• Title/Summary/Keyword: Multiple echo

Search Result 72, Processing Time 0.027 seconds

A Study on the Determination of Grain Size of Heat-treated Stainless Steel Using Digital Ultrasonic Signal Processing Techniques. (디지털 초음파 신호처리 기법을 이용한 열처리된 스테인레스 스틸의 그레인 크기 결정에 관한 연구)

  • 임내묵;이영석;김성환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.8
    • /
    • pp.84-93
    • /
    • 1999
  • Determination of grain size of heat-treated stainless steel based fm digital ultrasonic signal processing technique is presented. This techniques consist in evidence accumulation with multiple feature parameters, difference absolute mean value(DAMV), variance(VAR), mean frequency (MEANF), auto regressive model coefficient(ARC) and linear cepstrum coefficient(LCC). Feature parameters were extracted from ultrasonic echo signal of heat-treated metals. It was found that a few parameters might not be sufficient to exactly evaluate the grain size of heat-treated metals. The determination of grain size of heat-treated metals was carried out through the evidence accumulation procedure using the distances measured with reference parameters. A fuzzy mapping function is designed to transform the distances for the application of the evidence accumulation method. In the work presented, heat-treated stainless steel samples with various grain sizes are examined. The processed experimental results supports the feasibility of the grain size determination technique presented.

  • PDF

Resolution Enhancement of an Ultrasonic Sensor System via Multiple Steps of the Transmitter Voltage (다단 송출전압을 이용한 초음파센서 시스템의 분해능 개선)

  • Na, Seung-You;Park, Min-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.298-306
    • /
    • 1997
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensors are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of an object, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensors has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained without the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Implementation of Multi-Core Processor for Beamforming Algorithm of Mobile Ultrasound Image Signals (모바일 초음파 영상신호의 빔포밍 알고리즘을 위한 멀티코어 프로세서 구현)

  • Choi, Byong-Kook;Kim, Jong-Myon
    • The KIPS Transactions:PartA
    • /
    • v.18A no.2
    • /
    • pp.45-52
    • /
    • 2011
  • In the past, a patient went to the room where an ultrasound image diagnosis device was set, and then he or she was examined by a doctor. However, currently a doctor can go and examine the patient with a handheld ultrasound device who stays in a room. However, it was implemented with only fundamental functions, and can not meet the high performance required by the focusing algorithm of ultrasound beam which determines the quality of ultrasound image. In addition, low energy consumption was satisfied for the mobile ultrasound device. To satisfy these requirements, this paper proposes a high-performance and low-power single instruction, multiple data (SIMD) based multi-core processor that supports a representative beamforming algorithm out of several focusing methods of mobile ultrasound image signals. The proposed SIMD multi-core processor, which consists of 16 processing elements (PEs), satisfies the high-performance required by the beamforming algorithm by exploiting considerable data-level parallelism inherent in the echo image data of ultrasound. Experimental results showed that the proposed multi-core processor outperforms a commercial high-performance processor, TI DSP C6416, in terms of execution time (15.8 times better), energy efficiency (6.9 times better), and area efficiency (10 times better).

A Study on Sexual Function of Women with Coronary Artery Disease (관상동맥질환 여성의 성기능에 관한 연구)

