• Title/Summary/Keyword: Municipal wastewater sludge

Search Result 108, Processing Time 0.022 seconds

Status, Trend and Strategy on Municipal Wastewater Management in China

  • Wang, Baozhen;Wang, Lin;Liu, Shuo;Wang, Li;Wang, Zheng
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.47-60
    • /
    • 2007
  • The rapid development of economy in China at the expense of consuming huge amount of energy and resources, water resource in particular, which has resulted in the production and discharge of increasing amount of wastewater to the water environment. In order to effectively control the increasing water pollution trend, the State Council has stipulated that all the cities with population over 500,000 should reach wastewater treatment rate of 60% by 2005, and all the cities should reach the rate of 60% by 2010, of which Capital Beijing and all the province capital cities and important tourism cities should reach 70% then. By the end of 2005, of the 661 cities in China, 393 have built and operated municipal wastewater treatments with a total number of 790 sets, total treatment capacity of $80.91{\times}106m^3/d$ and total treatment rate of > 48%. Other 73 cities have started the construction of municipal wastewater treatment plants, and other 168 cities have started to prepare, planning and design of wastewater treatment plants. Most of municipal wastewater treatment plants in big cities in China operate normally and perform well with good quality of effluent in terms of wastewater treatment train, but the sewage sludge treatment is usually poor with big problems. It has been found that the small scale WWTPs using activated sludge process in the towns are usually operated and maintained abnormally because of lack of fund, skilled operators and energy. It is therefore suggested that the small scale MWWTPs in small cities and towns adopt appropriate technologies, of which the most available ones are multi-stage ponds, constructed wetlands and the combination of them for further purification and reuse of treated wastewater.

  • PDF

Separation of Inorganic Sludge and MAP from Municipal Wastewater Sludge Using Hydrocyclone (습식 사이클론을 이용한 하수슬러지내 무기성분 및 MAP 분리)

  • Lee, Dong-Woo;Bae, Kang-Hyeong;Cho, Kun-Sang;Kim, Sung-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.135-142
    • /
    • 2014
  • The performance of inorganic sludge separation system is evaluated. Anaerobic digester effluent sludge is used for feed sludge of this system and hydrocyclone is used for inorganic sludge separation. For phosphorus removal and recovery $MgCl_2$ is pumped into MAP growth tank, a component of inorganic sludge separation system. Using this system inorganic sludge which contained less than 40 % of organic matter can be discharged stably and the maximum amount of separated inorganic sludge is 13.4 % of influent sludge based on dry solid. The amount of phosphorus recovered as MAP(as P) is 16.7 % to influent T-P.

Respirometry for the Assessment of Organics Biodegradability in Municipal Wastewater: I. Respirometry (호흡률법에 의한 하수의 생분해 특성 평가: I. 호흡률법)

  • Kim, Dong Han;Kim, Hee Jun;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Organics may be divided into biodegradable and nonbiodegradable fractions on the basis of biodegradability. Biodegradable organics may be subdivided into readily and slowly biodegradable fractions. As this biodegradability of organics in municipal wastewater has a great influence on the efficiency of a biological nutrient removal process, it has been assessed by respirometry. The respirometer, which consisted of a respiration chamber and a respiration cell, was used to measure the respiration rate of biomass utilizing the readily biodegradable organics. The readily biodegradable organics are about 10% of the COD in municipal wastewater. The adequate ratio of wastewater to sludge volume and the concentration of sludge are required in measuring the respiration rate due to the readily biodegradable organics. By using a biochemical oxygen demand test, the slowly biodegradable organics including biomass are estimated about 66% of COD. The soluble inert organics are about 11% of COD. On the basis of mass balance, the particulate inert organics are estimated about 13% of COD.

