• Title/Summary/Keyword: Multiple failure

Search Result 937, Processing Time 0.029 seconds

Reliability Analysis of Multiple Failure Modes of Rubble-Mound Breakwaters (경사제의 다중 파괴모드에 대한 신뢰성 해석)

  • Lee, Cheol-Eung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • A reliability analysis has been performed to investigate the systematic stability of multi-failure modes of rubble-mound breakwaters. The reliability functions of four different failure modes are established straightforwardly. AFDA(Approximate Full Distribution Approcah) reliability models for each failure modes are directly developed and satisfactorily calibrated through the comparison with CIAD's results. In the reliability analysis of single failure mode, the probabilities of failure are calculated and the influence coefficients of random variables in the failure modes are properly evaluated. Meanwhile, three different models such as uni-modal bounds, bimodal bounds, and PNET are applied to evaluate the probabilities of failure of multi-failure modes for rubble-mound breakwaters. It may be found that uni-modal bounds tend to overestimate the probability of failure of multi-failure modes. Therefore, for the systematic reliability analysis of multi-failure modes, it is recommended to use bi-modal bounds or PNET which consider the correlation between the failure modes for rubble-mound breakwaters. By introducing the reliability analysis of multi-failure modes, it could be possible to find out the additional probabilities of failure occurred by the multi-failure modes of a multi-component system such as rubble-mound breakwaters.

Design for Extension Supply Contactor control of train with multiple Auxiliary Power Generator (다중 전원장치를 갖는 차량의 연장급전 제어방안)

  • Shin, Kwang-Kyun;Han, Jeong-Soo;Choi, Jong-Muk
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1222-1227
    • /
    • 2006
  • These days customers require various things such as multiple train, variable trainset, multiple Auxiliary Power Generator(APG) and so on. Among these, the train with multiple APG is installed with APG in each car. Thus, we control and monitor train installed with multiple APG through the TCMS(Train Control & Monitoring System). The TCMS supervise APG failure status and transmit control data in case of a APG failure or more, so energize or de-energize ESK and LRR. Therefore, we can easily control ESK and LRR which gets hard to control because of multiple APG.

  • PDF

Estimating the Failure Rate of a Large Scaled Software in Multiple Input Domain Testing (다중입력영역시험에서의 대형 소프트웨어 고장률 추정 연구)

  • 문숙경
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.186-194
    • /
    • 2002
  • In this paper we introduce formulae for estimating the failure rate of a large scaled software by using the Bayesian rule when a black-box random testing which selects an element(test case) at random with equally likely probability, is performed. A program or software can be treated as a mathematical function with a well-defined (input)domain and range. For a large scaled software, their input domains can be partitioned into multiple subdomains and exhaustive testing is not generally practical. Testing is proceeding with selecting a subdomain, and then picking a test case from within the selected subdomain. Whether or not the proportion of selecting one of the subdomains is assumed probability, we developed the formulae either case by using Bayesian rule with gamma distribution as a prior distribution.

FMEA Measures for Service Failure Management (서비스 실패 관리를 위한 FMEA 이용 방안)

  • Kim, Hyun Jung;An, Qin Rui;Kim, Soo Wook
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.1
    • /
    • pp.43-61
    • /
    • 2014
  • Purpose: This study identifies preventive measures for VOC management by analyzing the causes and effects of factors that contribute to high risk service failure using FMEA on KORAIL VOC data. Methods: Two research methods were used. First, a Risk Priority Number (RPN) was assigned to each KORAIL VOC based on Failure Mode and Effect Analysis (FMEA). Second, multiple regression analysis was run with RPN factors that include severity, occurrence, and detection as the independent variables and customer dissatisfaction as the dependent variable. Results: Multiple regression analysis showed that RPN factors including severity, occurrence, and detection had significantly positive relationship with customer dissatisfaction. Based on these results, an FMEA was performed on VOC categories with high RPN for railroad stations including platform, ticketing, ticket verification, parking, and escalator, and VOC categories with high RPN for trains including entrance doors, cafes, air quality, announcement, and ticket verification. Conclusion: This study has practical implications to service failure management. A priority order using FMEA was established for the list of customer dissatisfactions that should be addressed to actively manage service failure, and strategies for tackling this priority list are offered.

Development of Multiple Fault Diagnosis Methods for Intelligence Maintenance System (지적보전시스템의 실시간 다중고장진단 기법 개발)

  • Bae, Yong-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2004
  • Modern production systems are very complex by request of automation, and failure modes that occur in thisautomatic system are very various and complex. The efficient fault diagnosis for these complex systems is essential for productivity loss prevention and cost saving. Traditional fault diagnostic system which perforns sequential fault diagnosis can cause catastrophic failure during diagnosis when fault propagation is very fast. This paper describes the Real-time Intelligent Multiple Fault Diagnosis System (RIMFDS). RIMFDS assesses current machine condition by using sensor signals. This system deals with multiple fault diagnosis, comprising of two main parts. One is a personal computer for remote signal generation and transmission and the other is a host system for multiple fault diagnosis. The signal generator generates various faulty signals and image information and sends them to the host. The host has various modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault diagnosis and graphic representation of the results. RIMFDS diagnoses multiple faults with fast fault propagation and complex physical phenomenon. The new system based on multiprocessing diagnoses by using Hierarchical Artificial Neural Network (HANN).

