• 제목/요약/키워드: Multiple echo

검색결과 72건 처리시간 0.023초

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

접착층에서 반사된 초음파 신호의 가시도 개선 (Visibility Enhancement of the Ultrasonic Signal Reflected from Adhesive Layers)

  • 신진섭;이정일
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권6호
    • /
    • pp.153-157
    • /
    • 2008
  • 최근 산업사회에서 널리 쓰이는 전자소자들은 다층구조로 제작되고 있는 실정이며 이러한 소자의 보이지 않는 층에 대한 해석은 비파괴 검사에서 중요한 일이다. 따라서 본 논문에서는 접착층이 존재하는 다층구조물에 초음파를 입사시켰을 때 반사되는 신호를 디지털 신호처리하여 가시도를 개선하였다. 이를 위하여 다층구조물에서 반사된 신호를 전력 켑스트럼 처리하여 각층에서 나타난 첫 번째 피크와 두 번째 피크를 구할 수 있었다. 실험을 위하여 일정한 두께를 갖는 에폭시층이 존재하는 다층구조물을 형성하였고 초음파 펄스-에코 방법에 의하여 얻어진 반사신호의 가시도를 개선하기 위해 전력 켑스트럼 처리하였다.

  • PDF

IEEE 802.11 무선랜에서 음성신호의 딜레이 바운드에 관한 분석 (Modeling and Analysis of Delay Bound for Voice Traffic in the IEEE 802.11 Wireless LAN)

  • 최원석;김영용
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2003년도 춘계학술발표논문집 (중)
    • /
    • pp.1485-1488
    • /
    • 2003
  • IEEE 802.11 무선 랜 환경에서 멀티미디어 트래픽이 효과적으로 전송퇴기 위해서는 정해진 딜레이 바운드내에서 전송이 완료되어야 한다 대표적인 멀티미디어 트래픽인 음성신호를 전송할 때의 단방향 딜레이 바운드는 echo canceller를 쓰지 않았을 경우 $25ms{\sim}30ms$ 이다. 딜레이 바운드를 지키지 못하고 전송된다면 시간에 민감한 음성신호의 특성 때문에 음성품질이 유지되지 않을 뿐만 아니라 채널의 혼잡을 유발하게 된다. 본 논문에서는 음성의 품질이 보장되는 기준을 95%이상의 패킷이 성공적으로 전달되는 경우로 제한하여 음성의 딜레이 바운드에 관한 분석을 시도하였다. 이를 위해 음성패킷이 drop될 확률을 수학적인 분석을 통해 유도하고 시뮬레이션을 통한 검증을 시도하였다. 시뮬레이션에서는 IEEE 802.11의 두 가지 기본적인 MAC(Multiple Access Control) 프로토콜인 DCF와 PCF를 사용해서 음성신호를 전송할 때 딜레이 바운드를 지키지 못하는 음성 패킷을 사전에 drop 시킴으로써 몇 개의 음성 노드가 손실율 5% 이내 (음성의 품질이 유지되는 한계)를 만족시키는지를 음성신호를 발생시키는 STA 수와 손실율의 관계를 통해 알아보았다.

  • PDF

Diffusion Weighted MR Imaging of Spinal Cord: Preliminary Report

  • 인연권;이승구;김상흠;김시연;김동익
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.166-166
    • /
    • 2001
  • 목적: 척수의 질환에 대한 확산강조영상 소견에 대하여 알아본다. 대상 및 방법: 임상적으로 진단된 척수질환 환자 8명을 (acute transverse myelitis (n=3), spinal dural AV fistula (n=2), multiple sclerosis (n=1), spinal cord tumor (n=2)) 대상으로 하였다. 영상은 Philips Intera 1.5 T system을 이용하였고, multishot spin echo EPI 펄스열 및 EKG gating을 이용하여 영상을 얻었다. 3R-R 간격으로 영상을 얻었으며 TE=72msec, FOV=25cm, 256 matrix, 5mm thickness, b value=400으로 영상매개변수를 정하였다. 척수 중심으로 3개의 절편을 얻었으며 T2 강조 영상과 겉보기확산계수 영상을 같이 구하였다.