  • Kim, Choon Shim;So, Hyang Sook
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.99-111
    • /
    • 2000
  • The purpose of this study was to identify risk factors related to sexual function of women with coronary artery disease, and to determine the predictors of sexual function. The study design, a descriptive correlational study, was done through structural questionnaire and interview. A total of 50 subjects from C University Hospital at Kwang-ju city who have undergone coronary angiography at department of cardiology were observed and interviewed from Feb. 22, 1999 to March. 23, 1999. The number of affected vessels, the level of total serum cholesterol, and the ejection fraction of 2-D echo cardiography were analyzed to evaluate the severity of coronary artery disease. And also type A behavior pattern, health behavior, Brief Index of Sexual Functioning for Women (BISF-W) were measured. The data obtained were analyzed using percentage, mean and standard deviation, t-test, ANOVA, Pearson's correlation coefficient, and stepwise multiple regression analysis via SPSS PC+. The results of this study were as follows: 1. The mean age of the subjects were 58.1 and 72.0% of those have been married over 30 years. Seventy two percentage were unemployed and monthly family income of 56.6% was less than 1,000,000 won (approximately $ 840). Eighty percent were in their postmenopausal state, and the frequency of sexual intercourse of 84.0% were two to three times per month. 2. The scores of type A behavior pattern were from 16 to 38(mean 24.94) and health behavior ranged from 21 to 43(mean 31.2). Abstinence from smoking, alcohol, and caffeine were best compliant factors and weight control and exercise were least abided ones. The result of 2D-ECHO EF showed that the half of the subjects were abnormal, and 24% had more than 240mg/dl of total serum cholesterol. The coronary angiography showed that 64% of the subjects had more than one affected vessels. 3. The predictors to explain the factor score of 'orgasm' were number of health examination, the pre- or post-menopausal state, protestant, number of coronary vessel affected, level of serum total cholesterol, and comorbid group of hypertension and diabetes, and it's total variance accounted for 52.4%. The predictors to explain the factor score of 'sexual activity' were comorbid group of hypertension and diabetes and type A behavior pattern, which accounted for 22.4% of total variance. The predictors to explain the factor score of 'sexual satisfaction' were type A behavior pattern, no religion, exercise, level of serum total cholesterol, and pre or post menopausal state, which accounted for 52.1%. The predictors to explain the factor score of 'sexual desire' were the period of marriage, type A behavior, employment or unemployment, and weight control, which accounted for 43.2%. The predictors to explain the factor score of 'external force of sexual functioning' were physical overload and exercise, which accounted for 41.1%. The predictors to explain the factor score of 'sexual activity' were family monthly income, catholics, and exercise, and which accounted for 35.4%. Above results lead us to some consensus that sexual function of women with coronary artery disease is related to various factors including vasogenic factors such as total serum cholesterol level, number of coronary vessel affected, an endocrinal factor such as menopausal state, and type A behavior pattern as a sociopshychological factor. And also health behaviors such as fitness care, overwork, weight control, and emotional tension are contributed to sexual function.

  • PDF

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.

A Study on Noise Characteristic of Multi-channel Seismic Data for the Hydrothermal Deposit Survey at Lau Basin, South Pacific (열수광상 탐사를 위한 남태평양 라우분지 다중채널 탄성파 자료의 잡음특성 연구)

  • Ok, Soo-Jong;Ha, Young-Soo;Lee, Jin-Woo;Shin, Sung-Ryul
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.235-235
    • /
    • 2011
  • Lau basin of south Pacific, as an active back arc basin, is promising area bearing seafloor massive hydrothermal deposit that is located in a subduction zone between the Pacific ocean plate and Indo-Australian continental plate. Korea Ocean Research and Development Institute tracked from 2004 to 2006 the hydrothermal activity to the extension of the northeast Lau Basin, targeting seamount. hydrothermal activity by tracking was found hydrothermal evidences. In this study, Marine seismic survey was carried out in the Lau basin seamount of the possibility of hydrothermal deposit. In particular, Marine magnetic survey and seismic survey was carried out at the same time in TA-12 seamount and noise characteristics were found in the seamount. the main process of data processing is Bandpass filter, FK filter, Deconvolution for noise attenuation such backscatter and multiple reflections. the migration is performed to compensate for reflection points followed by seamount of a slope. In this study, bedrock and upper strata could be identified and in the Future, the comparative method with Multi Beam Echo Sounder(MBES) are likely to derive the correct velocity model, the marine magnetic survey results should be considered.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

Operation of Ascending Aorta and/or Aortic Arch (상행대동맥 및 대동맥궁의 수술)

  • 구본원;허동명;전상훈;장봉현;이종태;김규태;이응배
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1212-1217
    • /
    • 1996
  • From Dec. 1993 to May 1995, 9 male and 5 female patients ranging in age from 25 to 65 years, were operated on for ascending aorta and/or aortic arch diseases. Six patients had acute aortic dissection, type A(ruptured in 4 cases); four had ruptured ascending aortic aneurysm; three had annuloaortic ectasia(ruptured in 1 cases); one had aortic arch aneurysm. The diagnostic procedures were echo cardiography and dynamic CT scan in all patients having acute dissection or rupture. The aortic angiography was performed in two cases. Indications for operations were rupture in five cases, acute aortic dissection in five cases, severe congestive heart failure in two cases, progressive aortic insufficiency in one case and impending rupture in one case. The emergent repair was performed in ten cases(71%). The surgical treatment consisted of 6 Cabrol operations, a Cabrol operation combined with arch replacement, a modified Bentall operation, 4 replacement of ascending aorta, a replacement of aortic arch, and a replacement of ascending aorta and aortic arch. Complications were a hypoxic encephalopathy, two atrial fibrillations, a sternal deheiscence, and a mediastinitis. Two early mortality(14%) were due to intractable bleeding and multiple organ failure, and one late mortality(7%) was due to ventricular arrhythmia. In eleven survivors, follow-up period was from 2 months to 12 months and the course was uneventful.

  • PDF

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF