concentrated $NH_4-N$ and $PO_4-P$. In the kinetic experiments, more than 90% of $NH_4-N$ and $PO_4-P$ was eliminated by struvite crystallization within 30 minutes of reaction time. The pH range in meta-stable region of struvite crystallization was found to be pH 7.0~9.0 under the Mg:N:P=1:1:1 equi-molar condition with 100 mg/L of $NH_4-N$. Total removal efficiencies of $NH_4-N$ and $PO_4-P$ by both struvite precipitation and crystallization were increased with the increase of pH. Removal efficiencies of $NH_4-N$ and $PO_4-P$ were significantly enhanced by struvite crystallization using industrial by-products as a seed crystal compared with those by struvite precipitation without seed crystal. Red mud, converter slag, olivine and fly ash enhanced the removal efficiencies of $NH_4-N$ by 40.9%, 37.7%, 28.4% and 16.4%, respectively. Removal efficiencies of $PO_4-P$ for converter slag, red mud, fly ash, olivine were increased by 3.7 times, 2.6 times, 72.4% and 68.0%, respectively. Converter slag and red mud showed higher feasibility as a seed crystal than others for the removal of highly concentrated $NH_4-N$ and $PO_4-P$. In particular, converter slag might have a high capacity of phosphorus removal.

The Study for Enhancement of Nitrogen Removal Efficiency in M-Dephanox Process (M-Dephanox 공정 질소 제거 효율 향상 방안에 관한 연구)

  • Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.74-82
    • /
    • 2006
  • In this study, development of M2-Dephanox and M3-Dephanox process has been tried to enhance the nitrogen removal of M-Dephanox process on the basis of previous study about M-Dephanox. The results showed that T-N removal efficiency of M3-Dephanox process was 8.9% or 11.3% higher than M-Dephanox or M2-Dephanox processes, respectively. This result is due to the lower $NO_3{^-}-N$ concentration in the effluent of M3-Dephanox than of M-Dephanox and M2-Dephanox processes. This results were recurrenced by PASS simulator. As result of simulation by PASS program, effluent $NO_3{^-}-N$ concentration of M3-Dephanox process was 1.4 mg/L and 3.6 mg/L lower than M-Dephanox and M2-Dephanox processes. In the study about optimization of M3-Dephanox processes by PASS program, SRT greatly affected T-N removal of M3-Dephanox process, whereas, the recycle rate and recirculation rate did little affect T-N removal efficiency of M3-Dephanox. In the study about optimization of reactors following the nitrification reactor of M3-Dephanox process, it was shown that the best optimum volume ratio of denitrification reactor, intermittently aerated reactor and anoxic reactor for the T-N removal were 29.1(%) : 32.7(%) : 38.2(%). T-N removal efficiency at this volume ratio was similar to T-N removal efficiency at the volume ratio of 36.3(%) : 36.3(%) : 27.4(%) designed for the lab-scale M3-Dephanox.

Isolation, identification and immobilized-cell characteristics of a bacterium that produces $N_2$ from $NH{_4}{^+}$ under an aerobic condition

  • Park, Kyoung-Joo;Cho, Kyoung-Sook;Kim, Jeong-Bo;Lee, Min-Gyu;Lee, Byung-Hun;Hong, Young-Ki;Kim, Joong-Kyun
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.450-455
    • /
    • 2005
  • To treat wastewater efficiently by a one-step process of nitrogen removal, a new strain of $N_2-producing$ bacteria from $NH{_4}{^+}$ under an aerobic condition was isolated and identified. By 16S-rDNA analysis, the isolate was identified as Enterobacter asburiae with 96% similarity. The isolate shows that the capacity of $N_2$ production under an oxic condition was approximately three times higher than that under an anoxic condition. The optimal conditions (pH, temperature and C/N ratio) of the immobilized isolate for $N_2$ production were found to be 7.0, $30^{\circ}C$ and 5, respectively. Under all the optimum reaction conditions, the removal efficiency of $COD_{Cr}$ and TN reached 56.1 and 60.9%, respectively. The removal rates of $COD_{Cr}$ and TN were highest for the first 2.5 hrs (with the removal $COD_{Cr}$ ratios of 32.1), and afterwards the rates decreased as reaction proceeded. For application of the immobilized isolate to a practical process of ammonium removal, a continuous bioreactor system exhibited a satisfactory performance at HRT of 12.1 hr, in which the effluent concentrations of $NH{_4}{^+}-N$ was measured to be 15.4 mg/L with its removal efficiency of 56.0%. The maximum removal rate of $NH{_4}{^+}-N$ reached 1.6 mg $NH{_4}{^+}-N/L/hr$ at HRT of 12.1 hr (with N loading rate of 0.08 $Kg-N/m^3-carrier/d)$. As a result, the application of the immobilized isolate appears a viable alternative to the nitrification-denitrification processes.

