• Title/Summary/Keyword: Multislice

Search Result 25, Processing Time 0.018 seconds

Target motion analysis of the respiratory gated guided radiotherapy in liver cancer patients using 4D-CT (4D-CT와 호흡동조시스템을 이용한 간암 환자의 방사선치료 표적 움직임 분석)

  • Dong, Kyung-Rae;Park, Byung-Soo;Kim, Sae-Sark;Kweon, Dae-Cheol;Goo, Eun-Hoe;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.63-68
    • /
    • 2010
  • The ultimate goal of radiation treatment is to use enough radiation dosage in order to examine a tumor while protecting normal tissue. Respiratory guided radiotherapy is being clinically implemented to examine a given stabilized area in order to compensate for the problems of patient breathing. This study investigates the effects of breathing movements on 40 patients with liver cancer through the actual radiation therapy plan using 4D-CT and respiratory guided radiotherapy using RPM. Using a commercial RPM respiratory gating system 4D-CT, we acquired 4D CT on multislice helical CT scanners that use different approaches to 4D CT image reconstruction. The results from analyzing forty patients according to age and direction showed no relationship between gender and transition change. The mean left-right, anteroposterior, and craniocaudal total movements were $3.19{\pm}1.29$, $5.44{\pm}2.07$, and $12.54{\pm}4.70$ mm, respectively. Changes were the largest with CC directions and as patients advanced in age, movements were larger. Therefore, as changes occur in treatment areas because of movements caused from breathing, respiratory gating system is put into operation to revise movement and can increase the radiotherapeutics effects in treating liver cancer.

Practical Considerations of Arterial Spin Labeling MRI for Measuring the Multi-slice Perfusion in the Human Brain (스핀 라벨링 자기공명영상을 이용한 사람 뇌에서의 뇌 관류영상의 현실적 문제점을 향상 시키는 방법 연구)

  • Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • In this work practical considerations of a pulsed arterial spin labeling MRI are presented to reliable multi-slice perfusion measurements In the human brain. Three parameters were considered in this study. First, In order to improve slice profile and Inversion efficiency of a labeling pulse a high power Inversion pulse of adiabatic hyperbolic secant was designed. A $900^{\circ}$ rotation of the flip angle was provided to make a good slice profile and excellent Inversion efficiency. Second, to minimize contributions of a residual magnetization be4ween Interleaved scans of control and labeling we tested three different conditions which were applied 1) only saturation pulses, 2) only spotter gradients, and 3) combinations of saturation pulses and spotter gradients Applications of bo4h saturation pulses and spoiler gradients minimized the residual magnetization. Finally, to find a minimum gap between a tagged plane and an imaging plane we tested signal changes of the subtracted image between control and labeled Images with varying the gap. The optimum gap was about 20mm. In conclusion, In order to obtain high quality of perfusion Images In human brain It Is Important to use optimum parameters. Before routinely using In clinical studios, we recommend to make optimizations of sequence parameters.

  • PDF

Intravenous contrast media application using cone-beam computed tomography in a rabbit model

  • Kim, Min-Sung;Kim, Bok-Yeol;Choi, Hwa-Young;Choi, Yoon-Joo;Oh, Song-Hee;Kang, Ju-Hee;Lee, Sae-Rom;Kang, Ju-Han;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • Purpose: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. Materials and Methods: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. Results: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Conclusion: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

Sequential 1H MR Spectroscopy(MRS) Studies of Kaolin-Induced Hydrocephalic Cat Brain (Kaolin 유발 고양이 수두증 모델에서 양자 자기공명 분광상의 경시적 변화)

  • Kim, Myung Jin;Hwang, Sung Kyoo;Hwang, Jeong Hyun;Chang, Yongmin;Kim, Yong Sun;Kim, Seung Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1421-1428
    • /
    • 2000
  • Objectives : The aim of this study is to evaluate the sequential metabolic changes in experimental hydrocephalus and the clinical applicability to the diagnosis and prognosis of hydrocephalus using proton MR spectroscopy. Methods : Hydrocephalus was experimentally induced in 30 cats(2-3kg body weight) by injecting 1ml of sterile kaolin suspension(250mg/ml) into the cisterna magna. Proton MRS was performed with a 1.5 T MRI/MRS unit (Vision Plus, Siemens) at pre-treatment and at 1, 3, 7, 14, 21, and 28 days after the kaolin injection. PRESS(TR/TE=1500/270msec) technique was employed. The major metabolites which include N-acetyl aspartate (NAA), creatine(Cr), choline(Cho), and lactate(Lac) were quantitatively analyzed and the relative concentrations ratios were evaluated. Multislice $T_2$-weighted images were also obtained using fast spin echo sequence(TR/TE= 2500/96msec) to monitor the morphologic changes along with progression of hydrocephalus. Results : Hydrocephalus was successfully induced in all 30 cats. Twenty five cats died within 3 days and one at the end of the second week. In all animals, the NAA/Cr ratios initially decreased during the acute stage. In 4 surviving cats, the NAA/Cr ratios initially decreased during the acute stage(<14 days) and then gradually increased to the prekaolin level as follows : pre-kaolin($1.49{\pm}0.04$), day 1($1.11{\pm}0.07$), day 7($1.17{\pm}0.04$), day 14($1.40{\pm}0.03$), day 21 ($1.46{\pm}0.06$), day 28($1.43{\pm}0.03$). These levels were relatively well correlated with the symptomatologic improvement. Lactate peak, which reflects the evidence of ischemia, did not appear throughout the entire period except in one case which expired at the end of the second week. Conclusions : The NAA/Cr ratio of the sequential proton MRS in kaolin-induced hydrocephalic cats reflects a metabolic aspect of the hydrocephalus at each stage. A decreased NAA level at the early stage is from both neuronal and axonal damage which may provide diagnostic information in the acute stage of hydrocephalus. In addition, the initial fall of NAA/Cr ratio and recovery in the late stage, when no lactate peak emerges, may suggest that the main insult of the parenchyma is not to the neuron itself but to the axon, which may be related to a good prognosis. However, emergence of the lactate peak and unrecoverable NAA/Cr at the end of the acute phase may be a poor prognostic factor. In the chronic stage, recovery of NAA/Cr ratio may provide a diagnostic clue for the differentiation between hydrocephalus and cortical atrophy.

  • PDF