• Title/Summary/Keyword: N loss

Search Result 2,533, Processing Time 0.035 seconds

Quality Changes and Shelf-life of Grill Sausages Re-pasteurized after Packaging during Chilled Storage (이차살균한 그릴소시지의 냉장 저장 중 품질 변화와 저장 수명)

  • 이근택;최원선;우문제;이정표
    • Food Science of Animal Resources
    • /
    • v.24 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Changes in quality characteristics and shelf-life of two types of grill sausage manufactured by using pork hind leg and re-pasteurized after packaging were investigated during storage at 5$^{\circ}C$ and 10$^{\circ}C$ up to 30 days. The total aerobic plate counts(APC) of N rnberger style grill sausage(NGS) and vegetable added grill sausage(VGS) were initially 3.08 and 3.57 log$\sub$10/CFU/$\textrm{cm}^2$, respectively, and gradually increased during storage time. After 30 days, the APC of NGS stored at 5$^{\circ}C$ and 10$^{\circ}C$ maintained relatively low at the levels of 5.32 and 6.58 log$\sub$10/CFU/$\textrm{cm}^2$, respectively. However, the APC of VGS exceeded the level of 8 log$\sub$10/CFU/$\textrm{cm}^2$ after 30 days at 5$^{\circ}C$ and after 20 days at 10$^{\circ}C$. pH was decreased with storage period, however it tended to increase after 30 days. The values of TBA and VBN for both sausages tended to increase with storage time, and this trend was pronounced at 5$^{\circ}C$ rather than at 10$^{\circ}C$. The purge loss was apparently increased in the VGS compared to the NGS sample as the storage period extended. According to the sensory evaluation, the marketing values of grill sausages stored at 5$^{\circ}C$ and 10$^{\circ}C$ were maintained until day 20 for NGS and day 14 for VGS, respectively.

Reduced Port Surgery for Prostate Cancer is Feasible: Comparative Study of 2-port Laparoendoscopic and Conventional 5-port Laparoscopic Radical Prostatectomy

  • Akita, Hidetoshi;Nakane, Akihiro;Ando, Ryosuke;Yamada, Kenji;Kobayashi, Takahiro;Okamura, Takehiko;Kohri, Kejiro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6311-6314
    • /
    • 2013
  • Background: While 5-port laparoendoscopic radical prostatectomy is standard practice, efforts have been focused in developing a single port surgery for cosmetic reasons. However, this is still in the pioneering stage considering the challenging nature of the surgical procedures. We have therefore focused on reduced port surgery, using only 2-ports. In this study, we compared 2-port laparoendoscopic radical prostatectomy (2-port RP) and conventional 5-port laparoscopic radical prostatectomy (LRP) for clinically localized prostate carcinoma and evaluated the potential advantages of each. Materials and Methods: From January 2010 to December 2010, all 23 patients with clinically localized prostate cancer underwent LRP. Starting November, 2010, when we introduced the reduced port approach, we performed this procedure for 22 consecutive patients diagnosed with early-stage prostate cancer (cT1c, cT2N0). The patients were matched 1:1 to 2-port RP or LRP for age, preoperative serum PSA level, clinical stage, biopsy and pathological Gleason grade, surgical margin status, pad-free rates and post-operative pain. Results: There was a significant difference in operative time between the 2-port RP and LRP groups ($286.5{\pm}63.3$ and $351.8{\pm}72.4$ min: p=0.0019, without any variation in blood loss (including urine) ($945.1{\pm}479.6$ vs $1271.1{\pm}871.8ml$: p=0.13). The Foley catheter indwelling period was shorter in the 2 port RP group, but without significance ($5.6{\pm}1.8$ vs $8.0{\pm}5.6$ days: p=0.057) and the total perioperative complication rates for 2 port RP and LRP were comparable at 4.5% and 8.7% (p=0.58). There was an improvement in pad-free rates up to 6 months follow-up (p=0.090), and significantly improvement at 1 year (p=0.040). PSA recurrence was 1 (4.5%) in 2-port RP and 2 (8.7%) in LRP. Continuous epidural anesthesia was used in most of LRP patients (95.7%) and in early 2-port RP patients (40.9%). In these patients, average total amount of Diclofenac sodium was 27.8mg/patient in 2-port RP and 50.0mg/patient in LRP. Conclusions: Thus the reduced port approach is as efficacious as LRP in terms of many outcome measures, with significant cosmetic advantages and reduction in post surgical pain. This method can be readily performed safely and therefore can be recommended as a standard laparoscopic surgery for prostate cancer in the future.