  • PDF

A Study on the Optimum Operating Conditions and Effects of Wastewater Characteristics in Electrochemical Nitrogen Removal Process (질소 제거를 위한 전기화학적 처리 공정의 최적 운전조건 및 폐수 성상에 따른 영향에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon;Song, Su-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • This study was performed under four operational conditions for nitrogen removal in metal finishing wastewater. The conditions include electrode gap, reducing agent, the recycling of treated wastewater in 1st step and the simultaneous treatment of nitrate and other materials. Result showed that the removal efficiency of $NO_3{^-}-N$ was highest at the electrode gap of 10 mm. As the electrode gap was shorter than 10 mm, the removal efficiency of $NO_3{^-}-N$ decreased due to increasing in concentration polarization on electrode. And, in case that the electrode gap was longer than 10 mm, the removal efficiency of $NO_3{^-}-N$ increased with an increase in energy consumption. Because hydrogen ions are consumed when nitrate is reduced, reducing reaction of nitrate was effected more in acid solution. As 1.2 excess amount of zinc was injected, the removal efficiency of $NO_3{^-}-N$ increased due to increasing in amount of reaction with nitrate. As the effluent from 1st step in the reactor was recycled into the 1st step, the removal efficiency of $NO_3{^-}-N$ increased. Because the zinc were detached from the cathode and concentration-polarization was decreased due to formation of turbulence in the reactor. The presence of $NH_4{^+}-N$ did not affect the removal efficiency of $NO_3{^-}-N$ but the addition of heavy metal decreased the removal efficiency of $NO_3{^-}-N$. As chlorine is enough in wastewater, the simultaneous treatment of nitrate and ammonia nitrogen may be possible. The problem that heavy metal decrease the removal efficiency of $NO_3{^-}-N$ may be solved by increasing current density or using front step of electrochemical process for heavy metal removal.

Determination of operation parameter on intermittently aerated activated sludge system by computer simulation model (컴퓨터 예측모델을 활용한 간헐폭기 활성슬러지 시스템의 운영인자 결정)

  • 이상일;서인석;이원호;손종렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.23-29
    • /
    • 1995
  • In this research effect of SRT, feeding pattern and reactor configuration on intermittently aerated activated sludge system was evaluated by using computer simulation model. T- N removal was affected to the SRT. SRT for the effective T- N removal was 156ay or longer. Feeding pattern in intermittently aerated activated sludge system was affect to the T- N removal. Feeding pattern which 100% loading to the first reactor was most effective for T- N removal. When multi- stage of 2- stage or more was operated, COD and T- N in effluent removal was nearly the same.

  • PDF

Evaluation of Pollutants Removal for Treated Wastewater Effluent and River Water by Meandering Constructed Wetland System (하수처리수와 하천수를 대상으로 한 생태적 수질정화 비오톱 시스템의 오염물질 제거에 대한 수질정화 평가)

  • Lee, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.131-139
    • /
    • 2012
  • Field experiment was performed from June 2010 to July 2011 to evaluate pollutants removal efficiency in the constructed wetland system for the treated wastewater and the river water. The wetland systems were constructed near Gyungan river. Two different systems with meandering shape were compared for seasonal base and operational period base. Several kinds of aquaculture are planted through the corridor of wetland system. Average removal rate of BOD, T-N and T-P for A system were 15.8%, 14.8% and 26.5%, respectively. Average removal rate of BOD, T-N and T-P for C system were 23.5%, 27.8% and 10.6%, respectively. The effluent from two wetland systems often exceeded effluent water quality standards for wastewater influent, however effluent water quality standards for river water. However, the wetland system can be useful to treat polluted river water and effluent from wastewater plant. Removal rate of pollutants in seasonal variation was the highest in summer for BOD and T-N, however the removal rates of T-P were higher in spring and autumn than in summer.

Ammonia-nitrogen Removal in Sea Water by Using Electrolysis (전기분해법에 의한 해수내의 암모니아성 질소 제거)

  • 이병헌;이제근;길대수;곽순열
    • Journal of Aquaculture
    • /
    • v.10 no.4
    • /
    • pp.435-438
    • /
    • 1997
  • Biological ammonia removal system have been used conventionally for the seawater fish farming. But this process requires long hydraulic retention times and large area. Also it has a trouble of NO3-N accumulation in the system. Therefore, this study was conducted to find out the feasibility of effective nitrogen removal efficiency in the sea water fish farming system by electolysis. As the result, electrolysis system showed a good ammonia and nitrate nitrogen removal and E. coli sterilization efficiencies. Because of the high salinities in the seawater for electron transfer, electrolysis is an effictive water treatment process for seawater fish farming. The relation among ammonia removal efficiency, hydraulic retention time (HRT) and electric wattage (watt) with 10 mm electrod distance isas follow ; log [$NH_4^$+-N(%)]=0.431log(HRT(sec)$\times$Watt)+0.88(r=0.950) And the relation between ammonia removal efficiency and residual chlorine concentration in the seawater is as follow; $$NH_4^+-N(%)=48\cdotlog[Residual\;chlorine(mg/\ell)+28(r=0.892)$$

  • PDF