Analysis of the Activated Sludge of a Municipal WWTP by Several Bio-Parameters

  • Cho Sun-Ja;Jung Yong-Ju;Park Tae-Joo;Lee Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.14 no.9
    • /
    • pp.811-815
    • /
    • 2005
  • The activated sludge from the aeration basin of the Su-yeong municipal wastewater treatment plant which has operated by a standard activated sludge process in Busan, Korea was investigated during April 2004 and January 2005 with several bio-indicators. The number of bacteria and fungi per gram of dry weight of MLSS were estimated to be $3.1\times10^6\sim1.5\times10^8\;and\;l.1\times10^3\sim1.1\times10^5$ colony forming units, respectively, by the plate agar method. By cultivation-independent methods, such as 4',6-diamidino-2-phenylindole stain and fluorescence in situ hybridization, the ratio of eubacteria to the entire biomass was evaluated by more than $80\%$ (v/v). The ratio of ammonia-oxidizing bacteria and nitrite-oxidizing bacteria to the total eubacteria was detennined to be $7.0\sim9.8\%\;and\;3.3\sim6.2\%$ without heavy variation in spite of a period of relatively low temperature in the basin. It would be expected that the nitrification would occur or at least co-exist throughout the year in the sludge of many municipal WWTP with influents that contain the sufficient nitrogen sources although the WWTP does not have any specialized processes for the removal of nitrogen.

Effect of Digestion Temperature on the Solid-Liquid Separation Characteristics of Anaerobically Digested Municipal Sewage Sludge (도시하수슬러지의 혐기성소화시 고액분리 특성에 미치는 소화온도의 영향)

  • Han, Jang Woon;Chang, Duk;Kim, Sung Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Laboratory experiments were conducted to investigate the effect of digestion temperature on the settleability and dewaterability of anaerobically digested sludge. The digesters were operated at a hydraulic retention time of 20 days with a loading rate of 0.63~0.66kg volatile solids per cubic meter per day at the temperature of $35^{\circ}C$ and $55^{\circ}C$. A mixed primary and secondary municipal sludge was used as a feed. The interface height of the sludge during settling test was recorded to identify settleability. As a measure of dewaterability of the sludge, specific resistance and capillary suction time were also measured with and without chemical conditioning. Higher digestion efficiency was obtained at $55^{\circ}C$ than $35^{\circ}C$. However, the settleability and dewaterability of the sludge at $35^{\circ}C$ were quite higher than those of the sludge digested at $55^{\circ}C$. The optimum dosages of ferric chloride for sludge conditioning were 0.4% and 0.6% at $35^{\circ}C$ and $55^{\circ}C$, respectively. The filtrate COD of the sludge digested at $55^{\circ}C$ was higher than at $35^{\circ}C$, which means that poor dewaterability of the sludge result in high filtrate COD.

  • PDF

Removal of Nitrogen and Phosphorus from Municipal Wastewater by a Pilot-scale BNR Process (파이롯트 규모의 BNR 공법에 의한 도시하수의 질소 및 인 제거)

  • Kim, Young-Chur
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.589-599
    • /
    • 2007
  • This study was conducted to investigated the removal efficiency of BOD and nutrient for the treatment of low strength municipal wastewater by a biological nutrient removal system. In this experiment, the effect of operating parameter including HRT of 7.0hr, BOD/TN ratios of 2.62~4.08, internal recycle of 50~300%, and return sludge of 50~100%, were studied during winter season. Efficiencies of organic matter and T-P removal and denitrification were not significantly affected by the change of temperature in winter season. However, the specific nitrification rate and nitrification efficiency decreased at low temperature. Besides, denitrification efficiencies increased with increasing BOD/TN ratios. It was also found that the internal recycle and return sludge ratio below 50% is required for the effective denitrification of low strength municipal wastewater. With operating mode 4 of the optimum, the effluent BOD, T-N and T-P concentration were obtained to average 5.8, 14.6, and 0.84 mg/L, respectively. The temperature-activity coefficient (${\theta}$) of specific nitrification rate, specific denitrification rate and specific phosphorus uptake rate were obtained 1.044, 1.017, 1.028, respectively.

The Nitrogen and Phosphorus Removal of UNR Process Using Sludge Carbon Source (슬러지 탄소원을 주입한 UNR공정의 동절기 질소, 인 처리효율)

  • Kim Young Gyu;Kim In Bae
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.93-97
    • /
    • 2002
  • The aim of this study was to evaluate on the removal effect of total nitrogen and phosphorus with municipal wastewater in ultrasonic nutrient removal (UNR) process using ultrasonic sludge carbon source. The removal efficiency for total nitrogen was 44.2% at biological nutrient removal (BNR) process, 50.8% at UNR process. The removal efficiency for total phosphorus was 45.6% at BNR process, 46.2% at UNR process. The removal of nitrogen was effectively influenced by ultrasonic sludge carbon source.