Clinical Evaluation of Multiple Valve Replacement (심장다판치환술의 임상적 고찰)

  • 오상기
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.160-166
    • /
    • 2000
  • Background: The purpose of this study is to evaluate and analyze the surgical results in patients undergoing operations for multiple for multiple valvular heart diseases. Material and method: From April 1982 to June 1997 multiple valve replacement was performed in 150 patients mitral and aortic valve replacement were done in 135 patients mitral and tricuspid valve replacements in 10 patients triple replacements in 4 patients and aortic and tricuspid valve replacement in 1 patient. Of the valves implanted 157 were St. Jude 104 Duromedics 20 Carpenter-Edwards 6 Bjork-Shiley 6 Ionescu-Shiley and 2 Medtronics. Result: The hospital mortality rate was 10.7% (16/150) and the late mortality rate was 7.2% (8/134) The mortality rate was high in early operative period but decreased with time. The causes of death were low cardiac output in 9 sudden death in 3 congestive heart failure in 3 bleeding in 2 cerebral thrombosis in 1 leukemia in 1 multiorgan failure in 1 and so on . The actuarial survival rate excluding operative death was 83.1% at 15 years. Conclusion: With a follow-up now extending to 15 years the multiple valve replacement continues to be reliable procedure with relatively low mortality and morbidity.

  • PDF

Protection and Restoration Scheme Based on Eulerian Tours in Survivable Optical Mesh Networks (서바이버블 광 메쉬망에서 다중 장애에 강인한 오일러 투어 기반 보호 복구 방식)

  • Shon, Min-Han;Lee, Tae-Jin;Chung, Min-Young;Choo, Hyun-Seung
    • The KIPS Transactions:PartC
    • /
    • v.11C no.5
    • /
    • pp.653-658
    • /
    • 2004
  • Failures in optical networks that have huge transmission capability provoke service discontinuitH and thus large economical damage. Even though many algorithms are proposed for protection and restoration on a single failure, there are few algorithms for multiple failures. Eulerian tour is known to be effective to protect and restore a single failure in the literature. This paper proposes an algorithm that can perform efficient protection and restoration for multiple failures based on combined Eulerian tours. The proposed one is very effective on protection and restoration in general cases with two failures, and the comprehensive computer simulation shows that the restoration rate increases up to about 90%.

AE Characteristics on Microscopic Failure Behavior of Carbon/Epoxy Comosite Prepared by Cocure and Precure Process (Cocure/Precure 경화공정에 의해 제조된 Carbon/Epoxy 복합재료의 미시적 파손거동에 대한 AE 특성)

  • Lee, Jin-Gyeong;Lee, Jun-Hyeon;Lee, Min-Rae;Choe, Heung-Seop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2520-2528
    • /
    • 2000
  • Mechanical and physical properties of composite materials make a great difference due to their cure process condition. In order to clarify the effect of cure process condition on the microscopic damage behavior and failure mechanism of Carbon/Epoxy composites, three point bend test has been performed. For this purpose, two kinds of specimens with single adhesive and multiple adhesive layers were prepared. For single adhesive layer, four different types of specimen were used, that is, non-sanding, sanding, cocured, laminated specimens. Three different types of specimen were also used for the multiple adhesive layer, non-sanding, sanding, cocured specimens. Acoustic emission technique has also been employed to monitor the damage progresses associated with each micro-failure mechanism. The characteristics of AE parameters associated with micro-failure mechanism of each specimen were discussed.

Remarks on Education Method to Turn Failure Experience to Instructions for Engineering Design

  • Arimitsu, Yutaka;Yagi, Hidetsugu
    • Journal of Engineering Education Research
    • /
    • v.13 no.2
    • /
    • pp.74-77
    • /
    • 2010
  • This article proposes to examine how the study of failure differs from other technical subjects, and how to turn failure experiences to one's advantage. The authors surveyed the properties of failures in PBL (Project Based Learning) and also examined students' interest and understanding of failure, after introducing failure examples. To investigate how students communicate failure experiences to third parties, reports of the failure experience in PBL were evaluated. From above mentioned surveys, we get the following results. The typical causes of failure in educational institutions are lack of skill in manufacturing and inadequate planning, which conversely are minor causes of failure in the industry. A knowledge database on failure, employed commonly in industry, is not effective in PBL, because projects in educational institutes are usually changed every year. Case studies in failure can be approached from many points of view including causes, processes, effects and safety measures. While teachers should emphasize the notable points in the failure examples in introducing examples of specific topics in machine design, teachers should explain the multiple aspects in the failure examples to educate students about the complexity of actual accidents.

  • PDF

Verification of SPACE Code with MSGTR-PAFS Accident Experiment (증기발생기 전열관 다중파단-피동보조급수냉각계통 사고 실험 기반 안전해석코드 SPACE 검증)

  • Nam, Kyung Ho;Kim, Tae Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.84-91
    • /
    • 2020
  • The Korean nuclear industry developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code and this code adpots two-phase flows, two-fluid, three-field models which are comprised of gas, continuous liquid and droplet fields and has a capability to simulate three-dimensional model. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for accident management plan of nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification work for separate and integral effect experiments is required. In this reason, the goal of this work is to verify calculation capability of SPACE code for multiple failure accident. For this purpose, it was selected the experiment which was conducted to simulate a Multiple Steam Generator Tube Rupture(MSGTR) accident with Passive Auxiliary Feedwater System(PAFS) operation by Korea Atomic Energy Research Institute (KAERI) and focused that the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The MSGR accident has a unique feature of the penetration of the barrier between the Reactor Coolant System (RCS) and the secondary system resulting from multiple failure of steam generator U-tubes. The PAFS is one of the advanced safety features with passive cooling system to replace a conventional active auxiliary feedwater system. This system is passively capable of condensing steam generated in steam generator and feeding the condensed water to the steam generator by gravity. As the results of overall system transient response using SPACE code showed similar trends with the experimental results such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it could be concluded that the SPACE code has sufficient capability to simulate a MSGTR accident.