• Title/Summary/Keyword: Musculoskeletal System

Search Result 597, Processing Time 0.023 seconds

Report on the improvement of the in vitro and specimen reception environment system (핵의학과 검체 접수 환경시스템의 개선사례 보고)

  • Kim, Jung In;Kang, Mi Ji;Kim, Na Kyung;Park, Ji Sol;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2021
  • Purpose Sample reception environment system in nuclear medicine has not changed much compared to 20 years ago. When preparing sample for in vitro test, there was no significant change because the test was carried out by generating an own specimen from the parent specimen. In this study, We would like to introduce a method that automatically removes the sample cap using the automated decapper equipment and enables automatic reception at the same time. In addition, including a provisional reception system. Materials and Methods In 2019, it was intended to get a device that automatically removes the cap of a patient's blood sample. This equipment is the same as the equipment used in the Department of Laboratory Medicine (Vacuette Ⓡ Unicap Belt Decapper, Greiner bio-one, Austria). However, the purchase was delayed due to differences in tube size, budget, and space. In January 2020, we borrowed domestic automatic decapper equipment and modified it to suit our laboratory environment. After 9 months, we were able to introduce a system that automatically removes the lid of a patient's blood sample and at the same time automatically accepts the test. And, through the provisional reception system, it was possible to know the arrival of the specimen in a short time. Results With the use of an automatic decapper device, the sample cap was automatically removed, and the reception proceeded at the same time. So, it was very efficient at work because it shortened the sample preparation time by about 20 minutes. In addition, it was possible to prevent the examiner's musculoskeletal disorders caused by repeated wrist use. After using the provisional reception system, patients were able to be discharged quickly, and the number of phone calls to confirm the arrival of samples was reduced. Conclusion Most hospitals have about four employees in the nuclear medicine in vitro laboratory. It is effective to use automatic decapper equipment and a provisional reception system for organizations that perform work with the minimum number of personnel.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

Development of and Evaluation Tool for the Quality of Patient Care in Musculo-skeletal Disorder (${\cdot}$ 골격장애 환자의 간호질 평가 도구 개발)

  • Choi, Soon-Ook;Kim, Moon-Sil
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.338-348
    • /
    • 1995
  • We need to continuously evaluate for nursing quality and the outcome to reflect nursing, to repair and improve of nursing. The first problem for nursing quality improvement is development of evaluation tool for the quality of nursing care. We need a system for quality assurance evaluation that is, development and framework of evaluation tool for nursing care quality. The purpose of this study was attempted to develop an evaluation tool for the quality of nursing care in musculoskeletal disorder patients. The approach method of nursing quality for the development of the tool in this study was process evaluation framework. The study were devided dvelopment process and reliability, validity verification process. The subjects of development process of this tool are three nursing export groups, and the subject of reliability, validity verification process are 20 samples of two university hospital in seoul, who were within discharge 3 months after admission treatment in musculo-skeletal disorder. Data for this study was collected from March 10 to April 13, 1995. The development process of the tool were as follows : 1. Make preliminary list of the tool by focal group were constituted 12 clinical nurses. 2. Modify and add preliminary list by 4 nursing expert panel. 3. Calculate content validity of the tool by 25 nursing expert panel of judge. 4. Verify reliability and validity of the tool. 5. Finalize an evaluation tool for the quality of the nursing care in musculo-skeletal disorder. The results of this study were as follows : 1) Development an evaluation tool for the quality of nursing care in musculo-skeletal disorder. (1) The evalution tool of this study was developed 5 standards, 33 criterias and 133 indicators. (2) 5 standards were divided according to Nursing Process. from standard 1 to standard 5, involved criterias were each 6(18%), 3(9%), 3(9%), 15(46%), 6(18%). 2) Verify reliability and validity of the tool. (1) Score of adequate degree for content validity of 33 criterias and 133 indicators were every average 2.82. (2) Inter-rater reliabilities(consentaneity score) of the tool by pearson correlation coefficient between three raters were : r=.7506, r=.8934, r=.6695. and Inter-rater reliabilities by single-facet crossed design were : r=.7464. (3) The alpha coefficient relating to internal consistency was .8524 over all 30 items of 33 criterias of developed tool. (4) Score of the quality of nursing care following to generaal characteristics of this study subjects were stastically significant differences according to educational level (F=2.93, p=.029)and diagnosing classification (F=2.50, p=.042). Through this study, I'm sure that the developed tool for the quality of patient care in musculo-skeletal disorder will show the way of more improvement of the quality of nursing care and effective nursing interventions.