Enhancement of Sewage Sludge Dewaterability by H2O2-Oxidation and Mixing with Paper Sludge (하수슬러지 탈수성 개선을 위한 과산화수소 처리 및 제지슬러지 혼합탈수에 관한 연구)

  • Hwang, Sun-Jin;Eom, Hyoung-Choon;Jang, Hyun-Sup;Jang, Kwang-Un;Kwon, Jae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.508-514
    • /
    • 2004
  • Industrial and municipal wastewater treatment plants produce large amounts of sludge cakes for final disposal. This problem is an inevitable drawback inherent to the activated sludge process. Both the reduction of the amount of sludge produced and improvement of its dewaterability are presently very important issue also in Korea. So many pre-treatment processes have been developed in order to improve sludge dewatering efficiency. In this study the effects of hydrogen peroxide and paper sludge mixing processes were considered as reasonable alternatives to enhance sludge dewaterability. The CST of sludge was significantly decreased, and dewaterability improved by hydrogen peroxide oxidation treatment. The optimum dosage of hydrogen peroxide was proved to be 10mg/g-TS (when TS of sludge was 2%) with the conditions of pH 4 and only 1~2 minutes of reaction time. The mixing of paper sludge with sewage sludge was turned out to be very effective in reduction of sludge cake; 30% of sludge cake reduction was accomplished. Optimum mixing ratio of paper sludge was about 30%(v/v). This process also could save 25% of polymer to be required. These two alternatives are somewhat realistic, but it was concluded that paper sludge mixing process will be the best choice.

Feasibility Studies on Anaerobic Sequencing Batch Retractor for Sludge Treatment

  • Duk Chang;Joo
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.125-136
    • /
    • 1992
  • Digestion of a municipal wastewater sludge by the anaerobic sequencing batch reactor (ASBR) was investigated to evaluate the performance of the ASBR process at a critical condition of high-solids-content fined. The reactors were operated at an HRT of 10 days with an equivalent loading rate of 0.8-1.5 gVS/L/d at 35$^{\circ}C$ The main conclusions drawn from this study were as follows: 1. Digestion of a municipal wastewater sludge was possible using the ASBR in spite of high concentration of settleable solids in the sludge. The ASBRS with 3- and 4-day cycle period showed almost identical high digestion performances. 2. No adverse effect on digestion stability was observed In the ASBRS in spite of withdrawal and replenishment of 30% or 40% of liquid contents. A conventional anaerobic digester could be easily converted to the ASBR without any stability problem. 3. Flotation thickening occurred in thicken step of the ASBRS throughout steady state, and floating bed volume at the end of thicken period occupied about 70% of the working volume of the reactor Efficiency of flotation thickening in the ASBRS could be comparable to that of additional gravity thickening of a completely mixed digester. 4. Solids were accumulated rapidly in the ASBR during start-up period. Solids concentrations in the ASBRS were 2.6 times higher than that in the completely mixed control reactor at steady state. Dehydrogenase activity had a strong correlation with the solids concentration. Dehydrogenase activity of the digested flu형e in the ASBR was 2.9 times higher than that of the flu형e in the control reactor, and about 25 times higher than that of the subnatant in the ASBR. 5. Remarkable increase in equivalent gas production of 52% was observed at the ASBRS compared with the control reactor in spite of similar quality of clarified effluent from the ASBRS and control reactor. The increase in gas production from the ASBRS was believed to be combined results of accumulation of microorganisms, higher driving force applied, and additional long-term degradation of organics continuously accumulated.

  • PDF

Flotation Characteristics of Activated Sludge by Micro-bubbles (미세 기포에 의한 활성슬러지의 부상특성)

  • Kim, Seong-Jin;Kang, Byoung-Jun;Park, Sang-Wook;Lee, Jae-Wook;Jung, Heung-Joe;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.501-507
    • /
    • 2006
  • Dissolved air flotation (DAF) has been well known for the gravity separation process. The solids to be separated are transferred from the water body to the water surface using micro-air bubbles. DAF has also been used for enhancing solids-liquid separation of industrial and municipal wastewater by adding a its unit parallel to a sedimentation unit to reduce the hydraulic loading in the sedimentation clarifier. This study was to investigate flotation characteristics of activated sludge by the recent DAF technique without chemical agents. In addition, the effect on temperature in flotation of activated sludge and the thickening degree of activated sludge were studied.