• 제목/요약/키워드: Multiple implant

검색결과 198건 처리시간 0.019초

The cumulative survival rate of sandblasted, large-grit, acid-etched dental implants: a retrospective analysis

  • Haeji Yum;Hee-seung Han;Kitae Kim;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • 제54권2호
    • /
    • pp.122-135
    • /
    • 2024
  • Purpose: This retrospective study aimed to assess the long-term cumulative survival rate of titanium, sandblasted, large-grit, acid-etched implants over a 10-year follow-up period and investigate the factors affecting the survival rate and change in marginal bone loss (MBL). Methods: The study included 400 patients who underwent dental implant placement at the Department of Periodontology of Seoul National University Dental Hospital (SNUDH) between 2005 and 2015. Panoramic radiographic images and dental records of patients were collected and examined using Kaplan-Meier analysis, Cox proportional hazards regression analysis, and multiple regression analysis to determine the survival rates and identify any factors related to implant failure and MBL. Results: A total of 782 implants were placed with a follow-up period ranging from 0 to 16 years (mean: 8.21±3.75 years). Overall, 25 implants were lost, resulting in a cumulative survival rate of 96.8%. Comparisons of the research variables regarding cumulative survival rate mostly yielded insignificant results. The mean mesial and distal MBLs were 1.85±2.31 mm and 1.59±2.03 mm, respectively. Factors influencing these values included age, diabetes mellitus (DM), jaw location, implant diameter, bone augmentation surgery, and prosthetic unit. Conclusions: This study found that the implant survival rates at SNUDH fell within the acceptable published criteria. The patients' sex, age, DM status, implant location, implant design, implant size, surgical type, bone augmentation, and prosthetic unit had no discernible influence on long-term implant survival. Sandblasted, large-grit, acid-etched implants might offer advantages in terms of implant longevity and consistent clinical outcomes.

임프란트 표면 처리에 따른 공명주파수 변화에 대한 연구 (COMPARISON OF RESONANCE FREQUENCY ANALYSIS BETWEEN VARIOUS SURFACE PROPERTIES)

  • 배상범;이성현;송승일
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권2호
    • /
    • pp.107-111
    • /
    • 2010
  • Purpose: The aim of this study is to compare the stability between Mg-incorporated implant, TiUnite and Machined implant. Materials and Methods: Premolars of 3 Mini pigs (24 months) were extracted. After 2 months later, total 27 fixtures of implants (9 of each design : Machined/ TiUnite/ Mg-incorporated) were inserted into the mandible of 3 mini-pig. Implant stability was estimated by RFA in installation to 2, 4 & 6 weeks. Statistical analysis of RFA values was performed with time and between groups using repeated measure ANOVA and turkey's multiple comparison test. Results: In analyzing the mean value for the observation periods, three types of implants yielded a slight decrease in RFA mean value after 2 week, followed by increase at 4-6 weeks. Mg incorporated oxidized implants demonstrated significantly higher RFA mean values at 6 weeks comparing other groups. The difference of RFA value with time and between groups was statistically significant. Conclusion: We concluded that Mg implants may reduce failure rates of clinical implants In the early period of bone healing and Mg implants may shorten the bone healing time from surgery to functional loading.

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

  • Katic, Visnja;Kamenar, Ervin;Blazevic, David;Spalj, Stjepan
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.177-183
    • /
    • 2014
  • Objective: To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. Methods: Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-implants (Ortho Easy$^{(R)}$, Aarhus, and Dual Top$^{TM}$) with diameters ranging from 1.4 to 2.0 mm and lengths of 6 and 8 mm were measured. Maximum insertion torque was recorded during manual insertion of mini-implants into bone samples. Cortical bone thickness was measured. Retrieved data were analyzed in a multiple regression model. Results: Significant predictors for higher maximum insertion torque included larger outer diameter of implant, higher lead angle of thread, and thicker cortical bone, and their unique contribution to maximum insertion torque was 12.3%, 10.7%, and 24.7%, respectively. Conclusions: The maximum insertion torque values are best controlled by choosing an implant diameter and lead angle according to the assessed thickness of cortical bone.

Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year

  • Kwon, Min-Jung;Yeo, In-Sung;Kim, Young-Kyun;Yi, Yang-Jin;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.54-57
    • /
    • 2010
  • PURPOSE. The aim of this study was to evaluate the periodontal and prosthodontic complications of multiple freestanding implants in the posterior jaws for up to 1 year of function. MATERIALS AND METHODS. Eight patients received 20 implants posterior to canines. Two or more implants were consecutively inserted to each patient. Single crowns were delivered onto the implants. Marginal bone loss, implant mobility, probing depth, and screw loosening were examined to evaluate the clinical success of such restorations for maximum 1 year of functional loading. RESULTS. All the implants performed well during the observation period. Neither periodontal nor prosthodontic complications were found except a slight porcelain chipping. While the marginal bone level was on average 0.09 mm lower around the implant after 6 months of loading, it was 0.15 mm higher after 1 year. CONCLUSION. Within the limits of this investigation, separate single-tooth implant restorations to replace consecutive missing teeth may clinically function well in the posterior jaw.

Cumulative survival rate and associated risk factors of Implantium implants: A 10-year retrospective clinical study

  • Park, Jin-Hong;Kim, Young-Soo;Ryu, Jae-Jun;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.195-199
    • /
    • 2017
  • PURPOSE. The objective of this study was to determine the cumulative survival rate (CSR) and associated risk factors of Implantium implants by retrospective clinical study. MATERIALS AND METHODS. Patients who received Implantium implants (Dentium Co., Seoul, Korea) at Korea University Guro Hospital from 2004 to 2011 were included. The period between the first surgery and the last hospital visit until December 2015 was set as the observation period for this study. Clinical and radiographic data were collected from patient records, including all complications observed during the follow-up period. Kaplan-Meier analysis was performed to examine CSR. Multiple Cox proportional hazard model was employed to assess the associations between potential risk factors and CSR. RESULTS. A total of 370 implants were placed in 121 patients (mean age, 56.1 years; range, 19 to 75 years). Of the 370 implants, 13 failed, including 7 implants that were lost before loading. The 10-year cumulative survival rate of implants was 94.8%. The multiple Cox proportional hazard model revealed that significant risk factor of implant failure were smoking and maxillary implant (P<.05). CONCLUSION. The 10-year CSR of Implantium implants was 94.8%. Risk factors of implant failure were smoking and maxillary implant.

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

치과용 임플란트 보철물적용환자의 만족요인 (A Study on Satisfaction Factors with Dental Implant Patients)

  • 이성욱;김지환
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.67-81
    • /
    • 2006
  • This research has been attempt to examine closely factors that high cost and value to overall satisfaction state for dental implant prosthesis, re-utilization intention, inducement intention of the general hospital dental service user and provide basis data necessary to establish competitive general hospital dentistry management strategy. Collected data using own recording way questionnaire from April 17, 2004 to May 15, 2004 choosing 142 people that agree on this research and question of 361 people that dental implant prosthetic treatment finished from March 1, 1999 to March 1, 2004 for this. Major analyzation consequences are as follows : First, general satisfaction, re-utilization intention, inducement intention for implant prosthesis that highly correlation variables are kindness, explanation, medical treatment level and appreciation of the aesthetic. Second, correlation is high relatively between re-utilization intention, inducement intention in the 3 variables such as general satisfaction re-utilization intention, inducement intention. Third, the result of multiple regression analysis showed that most significant effective factors are satisfaction with explanation of dental implant prosthesis between the 3 dependant variables such as general satisfaction, re-utilization intention, inducement intention. In looking into these consequence, how to improve that raise satisfaction about dental implant prosthetic treatment and to establish patient focused care service system for dental implant prosthesis, it is consider that explain enough about implant prosthesis and raise quality of medical examination and treatment level, including satisfied with fabrication of good esthetic dental implant prosthesis.

  • PDF

다양한 임플란트 엔진 시스템에 대한 사용자 만족도 비교 (The comparative study of user satisfaction on various implant engine system)