  • PDF

Chronic Physical Comorbidities and Total Medical Costs in Patients with Schizophrenia (조현병 환자의 동반 만성신체질환 현황 및 총 의료비용에 관한 연구)

  • Lee, Sang-Uk;Lee, Ye-rin;Oh, In-Hwan;Ryu, Vin;Goo, Ae-Jin;Kim, You-Seok
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.26 no.1
    • /
    • pp.26-34
    • /
    • 2018
  • Objectives : This study tried to explore the prevalence of chronic physical diseases in patients with schizophrenia and its effects on total medical costs. Methods : The Health Insurance Review and Assessment Service data in 2014-2015 was employed. Only the injuries and diseases, identically diagnosed 3 times or more as a major or minor injury and disease, were classified into chronic physical diseases to improve data accuracy. Total medical costs included out-of-pocket and insurer's costs from health care system perspective. Results : It was shown that 24.5%, 17.3% and 23.4% of schizophrenia patients had one, two and three or more chronic physical diseases, respectively. There was a high prevalence of not only metabolic, but also musculoskeletal, diseases in those patients. The amount of 2015 total medical costs of patients with schizophrenia in 2014 was about 1.08 trillion won. The factors affecting the costs included sex, age, number of chronic physical diseases, and health insurance status. Conclusions : It is considered that clinical practice guidelines based on personal diseases may not sufficiently solve the problems for comorbidities in schizophrenia patients. Accordingly, it should be required to develop models for new types of medical systems capable of treating and caring varied illnesses at the same time.

Effect of heel Heights of shoe on Muscle Activation of Lower Extremity on the Rocking Surface in older Women (흔들림이 있는 표면에서 여성 노인의 신발 굽 높이가 하지 근육 활성도에 미치는 영향)

  • Kim, Kyoung;Cho, Yong-Ho;Cha, Yong-Jun;Song, Byung-Seop
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.316-322
    • /
    • 2008
  • The purpose of this study was to investigate muscle activation of lower extremity such as rectus femoris, tibialis anterior and soleus according to 0cm(bare foot), 4cm and 7cm heel height of shoe on the rocking surface in older women. 20 older women who did not have any lower musculoskeletal and neurological disorders in the past were participated in this study. Each subject was standing for 15 seconds on the level 8 of Biodex Stability System (BSS) while wearing 4cm and 7cm heel height shoes including bare foot. Electromyography was used to measure muscle activation of lower extremity, and the muscle activation was expressed as a percentage of maximal voluntary isometric contraction (% MVIC). We measured % MVIC of three muscles during 5 seconds except for the first 5 seconds and last 5 seconds. SPSS 12.0 program was used for this study. Repeated one-way analysis of variance(ANOVA) was performed to compare the significant difference among the muscles of lower extremities according to heel heights of shoe on the rocking plate. % MVIC of each muscle such as rectus femoris, tibialis anterior and soleus regarding heel heights of shoe had statistically significant differences (p<0.05). The results of contrast test were as follows; 1) % MVIC of rectus femoris had significant differences between barefoot and 4cm, and barefoot and 7cm. 2) % MVIC of tibialis anterior had significant differences between barefoot and 4cm, barefoot and 7cm, and 4cm and 7cm. 3) % MVIC of soleus had significant differences between barefoot and 7cm, 4cm and 7cm. The results indicate that all commonly responsive muscle on the conditions of barefoot, 4cm, and 7cm shoe height on the rcoking surface is tibialis anterior muscle. We found out that the more heels of shoe high, the more muscle activation increases. High-heeled shoes above 7cm remarkably increase the muscle activation of lower extremity and may result in muscle fatigue. Thus, these shoes may summate risk factors of falls in older women. We can acknowledge that the heels above 4 cm affect each muscle activation in lower extremity on the rocking surface.