  • PDF

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.

German Shepherd견의 혈관육종례 (Hemangiosarcoma in a German Shepherd Dog)

  • 윤정희;권오경;성재기
    • 한국임상수의학회지
    • /
    • 제13권1호
    • /
    • pp.87-92
    • /
    • 1996
  • A hemangiosarcoma in a 30 kg, 6-year-old German Shepherd dog showing signs of abdominal distension, anorexia and depression was diagnosed with clinicopathologic examination, abdominal radiographs and ultrasonographic assessmint. In abdominal radiographs, overall abdominal distension was seen. Stomach and some parts of small intestines were deviated caudo-ventrally by enlarged liver. The splenomegaly was also identified and descending colon was dislocated laterally by splenic mass. In ultrasonographic findings, abdominal fluid was identified. Hepatomegaly was seen and it was consisted of multiple, anechoic cysts. The spleen was enlarged and a large round mass with mixed echo pattern at the mid to tail portion of spleen was identified. Grossly, at necropsy, multi-sized cysts in which contained blood and fibrpus materials and some blood were seen in the cross section and it showed hard consistency. Also, lots of small red tumor nodules were dispersed on the serosal surface of the bladder, omentum, mesentery, diaphragm and peritoneum. In abdominal paracentesis, fluid having almost the same properties as circulating blood was identified. The hemoperitoneum was thought to be resulted from the bleeding into peritoneum owing to the rupture of cystic lesions located on the superficial liver area.

  • PDF

FM 신호 기반 PCL 시스템에서 간섭 신호 제거 알고리즘의 성능 분석 (Performance Analysis of Interference Cancellation Algorithms for an FM Based PCL System)

  • 박근호;김동규;김호재;박진오;이원진;고재헌;김형남
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.819-830
    • /
    • 2017
  • FM 신호 기반 PCL 시스템은 FM 송신탑에서 송신되는 신호를 이용하여 이동하는 표적의 위치를 추적하는 수동형 레이더 기술로서, 송신탑에서 수신기에 LOS (line-of-sight)로 입사되는 직접경로 신호와 표적으로부터 반사된 표적반사 신호의 상호 상관 함수를 유도하여 표적의 위치를 추적한다. 하지만, 직접경로 신호와 지형 및 지표면 등에서 반사되는 간섭 신호가 표적반사 신호 획득을 위한 감시 채널에 동시에 측정되며, 이에 따라 표적의 위치를 정확하게 탐지하지 못하는 문제가 발생한다. 간섭 신호 제거에는 적응 필터가 효과적인 것으로 알려져 있지만, 기존 연구에서는 상호 상관 함수나 적응 필터 입출력 신호의 전력 비율로부터 간섭 신호의 제거 성능을 유도하기 때문에, 정확한 성능 분석이 어려운 문제가 존재하였다. 본 논문에서는 필터 계수의 각 성분이 특정한 간섭 신호를 제거하기 위해 유도된다는 특징을 활용하여, 각 간섭 신호 제거 성능을 적응 필터 계수에 대한 함수로 정리한다. 제안한 성능 분석 방법을 기반으로 적응 필터 기법의 성능을 비교 및 분석하여, 제안한 방법이 간섭 신호 제거 성능 분석에 효과적으로 활용될 수 있음을 보인다.