  • 이두형;이규복
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.9-15
    • /
    • 2014
  • 목적: 임플란트 엔진 시스템은 임플란트 시술 과정에서 사용하며 핸드피스, 구동모터, 본체, 그리고 풋스위치로 구성되어 있다. 본 연구의 목적은 임플란트 엔진 시스템의 편의성, 디자인 그리고 전체 만족도를 평가하고, 임플란트 식립 경험와 평가와의 관련성을 조사하고자 하였다. 연구 재료 및 방법: 총 30명의 치과의사를 대상으로 구조화된 설문지를 통해 3개 제조사의 시스템(NSK 의 SurgicXT와 X-SG20L, KaVo의 INTRAsurg300와 CL3-09, Saeshin의 XIP10와 CRB26LX)의 편의성, 디자인, 만족도를 비교 연구의 방식으로 조사하였다. 통계분석은 일원배치 분산분석과 중회귀분석을 이용하였다. 결과: 전체 만족도는 각기 다르게 나타났고(P < 0.05), 전체 만족도에는 편의성 평가가 디자인 평가보다 더 큰 영향을 미쳤다. 임플란트 수술 경험의 정도와 일부 영역의 평가와는 관련이 있었다. 결론: 임플란트 엔진 시스템의 횡단적 단면 평가 시에 디자인이 전체 만족도에 영향을 미치고, 임플란트 식립 횟수는 평가 시 영향력 있는 인자가 될 수 있음을 관찰할 수 있었다.

임플란트의 생존에 영향을 미치는 요인에 대한 장기간의 후향적 연구 (Factors affecting the survival of implants: a long-term retrospective study)

  • 송수산나;이재관;엄흥식;장범석
    • 구강회복응용과학지
    • /
    • 제31권1호
    • /
    • pp.10-19
    • /
    • 2015
  • 목적: 이 연구는 임플란트의 장기간 생존율을 후향적으로 평가하고, 이에 영향을 미치는 요인을 분석하는 것이었다. 연구 재료 및 방법: 1998년 1월부터 2012년 12월까지 강릉원주대학교 치과병원 치주과에서 식립된 임플란트 중 2013년 6월까지 주기적으로 검사가 이루어지고 있는 2265개의 임플란트를 대상으로 하였다. 환자의 진료기록부와 방사선 사진을 통해 성별, 연령, 흡연 여부, 임플란트 직경, 임플란트 길이, 임플란트 표면, 임플란트 식립 부위, 동반된 술식, 합병증 유무에 대한 자료를 조사하였다. 결과: 임플란트 식립 후 보철 전 생존율은 98.9%, 보철 후 5년간 누적생존율은 97.2%, 15년간 누적생존율은 95.2% 이었다. 단순로지스틱회귀분석 시 성별, 흡연 여부, 임플란트 식립 부위 및 합병증 유무가 임플란트 실패와 유의하게 관련되었다. 이 변수들로 다중로지스틱회귀분석을 시행한 결과, 흡연 여부와 합병증 유무만이 임플란트 실패와 유의하게 관련된 것으로 나타났다. 결론: 2265개의 임플란트를 대상으로 15년간의 누적생존율을 조사한 결과 95.2% 이었다. 흡연가이거나, 임플란트 합병증이 존재할 경우 임플란트의 실패율이 유의하게 증가되었다.

과도한 치아 마모와 다수의 치아 상실을 보이는 환자에서 computer tomography guided implant surgery와 수직고경 회복을 동반한 완전 구강 회복 증례 (Full-mouth rehabilitation with vertical dimension increase and computer tomography guided implant surgery in patient with excessive worn dentition and multiple loss of tooth)

  • 이경섭;임영준;권호범;김명주
    • 대한치과보철학회지
    • /
    • 제57권1호
    • /
    • pp.66-74
    • /
    • 2019
  • 과도한 마모는 치료받지 않을 시 여러 문제점들을 야기시킬 수 있기 때문에, 정확한 분석 및 진단을 바탕으로 예지성 있는 치료계획을 수립하도록 노력해야 하고, 수직고경에 대한 평가 및 그에 따른 단계적인 치료를 통해 안정된 악간 관계를 회복시켜 주어야 한다. 또한 임플란트 치료의 장기적인 성공을 위해서는 이상적인 위치와 각도로 임플란트를 식립하는 것이 중요하며, 다수의 임플란트 치료에서는 그 중요성이 더욱 증가한다. 따라서 철저한 계획 및 진단에 따른 정확한 수술과 보철 과정이 중요하다. 본 증례에서는 다수의 치아 상실 및 전반적인 치아 마모로 인해 수직고경이 상실되어 있는 68세의 남자 환자에게 치료 전 단계에서부터 다양하고 체계적인 분석을 통해 수직고경을 회복하는 치료 계획을 세웠다. 콘빔컴퓨터단층촬영 데이터를 활용하여 새로 설정한 수직고경에 맞춰 가이드 수술을 시행하였고, 임플란트를 포함한 전악 고정성 보철 수복을 통해 기능 및 심미적으로 환자와 술자 모두 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.