• 제목/요약/키워드: Myocardial perfusion CT

검색결과 30건 처리시간 0.02초

CT Fractional Flow Reserve for the Diagnosis of Myocardial Bridging-Related Ischemia: A Study Using Dynamic CT Myocardial Perfusion Imaging as a Reference Standard

  • Yarong Yu;Lihua Yu;Xu Dai;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제22권12호
    • /
    • pp.1964-1973
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of CT fractional flow reserve (CT-FFR) for myocardial bridging-related ischemia using dynamic CT myocardial perfusion imaging (CT-MPI) as a reference standard. Materials and Methods: Dynamic CT-MPI and coronary CT angiography (CCTA) data obtained from 498 symptomatic patients were retrospectively reviewed. Seventy-five patients (mean age ± standard deviation, 62.7 ± 13.2 years; 48 males) who showed myocardial bridging in the left anterior descending artery without concomitant obstructive stenosis on the imaging were included. The change in CT-FFR across myocardial bridging (ΔCT-FFR, defined as the difference in CT-FFR values between the proximal and distal ends of the myocardial bridging) in different cardiac phases, as well as other anatomical parameters, were measured to evaluate their performance for diagnosing myocardial bridging-related myocardial ischemia using dynamic CT-MPI as the reference standard (myocardial blood flow < 100 mL/100 mL/min or myocardial blood flow ratio ≤ 0.8). Results: ΔCT-FFRsystolic (ΔCT-FFR calculated in the best systolic phase) was higher in patients with vs. without myocardial bridging-related myocardial ischemia (median [interquartile range], 0.12 [0.08-0.17] vs. 0.04 [0.01-0.07], p < 0.001), while CT-FFRsystolic (CT-FFR distal to the myocardial bridging calculated in the best systolic phase) was lower (0.85 [0.81-0.89] vs. 0.91 [0.88-0.96], p = 0.043). In contrast, ΔCT-FFRdiastolic (ΔCT-FFR calculated in the best diastolic phase) and CT-FFRdiastolic (CT-FFR distal to the myocardial bridging calculated in the best diastolic phase) did not differ significantly. Receiver operating characteristic curve analysis showed that ΔCT-FFRsystolic had largest area under the curve (0.822; 95% confidence interval, 0.717-0.901) for identifying myocardial bridging-related ischemia. ΔCT-FFRsystolic had the highest sensitivity (91.7%) and negative predictive value (NPV) (97.8%). ΔCT-FFRdiastolic had the highest specificity (85.7%) for diagnosing myocardial bridging-related ischemia. The positive predictive values of all CT-related parameters were low. Conclusion: ΔCT-FFRsystolic reliably excluded myocardial bridging-related ischemia with high sensitivity and NPV. Myocardial bridging showing positive CT-FFR results requires further evaluation.

허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study (One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study)

  • 김경목;이병욱;이동욱;김정수;장영도;방찬석;백종훈;이인수
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.33-37
    • /
    • 2010
  • 관상동맥질환의 진단 및 평가에 있어서 myocardial perfusion SPECT검사와 FDG를 이용한 myocardial PET검사 그리고 PET/CT에 장착된 64-slice CT를 이용한 coronary CT angiography를 동시에 실행함으로 검사의 신뢰도와 편의성을 한층 더 높이고자 한다. 먼저 약물부하 myocardial perfusion SPECT검사를 먼저 시행한다. 환자의 피폭경감을 위해서 $^{99m}Tc$-MIBI 10 mCi 로 주사하며 myocardial PET검사를 위해서 지방식을 먹지 않고 ursodeoxcholic acid 100 mg을 생수와 함께 복용하게 하여 1시간 후에 SPECT 영상을 얻는다. 이어서 myocardial FDG PET검사를 시행한다. 혈중의 지방산 농도를 낮추고 심장의 FDG섭취율을 증가시키기 위해 혈중 포도당 농도치에 따라 insulin과 Acipimox를 함께 사용하는 독창적인 경구 당 부하법을 사용하였으며, 환자의 피폭 경감을 위해서 $^{18}F$-FDG 5 mCi를 주사하고 1시간 후에 10분간 gated 영상을 얻으며 필요시 delay 영상을 얻는다. PET검사가 끝남과 동시에 환자는 동일한 position을 하고 연속해서 coronary CTA를 시행한다. 이 검사에서 가장 중요한 것은 심박동수 조절과 환자의 호흡협조이다. 심박동수를 65회 이하로 낮추기 위해 beta blocker 50 mg~200 mg을 의사와 상의하여 복용케 하고 호흡법을 충분히 연습을 시키다. 검사 직전에 isosorbide dinitrate를 3~5회 분무하여 혈관벽의 긴장을 낮추고 혈관을 확장시켜서 coronary artery의 해부학적 형태를 더욱 잘 나타낼 수 있게 한다. 촬영 시 CT 조영제를 4.0~5.0 mL/sec의 압력으로 주입하며 촬영을 한다. Coronary CTA를 이용하면 coronary artery stenosis가 잘 보이며, 약물부하 myocardial perfusion SPECT로 coronary CTA에서 보인 stenosis와 perfusion저하의 상관관계를 검토(culprit vessel 확인)할 수 있으며, FDG PET으로 hibernating myocardium 또는 infarction site의 viability를 확인할 수 있다. 한 가지 검사로 lesion site와 severity 및 치료에 대한 반응 예측이 가능함으로 약물치료, PCI, CABG 등 치료방향을 설정할 수 있다. 또한 모든 검사 과정들이 연속적으로 동시에 이루어지기 때문에 짧은 시간(3시간) 내에 one-stop으로 검사를 종료할 수 있는 큰 장점을 가지게 된다. 그러므로 이 검사법은 ischemic heart disease의 one-stop evaluation에 있어서 유용한 protocol로 보여진다.