A clinical study on facial paralysis. (口眼와斜에 대한 臨床的 考察)

  • An, Su-Gi;Hwang, Choong-Yeon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.4 no.1
    • /
    • pp.89-98
    • /
    • 1991
  • Clinical study on the 114 facial paralysis patients, visited Won Kwang University Oriental Medical Hospital in Kwang ju from July 1990 to Jun 1991, was carried out. The results obtained are as follows. 1. Prevalence was almost same in both sexes and high in the age of 3 and 4 decades but distributed in an age group. 2. Majority of the patients were nomotensive, which meant blood pressure did not affect the incidence. 3. The incidence distributed in every occupations but high in housewife as 37 cases ($32\%$) and decreased gradually in office employee, labor worker, student and merchant in order. 4. Overwork, wind and cold, emotional stress, and numerous implicated agents were etiological factor. 5. The paralysis mostly occured in summer and winter as 40($35\%$) and 37 cases($32\%$) respectively, 18($16\%$) and 19cases($17\%$) were recorded respectively in spring and autumn. 6. The majority of patients showed only facial muscle paralysis without other complications, whose cure rate was $60\%$ (47 cases). The patients with auditory impairment or taste loss was less common and cure rate was low. 7. The number of the patients with migraine or mastoid pain was 81($71\%$), which was more than 33 patients($29\%$) with such pain. The cure rate was high in the patients without migraine than with migraine as a raito of 64 to $46\%$. 8. Most of duration from attack to admission were in a week as 86 cases($75\%$) and the patients with duration over 4 weeks 11 cases($10\%$). The cure rate of the patients in a week, was 54 cases($60\%$) and the patients over 4 weeks was none($0\%$), which meant shorter the duration was, the beter the result was. 9. Response on electro acupuncture on initiating therapy showed good in 39 cases($34\%$) the majority group, moderate in 37 cases, exellent in 29 cases and poor in 5 cases. 10. The results of treatment were as follows : asymptomatic in 58 cases($51\%$), improved n 40cases($35\%$), effective in 10 cases($9\%$) and ineffective in 6 cases($5\%$). 11. Cure rate according to the response on electro acupuncture showed $72\%$ in exellent group, $59\%$ in good group, $27\%$ in moderate groop, and $0\%$ in poor group. These show the better the response on the electro-acupuncture is, the higher the cure rate is, which will be able to indicate the prognosis of facial paralysis.

  • PDF

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

Ti:LiNbO3 three-waveguide type traveling-wave optical modulator; outer fed, anti-symmetrical Detuning (Ti:LiNbO3 세 도파로형 진행파 광변조기;바깥입사, 반대칭 Detuning)

  • 이우진;정은주;피중호;김창민
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.375-384
    • /
    • 2004
  • Switching phenomenon of a three-waveguide optical coupler was analyzed by using the coupled mode theory, and the coupling-length of the device was calculated by means of the FDM. CPW traveling-wave electrodes were designed by the CMM and SOR simulation techniques so as to satisfy the conditions of phase-velocity and impedance matching. Traveling-wave modulators were fabricated on a z-cut LiNbO$_3$ substrate. Ti was in-diffused in LiNbO$_3$ to make waveguides and Au electrodes were built on the waveguides by the electroplating technique. Insertion loss and switching voltage of the optical modulator were about 4 ㏈ and 15.6V. Network analyzer was used to obtain S parameters and corresponding RF response. From the measurement, parameters of the traveling-wave electrodes were extracted as such Z$_{c}$=39.2 $\Omega$, Neff=2.48, and a0=0.0665/cm((GHz) (1/2)). The measured optical response R(w) was compared with the theoretically estimated and both responses were shown to agree well. The measurement results revealed that the ㏈ bandwidth turned out to be about 13 GHz.

Physiological responses involved in reactive oxygen species (ROS) of rice plant under alone or multi artificial stress conditions

  • Kim, Yoonha;Waqas, Muhammad;Khan, Abdul Latif;Mun, Bong-Gyu;Yun, Byung-Wook;Lee, In-Jung
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.203-203
    • /
    • 2017
  • The Earth's climate is rapidly changing because of increasing carbon dioxide content in atmosphere so, climate prediction models anticipate that earth surface temperature will rise by 3 to $5^{\circ}C$ in next 50 to 100 years. Therefore, frequency of un-expected weather events such as drought, salinity, low or high temperature and flooding etc. will be increasing worldwide. Furthermore, increased atmosphere temperature can influence pests and pathogens spread as well. Therefore, to protect enormous grain loss from unexpected weather conditions, studies related with combine stress conditions like abiotic plus biotic stress condition are really required. Thus, our research focused on physiological responses under combined abiotic and biotic stress condition in rice plant. To induce uniform stress condition, we used NaCl (100 mM) and salicylic acid (0.5 and 1.0 mM SA) as each stress a stimulator. Each artificial abiotic and biotic stress inducer was applied to hydroponically grown rice seedlings alone or together for four day. The data were collected in a time-dependent manner [1, 2, 3 and 4 day(s) after treatment (DAT)] and were matched with our anticipation that shoot length and shoot fresh weight was decreased in solo and combined abiotic and biotic stress condition. The lipid peroxidation content was significantly increased ($1.5{\pm}0.2$ to $2.7{\pm}0.1mg$ mg of $MDA\;g^{-1}FW$) in the first two days in both stress exposed plants, and showed the opposite trend ($0.5{\pm}0.01$ to $0.1{\pm}0.001mg$ of $MDA\;g^{-1}FW$) in last two days under multi stress condition. Superoxide dismutase (SOD) activity did not showed difference in only biotic stress condition (alone 0.5 and 1.0 mM SA) as compared to control however, it was significantly increased in multi stress condition or solo abiotic stress condition whereas, catalase (CAT), and ascorbate peroxidase (APX) activities were significantly decreased in solo biotic and combined abiotic and biotic condition. In particular, both enzymes activities were more decreased in multi stress condition as compared to solo biotic stress condition. The results for relative mRNA expression level of CAT and APX enzymes were in agreement with results of spectrophotometric values. Correlation value between each stress condition and phenotypic data showed that biotic stress condition showed high correlation with activity of CAT and APX whilst, abiotic stress condition revealed significant correlation with SOD activity.

  • PDF

A Study for SCR Catalyst Reduction in Fast SCR Using Oxidation Catalyst (산화촉매를 이용한 Fast SCR에서의 SCR 촉매 저감 연구)

  • Lee, Jae Ok;Lee, Dae Hoon;Song, Young-Hoon;Oh, Dong-Kyu;Seo, Jung-Wook
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.333-336
    • /
    • 2013
  • Experimental investigation to estimate the feasibility of fast selective catalytic reduction (SCR) or oxidation catalyst combined ammonia SCR system to abate NOx in low temperature condition ($150{\sim}250^{\circ}C$) is reported. Because the conversion of NO to $NO_2$ is pre-requisite of the fast SCR process, the effect of the amount of oxidation catalyst to NO conversion to $NO_2$ was tested. 37, 45 and 51% of conversion rates were obtained for the OCV of 563000, 375000 and 281000 h, respectively. $De-NO_x$ performance in the case of $NO_2/NO_x$ ratio of 45% showed the best result in all tested temperature conditions. Comparison of the fast SCR and standard SCR with the condition of $NO_2/NO_x$ ratio of 45%, $200{\sim}250^{\circ}C$ and space velocity of 10000~30000 h showed that the fast SCR does not show much difference according to the variance of space velocity. Also it was shown that using the fast SCR, the volume of SCR catalyst can be reduced less than half of the standard SCR condition by increasing space velocity without the loss of $De-NO_x$ performance.