크론병에서 자기공명영상 장운동기록의 단일호흡 단발 고속 스핀 에코기법: 딥러닝 기반 재구성의 영향 (Impact of Deep-Learning Based Reconstruction on Single-Breath-Hold, Single-Shot Fast Spin-Echo in MR Enterography for Crohn's Disease)

  • 박언주;이예다운;이준성
    • 대한영상의학회지
    • /
    • 제84권6호
    • /
    • pp.1309-1323
    • /
    • 2023
  • 목적 크론병 환자의 자기공명영상 장운동기록(MR enterography; 이하 MRE)에서 단발 고속 스핀 에코기법(single-shot fast spin-echo; 이하 SSFSE)을 이용한 단일호흡영상(singlebreath-hold; 이하 SBH)과 다호흡영상(multiple-breath-hold; 이하 MBH)을 딥러닝 기반 재구성(deep-learning based reconstruction; 이하 DLR)의 유무에 따라 네 개의 영상에서 품질을 비교했다. 대상과 방법 이 연구는 후향적 연구로서, 크론병으로 MRE를 시행한 61명의 환자가 포함되었다. SBH와 MBH SSFSE 영상에서 각각 DLR과 고식적 재구성(conventional reconstruction; 이하 CR)을 시행한 영상을 획득했다. 두 명의 영상의학과 전문의가 네 가지 영상을 분석하여 전반적인 영상의 품질, 인공물, 선명도와 움직임 관련 신호 손실에 대하여 각각 5점 척도를 이용해 점수를 부여했다. 회장과 말단 회장, 결장에서 염증을 시사하는 세 가지 소견을 평가했다. 각 영상에 대해서 공간적 불일치 여부를 확인했고, 네 가지 영상에서 각각 다른 두 위치에서 신호 대 잡음비(signal-to-noise ratio; 이하 SNR)를 계산했다. 결과 SBH SSFSE 영상에서 DLR을 적용한 경우 CR보다 영상의 품질, 인공물, 선명도가 통계학적으로 유의하게 개선되었다. 네 가지 영상 중 SBH-DLR 영상에서 SNR이 가장 높게 나타났다(p < 0.001). 염증 소견에 대한 판독자 간 일치율은 좋음에서 매우 좋음으로 나타났고(κ = 0.76-0.95) 시퀀스 간 일치율은 매우 좋음으로 측정되었다(κ = 0.92-0.94). 공간적 불일치는 SBH 영상보다 MBH 영상에서 통계학적으로 유의하게 빈도가 높았다(p < 0.001). 결론 SBH-DLR 영상은 MBH-CR 영상과 비교했을 때 동등한 영상 품질과 성능을 보여주었다. 또한, MBH 영상에 비해 절반 이하의 시간과 단일 호흡만으로 영상을 획득할 수 있으며 공간 불일치를 줄일 수 있는 대체제로 사용할 수 있다.

Recognition resolution enhancement of ultrasonic sensors via multiple steps of transmitter voltages

  • Na, Seung-You;Park, Min-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.409-412
    • /
    • 1996
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensing are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of objects, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensor has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained with neither the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

소나 위치 추정 성능 향상을 위한 LS기반 MRAL 후처리 기법 (MRAL Post Processing based on LS for Performance Improvement of Active Sonar Localization)

  • 장은정;한동석
    • 전자공학회논문지
    • /
    • 제49권9호
    • /
    • pp.172-180
    • /
    • 2012
  • 수중 표적의 탐지를 위한 다중상태 소나에서 수신 신호는 많은 잔향 및 클러터 성분을 포함한다. 이는 표적탐지에서 오경보율을 높이는 주된 원인이다. MRAL(multiple return association and localization) 알고리듬은 수신신호를 위치적인 유사성을 기준으로 몇 개의 그룹으로 분류하고, 그룹의 수신신호들을 한 개의 반사체로부터 온 것으로 봄으로써 오경보율을 낮춘다. 그러나 그룹화로 인하여 MRAL 알고리듬의 결과로 나타나는 표적 및 클러터 등의 위치는 실제위치와 차이를 보일 수 있다. 본 논문에서는 MRAL 알고리듬의 출력으로서 나타나는 표적 및 클러터의 위치와 실제 표적 및 클러터의 위치와 차이를 줄이기 위하여, 후처리 기법으로 최소제곱법을 이용한 LS기반 MRAL 후처리 기법 알고리듬을 제안한다.