  • PDF

Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress

  • Lihua Yu;Xiaofeng Tao;Xu Dai;Ting Liu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.97-105
    • /
    • 2021
  • Objective: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease. Materials and Methods: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded. Results: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm. Conclusion: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.

심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하 (Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA)

  • 공은정;조인호;천경아;원규장;이형우;박종선
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

CT Assessment of Myocardial Perfusion and Fractional Flow Reserve in Coronary Artery Disease: A Review of Current Clinical Evidence and Recent Developments

  • Chun-Ho Yun;Chung-Lieh Hung;Ming-Shien Wen;Yung-Liang Wan;Aaron So
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1749-1763
    • /
    • 2021
  • Coronary computed tomography angiography (CCTA) is routinely used for anatomical assessment of coronary artery disease (CAD). However, invasive measurement of fractional flow reserve (FFR) is the current gold standard for the diagnosis of hemodynamically significant CAD. CT-derived FFRCT and CT perfusion are two emerging techniques that can provide a functional assessment of CAD for risk stratification and clinical decision making. Several clinical studies have shown that the diagnostic performance of concomitant CCTA and functional CT assessment for detecting hemodynamically significant CAD is at least non-inferior to that of other routinely used imaging modalities. This article aims to review the current clinical evidence and recent developments in functional CT techniques.

조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가 (Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques)

  • 남지호;기용간;김동원;김원택
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.26-33
    • /
    • 2007
  • 목 적: 좌측 조기유방암으로 보존수술 후 2차원 또는 3차원 모의치료를 통해 방사선치료를 받은 환자들에서 SPECT (single photon emitted computerized tomography) 영상을 이용하여 심근관류결손의 부위와 빈도를 비교 평가하고자 하였다. 대상 및 방법: 2002년 1월부터 2003년 8월까지 AJCC 병기 T1-T2N0M0인 좌측 조기유방암으로 진단되어 외과에서 보존수술 및 화학요법 후 방사선치료를 시행하였던 32명의 환자들을 대상으로 하였다. X선 투시기를 이용한 2차원 모의치료를 통해 방사선치료를 받은 환자들과 컴퓨터단층촬영 기반의 3차원 모의치료 방법을 이용했던 환자들을 구분하여 연구를 진행하였다. 이들을 대상으로 최소 3년 이상의 추적관찰 기간 후에 technetium-99m-sestamibi gated perfusion SPECT를 시행하여 각 군에서의 심근관류결손의 부위와 빈도를 비교 평가하였고, 각 환자들에서의 심벽의 운동상태와 좌심실의 박출량을 측정하여 분석하였다. 또한 모의치료 과정에서 방사선에 피폭되는 심장영역을 각 군에서 측정하여 심근관류결손과의 상관관계를 알아보았다. 결 과: SPECT 영상 결과, 심근관류결손이 확인된 경우는 전체 32명의 환자 중 11명(34.4%)이었다. 2차원 모의치료를 받은 15명의 환자 중 7명(46.7%)에서, 3차원 모의치료를 받은 17명의 환자 중 4명(23.5%)에서 관류결손이 발견되었는데, 3차원 모의치료를 이용한 환자들에서 심근관류결손의 빈도가 통계적으로 유의하게 낮았다(p=0.0312). 심근관류결손이 확인된 11명 중, 심첨부 결손을 보인 경우가 10명으로 대부분을 차지했다. 심벽의 운동상태와 심실박출량은 모두 정상이었으며, 방사선 조사야에 포함된 심장영역은 3차원 모의치료 군에서 보다 작았으나 양군에서의 심근관류결손과의 통계적 유의성은 확인할 수 없었다. 결 론: 저자들은 이번 연구를 통해 좌측 조기유방암 환자에서 보존수술 후 방사선치료 시 전산화단층촬영 모의치료기를 이용한 3차원 모의치료 방법을 이용하면 심근에 대한 조사용적을 줄일 수 있어 심근관류결손의 빈도를 낮출 수 있음을 확인하였다. 그러나 심근관류스캔상의 결손과 향후 임상적인 허혈성 심장질환으로의 발전 또는 이로 인한 사망률의 증가와의 연관성은 장기간의 추적관찰과 전향적 임상연구를 통해 확인할 필요가 있겠다.

관상동맥질환의 예후 및 위험도 평가 (Assessment of Prognosis and Risk Stratification in Coronary Artery Disease)

  • 임석태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권3호
    • /
    • pp.222-228
    • /
    • 2009
  • Risk stratification and assessment of prognosis in patients with known or suspected CAD is of crucial important for the practice of contemporary medicine. Noninvasive testing such as myocardial perfusion scintigraphy, coronary artery calcium scoring or CT coronary angiography is increasingly being used to determine the need for aggressive medical therapy and to select patients for catheterization. The integrated anatomic and functional information may provide more additional information for the cardiologist or other clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The development of SPECT/CT or PET/CT hybrid systems is therefore of important value for the nuclear cardiology.

13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가 (Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT)

  • 도용호;이홍재;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.69-75
    • /
    • 2014
  • 최근 진단 분야에서 PET/CT는 종양학 분야는 물론 심장, 신경 등 여러 가지 분야에서 널리 활용되고 있다. 그 중 심장 분야에서 $^{13}N-NH_3$ 심근 관류 PET/CT는 MBF를 이용한 절대 심근 관류의 측정이 가능하며 심근 관류 SPECT에 비하여 공간 분해능과 대조도가 우수하고 CT를 이용한 보다 정확한 감쇄 보정이 가능하다는 장점을 가지고 있다. 본 연구에서는 $^{13}N-NH_3$ PET/CT 검사 시 각 재구성 방법에 따른 정량적 심근 관류, 반정량 심근 관류 지표의 변화와 image quality의 변화를 비교하였다. 2013년 1월부터 11월까지 서울대학교병원에서 $^{13}N-NH_3$ PET/CT 검사를 시행받은 14명(평균연령 $60.24{\pm}7.21$세, 평균 몸무게 $71.54{\pm}7.43kg$, 남자 8명, 여자 6명)의 데이터를 분석하였다. 안정기, 부하기 각 10분 listmode scan의 data를 이용 동적, 정적 영상을 FBP, iterative2D, Iterative3D, TrueX의 재구성 방법을 이용하여 재구성하였다. 안정기, 부하기의 각 동적 영상을 이용하여 MBF에서 재구성 방법에 따른 RCA, LAD, LCX의 각 territory 별 심근관류와 global, reserve (stress/rest)값을 비교하였다. 또한 정적 영상을 이용 QPS에서 각 재구성 방법에 따른 extent와 TPD 를 비교하였으며 재구성 방법 별 정적 영상의 snapshoot을 제작하여 영상의 해상력과 노이즈, 판독의 용이성을 기반으로 핵의학과 판독의 5명의 blind test를 시행하였다. 각 재구성 방법에 따라 vendor에서 권고 되는 iterative2D 대비 정량적 심근 관류의 CFR은 최소 -18.68% (P=0.0002)에서 최대 7.91% (P<0.0001)의 변화를 보였으며, 반 정량적 지표들은 안정기에서 extent는 최소 -0.86%p (P=0.1953)에서 최대 5.36%p (P<0.0001), TPD는 최소 -0.57%p (P=0.2053)에서 최대 4.36%p (P<0.0001), 부하기에서 extent는 최소 1.93%p (P=0.4275)에서 최대 5.43%p (P=0.0003), TPD는 최소 1.57%p (P=0.4595)에서 3.93%p (P<0.0001) 증가된 값을 보였다. 영상의 해상력과 노이즈, 판독의 용이성을 기반으로 핵의학과 판독의 5명의 blind test에서는 FBP로 재구성된 영상이 최하위로 평가 되었으며 TrueX, iterative2D, iterative3D 순으로 평가되어 iterative3D로 재구성된 영상이 판독 시 가장 우수한 영상을 평가되었다. 각 병원은 장비에 따른 각 재구성 방법에 의한 정량적 심근 관류의 변화, 반 정략적 지표들의 과대 또는 과소평가되는 정도를 확인하고 병원 장비의 실정에 적합한 동적, 정적 재구성 방법을 확립하여 진단에 보다 유용하고 정확한 심근 관류 값을 제공하여야 할 것이다.

  • PDF