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Simultaneous Carbon and Nitrogen Removal Using an Integrated System of High-Rate Anaerobic Reactor and Aerobic Biofilter (고효율 혐기성반응조 및 호기성여상 조합시스템에 의한 질소·유기물 동시 제거)

  • Sung, Moon Sung;Chang, Duk;Seo, Seong Cheol;Chung, Bo Rim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.55-65
    • /
    • 1999
  • AF(anaerobic filter)/BAF(biological aerated filter) system and UASB(upflow anaerobic sludge blanket)/BAF system, of which system effluents were recirculated to the anaerobic reactors in each system, were operated in order to investigate the performance in simultaneous removal of organics and nitrogen in high-strength dairy wastewater. Advanced anaerobic treatment processes of AF and UASB were evaluated on applicability as pre-denitrification reactors, and BAF was also evaluated on the performance in oxidizing the remaining organics and ammonia nitrogen. At system HRTs of 4.0 to 4.5 days and recirculation ratios of one to three, the AF/BAF system could achieve more than 99% of organics removals and 64 to 78% of total nitrogen removals depending upon the recirculation ratio. Although the UASB/BAF system also showed more than 99% of organics removals, total nitrogen removals in the UASB/BAF system were 53 to 66% which are lower than those in the AF/BAF system at the corresponding recirculation ratios. Optimum recirculation ratios considering simultaneous removal of organics and nitrogen and cost-effectiveness, were in the range of two to three. The upflow AF packed with crossflow module media, as a primary treatment of the anaerobic reactor/BAF system, showed better performances in denitrification, SS removals, and gas production than the UASB. Higher loading rate of suspended solids from the UASB increased the backwashing times in the following BAF. Especially, at a recirculation ratio of three in the UASB/BAF system, the increase in head loss due to clogging in the BAF caused frequent backwashing, at least once d day. The BAF showed the high nitrification efficiency of average 99.2% and organics removals more than 90% at organics loading rate less than $1.4KgCOD/m^3/d$ and $COD/NH_3-N$ ratio less than 6.4. It was proved that the simplified anaerobic reactor/BAF system could maximize the organics removal and achieve high nitrogen removal efficiencies through recirculation of system effluents to the anaerobic reactor. The AF/BAF system can, especially, be a cost effective and competitive alternative for the simultaneous removal of organics ana nitrogen from wastewaters.

  • PDF

Changes in Renal Function by Nebulized Colistimethate Treatment (Colistimethate 분무요법 시행 환자에서 투여 전후 신기능의 변화)

  • Ahn, Hye Jin;Jung, Yoo Jin;Kim, Jae Song;Kim, Soo Hyun;Son, Eun Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.2
    • /
    • pp.92-98
    • /
    • 2017
  • Background: Nebulized colistimethate is increasingly used, because there are problems such as renal dysfunction and low distribution within the lungs when colistimethate is administered intravenously. This study was designed to compare and analyze the changes in renal function by of nebulized colistimethate treatment for its safe administration. Methods: This study retrospectively reviewed the electronic medical records of adult patients above 19 years old, receiving only the nebulized colistimethate at least 4 days in Yonsei university health system from Nov 2014 to Aug 2015. Acute kidney injury (AKI) was determined by using the RIFLE criteria (Risk, Injury, Failure, Loss and End-stage renal disease) according to serum creatinine (SCr) levels before and after use of nebulized colistimethate. Results: 48 patients were included our study and their SCr increased significantly after nebulized colistimethate treatment ($SCr_0$ vs. $SCr_1$; $0.85{\pm}0.80$ vs. $1.00{\pm}0.82mg/dL$, n=48, p<0.001), but the changes were in normal range according to the standards at Yonsei university health $system^a$. Among 48 patients, 38 patients were in the non-AKI group (79.2%), and 10 patients developed AKI (20.8%). Within the AKI group, 2 patients were in the Injury group (20%) and the other 8 in the Risk group (80%). Conclusion: There was no significant difference in age, dosage and duration of treatment between AKI group and non-AKI group (p>0.05). The study has a significance in that it reviewed the safety of nebulized colistimethate only treatment to national patients, analyzing its nephrotoxicity. It has confirmed that nebulized colistimethate is a safer method than intravenous injection, and requires to establish a guideline for the use of nebulized colistimethate in further studies with broader patient groups. $^a$ : SCr Male 0.68-1.19 mg/dL, Female 0.49-0.91 mg/dL.