The Effects of Pulsator Washing Machine on Joints Torques and Muscles Strengths Considering Height of Outside Machine and Depth of Inside Drum for Average Height Users (투입구 높이 및 내부 드럼 깊이를 고려한 펄세이터 세탁기 사용시 평균신장 사용자의 관절 토크 및 근력에 미치는 영향)

  • Kim, Seong Guk;Cho, Young Kuen;Lee, Nam Gi;You, Joshua Sung Hyun;Lim, Dohyung;Kim, Han Sung;Ko, Chang-Yong
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.184-193
    • /
    • 2012
  • Many studies have reported that housework done using household appliances may affect biomechanical characteristics of the musculoskeletal system. The purpose of this study was to investigate the effects of housework done using a pulsator washing machine on joints and muscles. We calculated joint torques and muscle strengths on the basis of an experimental/virtual three-dimensional motion analysis for six healthy females using the pulsator washing machine at different heights (H) and depths (D) of the inside drum (H (mm){\times}D (mm), Trial1: $962.5{\times}609.4$, Trial2: $962.5{\times}624.4$, Trial3: $982.5{\times}644.4$, Trial4: $995.5{\times}642.4$, Trial5: $1015.5{\times}677.4$). The joint torques and muscle strengths tended to be considerably different during torso flexion in the sagittal plane for all the trials. The maximum joint torques for the thoracic vertebra, left ankle, and right shoulder measured in Trial4 were significantly higher than those measured in the other trials (p < 0.05); in addition, those for the thoracic vertebra and both ankles measured in Trial5 were significantly higher than those measured in the other trials (p < 0.05). The maximum muscle strengths for the left trapezius muscle and both tibialis anterior muscles measured in Trial5 were significantly higher than those measured in the other trials (p < 0.05). These results indicate that housework done using a pulsator washing machine may affect joint torques and muscle strengths, and these effects are dependent on the height and/or depth of the inside drum of the pulsator washing machine.

The Effect of Using Standing Step Condition on Biomechanical Variables during Jab in Boxing (복싱 잽(jab) 동작 시 제자리 스텝의 사용이 운동역학적 변인에 미치는 영향)

  • Lee, Seong-Yeol;Kwon, Moon-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.232-240
    • /
    • 2020
  • The purpose of this study was to analyze the effect of using standing step condition on biomechanical variables during jab in boxing. For this purpose, eight orthodox type college boxers(age = 20.38±0.52 yrs, height = 172.38±5.80 cm, body mass = 63.45±8.56 kg, career = 6.00±1.07 yrs) who without injury to the musculoskeletal system participated in the experiment over the last year. In order to verify the effect of biomechanical variables using standing step during jab in boxing, the paired t-test (α = .05) statistical method was used. First, W.S(with-step) showed a greater impact force than N.S(non-step), and muscle activity was analyzed to be low. Second, it was analyzed that the pelvis and foot segments move faster because W.S affects the velocity of the anterior segment of the human body. Third, the rotational movement of the pelvis was faster in W.S. Fourth, W.S was analyzed to have greater ground reaction force in the anterior caused by the right and left foot than N.S. Through this, it was found that the use of the standing step during jab increases the ground reaction force the velocity and rotational movement of the human segment. Therefore, it was confirmed that it allowed a faster and more agile movement, and thus produces a greater impact force with relatively less muscle activity. Therefore, in order to effectively deliver a greater impact force to the opponent during the jab, it was effectively analyzed to accompany the standing step.

The Effects of Speed Variations in Treadmill Training on Thickness of Lower Extremity Muscles (속도가 다른 트레드밀 훈련이 다리 근두께에 미치는 영향)

  • Park, Chi-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.363-370
    • /
    • 2016
  • The purpose of this study was to determine the effects of speed variations in treadmill training on the thickness of lower extremity muscles. A total of 36 university students were divided into three groups: MVTG (n=12), HVTG (n=12), and ATG (n=12). Subjects in MVTG underwent treadmill training with their own average speed; those in HVTG underwent treadmill training with 130% speed of their own average speed; and those in ATG underwent treadmill training with alteration of speed, between 100% and 130% of their own average speed. Treadmill training was performed for 60 minutes a day, three times per week, for a total of 6 weeks. Ultrasonography was used to compare the muscle thickness between rectus femoris, vastus lateralis, gastrocnemius, and tibialis anterior. The result was as follows: The rectus femoris, vastus lateralis, and gastrocnemius were significantly increased after the training period, and they also were statistically significant in interaction. Moreover, tibialis anterior was also significantly increased. Therefore, compared to the average-speed treadmill training, speed variations had a greater effect on thickening the lower extremity muscles. In the near future, we will conduct a study applying the findings from this study in a rehabilitation program for patients with gait disturbance due to nervous or musculoskeletal system disease.

Systematic Review of Hominis Placenta Pharmacopuncture in English and Korean Literature

  • Ryoo, Dek-Woo;Kim, Hong-Guk;Kim, Sung-Jin;Baek, Seung-Won;Jeong, Seong-Mok;Yoon, Jin-Young;Lee, Chang-Hee;Goo, Bon-Hyuk;Kim, Min-Jeong;Park, Yeon-Cheol;Baek, Yong-Hyeon;Nam, Sang-Soo;Seo, Byung-Kwan
    • Journal of Acupuncture Research
    • /
    • v.34 no.4
    • /
    • pp.153-158
    • /
    • 2017
  • Background: Hominis placenta (HP) is used in Korean medicine to tonify qi and blood, and enrich yin and tonify yang. HP has been reported to have therapeutic effects. Methods: A survey of international and Korean electronic databases was conducted using the search terms "hominis placenta pharmacopuncture" and "hominis placenta extract". The search was limited to material published up to May 31, 2017. Results: A total of 83 studies were included in this systematic review: 50 were clinical studies, 25 were basic studies, and 8 were other types of study. Among clinical studies, the most frequently treated disease groups were musculoskeletal diseases and nervous system diseases. In vitro studies were conducted mainly on anti-inflammatory, analgesic, and anti-cell necrosis models. Most of the in vivo studies were performed in rheumatoid arthritis or diabetic complications models. Conclusion: HP pharmacopuncture has effects in the treatment of various diseases. Further large-scale randomized controlled trials are needed to improve the level of evidence for HP pharmacopuncture. It would be helpful if future in vitro and in vivo studies could identify the mechanism of action of HP pharmacopuncture.

A Preliminary Study on Development and Evaluation of Home Health Care Nurse Clinical Practice Program -Focused on Postoperative Orthopedic Patients- (가정간호사 임상실무 훈련프로그램 개발과 평가를 위한 사전 연구 -정형외과 수술 환자를 중심으로-)

  • 서영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.1
    • /
    • pp.15-32
    • /
    • 1996
  • The clinical practice program for home care nurses was implemented in June 1994, to help to set up a hospital-based home care system in the Kwangju City area as a collaborative work between the Department of Orthopedic Surgery at Chunnam University Hospital and Chunnam University School of Nursing. Under the developed clinical practice strategy, the eight week training was given to five licensed home care nurses who had completed Part I and II of the home health care nursing practicum from June 1994. The purpose of this descriptive evaluation study was to identify the effectiveness of the clinical practice program for home care nurses specialized in the area of patient care for people with musculoskeletal function impairment. As a method in data analysis, data triangulation was used in the five home care nurse case evaluations. The variety of data analyzed include confidence score by home care nurse self-evaluation, patient and family member satisfaction scores, and competency score by preceptor evaluation. The study findings revealed that an increase rate in nursing performance didrate necessarily coincide with an increase not in competency score and also, not with the patient /family member satisfaction scores. And an order derived from the clinical performance scores of five home care nurses corresponded to those from three measurements-competency score, patient satisfaction score, and family member satisfaction score. However, it differed from the order associated with the confidence score. Consistency derived from the three objective evaluation methods may lead to the possibility that the level of competency measured by educator can be further explained by the levels of patient/family member satisfaction. The salient finding of this study was that, in case of nurse A who have had little clinical experience in the orthopedic patient care, there was a significant increase in the level of confidence and competency in subscale of professional skill with the home care clinical practice. Therefore, the effect of the clinical practice program would be successful for nurses who have had little experience in the area of specialization. The study results suggest that there might be some time difference in the development of cognitive sense (confidence) in performance and actual clinical performance (competency). In future research, relationships between the confidence and competency score, and between the confidence score and the patient satisfaction score should to be measured in different time frame to achieve a better explanation power of the study outcome.

  • PDF