• 제목/요약/키워드: Multiple winding

검색결과 42건 처리시간 0.03초

다중일차권선 비접촉변압기를 이용한 비접촉 전원시스템의 공진주파수 추적에 관한 연구 (Study on resonant frequency tracking for contactless power system using multiple primary winding contactless transformer)

  • 김윤호;노성찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권3호
    • /
    • pp.182-188
    • /
    • 2006
  • Contactless power system is base on power transmission by magnetic force. The transformer loss is large because it separated with the gap. Also the system has unstable factor, since the parameters in the secondary can vary with the system movement. This paper proposes light train power transmission system using contactless transformer with multiple primary winding. To increase the system efficiency and to obtain the stable power transmission to the dynamic load, a resonant inverter is adopted. The proposed system was verified by the simulation using Spice and Maxwell. The designed contactless power transmission system is implemented for 5[kW] class and experimental results are discussed.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

Magnetic Field Calculation and Multi-objective Optimization of Axial Flux Permanent Magnet Generator with Coreless Stator Windings

  • Zhu, Jun;Li, Shaolong;Song, Dandan;Han, Qiaoli;Li, guanghua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1586-1595
    • /
    • 2018
  • For the problem that the complexity of 3-D modeling and multi parameter optimization, as well as the uncertainty of the winding factor of axial flux permanent magnet generator with coreless windings. The complex 3-D model was simplified into 2-D analytic model, and an analytical formula for the winding factor that adapting different coreless stator winding is proposed in this paper. The analytical solution for air-gap magnetic fields, no-load back EMF, electromagnetic torque, and efficiency are calculated by using this method. The multiple objective and multivariable optimization of the maximum fundamental and the minimum harmonic content of back EMF are performed by using response surface methodology. The proposed optimum design method was applied to make a generator. The generator was tested and the calculated results are compared with the proposed method, which show good agreements.

Application of Multiple Parks Vector Approach for Detection of Multiple Faults in Induction Motors

  • Vilhekar, Tushar G.;Ballal, Makarand S.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.972-982
    • /
    • 2017
  • The Park's vector of stator current is a popular technique for the detection of induction motor faults. While the detection of the faulty condition using the Park's vector technique is easy, the classification of different types of faults is intricate. This problem is overcome by the Multiple Park's Vector (MPV) approach proposed in this paper. In this technique, the characteristic fault frequency component (CFFC) of stator winding faults, rotor winding faults, unbalanced voltage and bearing faults are extracted from three phase stator currents. Due to constructional asymmetry, under the healthy condition these characteristic fault frequency components are unbalanced. In order to balanced them, a correction factor is added to the characteristic fault frequency components of three phase stator currents. Therefore, the Park's vector pattern under the healthy condition is circular in shape. This pattern is considered as a reference pattern under the healthy condition. According to the fault condition, the amplitude and phase of characteristic faults frequency components changes. Thus, the pattern of the Park's vector changes. By monitoring the variation in multiple Park's vector patterns, the type of fault and its severity level is identified. In the proposed technique, the diagnosis of faults is immune to the effects of unbalanced voltage and multiple faults. This technique is verified on a 7.5 hp three phase wound rotor induction motor (WRIM). The experimental analysis is verified by simulation results.

새로운 시분할 다중 제어 기법에 기반한 다중 출력 충전기 (Multiple Output Charger based on the Novel Time Division Multiple Control Technique)

  • 트란반롱;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.13-14
    • /
    • 2013
  • Multiple output converters (MOCs) are widely used for applications which require various kinds of the output voltages due to its advantages in cost, volume, and efficiency. However, most of the MOCs developed so far can regulate only one output tightly and require as many secondary windings in the transformer as the number of the outputs. In this paper, a novel Time Division Multiple Control (TDMC) method to regulate all the outputs in high precision is proposed and applied to the double ended forward converter for the multiple battery charger. Additional benefit of the proposed topology is to require only one secondary winding in the transformer for all the outputs. The proposed converter can charge two different kinds of batteries or same kind of batteries in different state of charges (SOCs) by CC/CV mode independently with the even degree of tight regulation, thereby satisfying the ripple requirements for each battery.

  • PDF

LLC 공진 컨버터에 적합한 자동화 권선 LLC 공진 변압기 설계에 관한 연구 (A Study on LLC Resonant Transformer Design with the Winding Method of Automatic Type suitable for LLC Resonant Converter)

  • 배준형;김종해
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.1108-1111
    • /
    • 2019
  • 본 논문은 LLC 공진 컨버터에 적합한 자동화 권선 변압기 설계에 대한 포괄적인 방법에 대해서 나타낸다. 기존의 LLC 공진 변압기는 하나의 보빈에 모든 권선이 감겨져 있기 때문에 자동화 권선 구현이 어렵다는 문제점이 있다. 따라서 본 논문에서는 절연 테이프와 배리어 테이프가 없이 다중 보빈으로 자동 권선이 가능한 LLC 공진 변압기를 제안하였으며 제안한 LLC 공진 변압기의 설계 절차에 대해서도 나타내었다. Maxwell 3D 시뮬레이션 툴을 이용하여 제안한 LLC 공진 변압기의 해석 및 모델링을 상세하게 기술되었으며 또한 3D 모델링에 의해 제작된 제안한 LLC 공진 변압기를 이용하여 프로타입 150W LLC 공진 컨버터를 실험을 통해 확인하였다.

KSR-III 복합재 가압탱크의 설계 및 제작

  • 공철원;윤종훈;장영순;이영무
    • 항공우주기술
    • /
    • 제2권2호
    • /
    • pp.124-132
    • /
    • 2003
  • 본 논문에서는 "KSR-III 복합재 가압탱크“에 대한 구조 설계/제작 과정을 기술하였다. 복합재 가압탱크는 라이너 위에 복합재가 덮어 씌워진 형태이다. 하중을 부담하지 않는 라이너는 AI 6061-0로 만들어 졌으며, 라이너는 헬륨가스 기밀만을 담당하였다. 복합재 탱크는 라이너 위에 T700/Epoxy로 와인딩 하였다. 알루미늄 라이너가 얇았기 때문에 다단계 경화 공정이 필라멘트 와인딩 기법에 적용되었다. 다단계 경화 공정은 라이너의 실린더가 원형 형상을 잃지 않게 하였다. 보스부의 체결력은 보스링에 의하여 카본섬유로 분산되었다. 또한 보스링은 보스부의 국부적 변형을 막았다.

  • PDF

전동차 출입문 구동을 위한 SRM용 C-dump 컨버터 Topology 특성 비교 (Characteristic Analysis of C-dump Converter Topology for SRM of Electric Multiple Unit Door Driving)

  • 윤용호
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1597-1604
    • /
    • 2016
  • The speed at which the SRM (Switched Reluctance Motor) makes a transition from chopping control to single pulse operation. (i.e., low speed to high speed operation). It is unsatisfied with performance at all operational regimes. In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on energy efficient C-dump converter topology and the proposed resonant C-dump converter topology. Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

영상신호처리 기법을 이용한 고압전동기 고정자권선 절연결함신호 분류 (Classification of Insulation Fault Signals for High Voltage Motors Stator Winding using Image Signal Process Technique)

  • 박재준;김희동
    • 한국전기전자재료학회논문지
    • /
    • 제20권1호
    • /
    • pp.65-73
    • /
    • 2007
  • Pattern classification of single and multiple discharge sources was applied using a wavelet image signal method in which a feature extraction was applied using a hidden sub-image. A feature extracting method that used vertical and horizontal images using an MSD method was applied to an averaging process for the scale of pulses for the phase. A feature extracting process for the preprocessing of the input of a neural network was performed using an inverse transformation of the horizontal, vertical, and diagonal sub-images. A back propagation algorithm in a neural network was used to classify defective signals. An algorithm for wavelet image processing was developed. In addition, the defective signal was classified using the extracted value that was quantified for the input of a neural network.

오픈 와인딩 머신을 이용한 계통 연계형 분산 발전 시스템의 제어 (Control of an Open Winding Machine in a Grid-Connected Distributed Generation System)

  • 곽무신;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.83-86
    • /
    • 2006
  • A grid-connected distributed generation system which consists of engine generator, dc link with multiple energy sources and inverter is proposed. All six of the stator leads of the generator, which is a surface mount permanent magnet machine, are brought out to the terminal of the generator. Three leads are connected to the inverter and the others are connected to the utility grid. In this proposed system the power from the engine-generator and the power from dc link can be controlled simultaneously by only one three-phase power converter. A control algorithm for the system is developed and verified by experiment results.

  • PDF