• Title/Summary/Keyword: Multiple cavities

Search Result 54, Processing Time 0.021 seconds

Fabrication and optical characteristics of 50 ㎓ narrow band pass filter for fiber optical communication using dual ion beam sputtering technique (이중 이온빔 스퍼터링 방식을 사용한 채널 간격 50 ㎓ 광통신용 협대역 투과 필터의 제작 및 특성)

  • 김회경;김명진
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.331-337
    • /
    • 2003
  • This paper represents 50 ㎓ narrow band pass filters for fiber optical communication fabricated by dual ion beam sputtering method. We have analyzed the characteristics of the TA$_2$ $O_{5}$ and $SiO_2$ single layers in order to optimize the process conditions for the 50 ㎓ narrow band pass filters, and controlled the film thickness uniformity to less than 0.1 nm deviation by dual peak spike filter pre-deposition. We designed and fabricated 50 ㎓ narrow band pass filters that consist of 216 layers including 4 cavities based on quarter wave optical thickness. Class substrates with high thermal expansion coefficients were used to reduce the film stress. Anti-reflection coating at the rear side of the substrate was also needed to reduce the optical thickness errors of the Optical Monitoring System caused by multiple beam interference between the front side and the rear side of substrate. The optical characteristics of this 50 ㎓ narrow band pass filters are insertion loss of 0.40 ㏈, pass band ripple of 0.20 ㏈, and pass bandwidth at -0.5 ㏈ of 0.20 nm. and isolation bandwidth at -25 ㏈ of 0.6 nm, which satisfy specifications of dense WDM system in fiber optical communications.tions.

THE EFFECT OF INTERMITTENT COMPOSITE CURING ON MARGINAL ADAPTATION (복합레진의 간헐적 광중합 방법이 변연적합도에 미치는 영향)

  • Yun, Yong-Hwan;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.248-259
    • /
    • 2007
  • The aim of this research was to study the effect of intermittent polymerization on marginal adaptation by comparing the marginal adaptation of intermittently polymerized composite to that of continuously polymerized composite. The materials used for this study were Pyramid (Bisco Inc., Schaumburg, U.S.A.) and Heliomolar (Ivoclar Vivadent, Liechtenstein) . The experiment was carried out in class II MOD cavities prepared in 48 extracted human maxillary premolars. The samples were divided into 4 groups by light curing method: group 1- continuous curing (60s light on with no light off), group 2-intermittent curing (cycles of 3s with 2s light on & 1s light off for 90s); group 3- intermittent curing (cycles of 2s with 1s light on & 1s light off for 120s); group 4- intermittent curing (cycles of 3s with 1s light on & 2s light off for 180s). Consequently the total amount of light energy radiated was same in all the groups. Each specimen went through thermo-mechanical loading (TML) which consisted of mechanical loading (720,000 cycles, 5.0 kg) with a speed of 120 rpm for 100hours and thermocycling (6000 thermocycles of alternating water of $50^{\circ}C$ and $55^{\circ}C$). The continuous margin (CM) (%) of the total margin and regional margins, occlusal enamel (OE), vertical enamel (VE), and cervical enamel (CE) was measured before and after TML under a $\times200$ digital light microscope. Three-way ANOVA and Duncan's Multiple Range Test was performed at 95% level of confidence to test the effect of 3 variables on CM (%) of the total margin: light curing conditions, composite materials and effect of TML. In each group, One-way ANOVA and Duncan's Multiple Range Test was additionally performed to compare CM (%) of regions (OE, VE CE). The results indicated that all the three variables were statistically significant (p < 0.05). Before TML, in groups using Pyramid, groups 3 and 4 showed higher CM (%) than groups 1 and 2, and in groups using Heliomolar. groups 3 and 4 showed higher CM (%) than group 1 (p < 0.05). After TML, in both Pyramid and Heliomo)ar groups, group 3 showed higher CM (%) than group 1 (p < 0.05) CM (%) of the regions are significantly different in each group (p < 0.05). Before TML, no statistical difference was found between groups within the VE and CE region. In the OE region, group 4 of Pyramid showed higher CM (%) than group 2, and groups 2 and 4 of Heliomolar showed higher CM (%) than group 1 (p < 0.05). After TML, no statistical difference was found among groups within the VE and CE region. In the OE region, group 3 of Pyramid showed higher CM (%) than groups 1 and 2, and groups 2,3 and 4 of Heliomolar showed higher CM (%) than group 1 (p < 0.05). It was concluded that intermittent polymerization may be effective in reducing marginal gap formation.

BONDING OF RESIN INLAY TO GLASS-IONOMER BASE WITH VARIOUS TREATMENTS ON INLAY SURFACE (내표면 처리에 따른 레진 인레이와 글래스아이오노머 베이스간의 접착)

  • Jang, Byung-Sung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.399-406
    • /
    • 2000
  • The effect of inlay surface treatment on bonding was investigated when resin inlay was bonded to resin-modified glass-ionomer base with resin cement. For the preparation of glass-ionomer base, resin-modified glass-ionomer cement (Fuji II LC, GC Co., Japan) was filled in class I cavities of 7mm in diameter and 2mm in depth made in plastic molds. Eighty eight resin inlay specimens were made with Charisma$^{(R)}$ (Kulzer, Germany) and then randomly assigned to the four different surface treatment conditions: Group I, $50{\mu}m$ aluminium oxide sandblasting and silane treatment ; Group II, silane treatment alone ; Group III, sandblasting alone, and Group IV (control), no surface treatment. After a dentin bonding agent with primer (One-Step$^{TM}$, Bisco Inc., IL., U.S.A.) was applied to bonding surface of resin inlay and base, resin inlay were cemented to glass-ionomer base with a resin cement (Choice$^{TM}$, Bisco Inc., IL., U.S.A.). Shear bond strengths of each specimens were measured using Instron universal testing machine (4202 Instron, lnstron Co., U.S.A.) and fractured surfaces were examined under the stereoscope. Statistical analysis was done with one-way ANOVA and Dunkan's multiple range test. The results were as follows: 1. Sandblasting and silane treatment provided the greatest bond strength(10.56${\pm}$1.95 MPa), and showed a significantly greater bond strength than sandblasting alone or no treatment (p<0.05). 2. Silane treatment provided a significantly greater bond strength(9.77${\pm}$2.04 MPa) than sandblasting alone or no treatment (p<0.05). However, there was no significant difference in bond strength between sandblasting treatment and silane one (p>0.05). 3. Sandblasting alone provided no significant difference in bond strength from no treatment (p>0.05). 4. Stereoscopic examination of fractured surface showed that sandblasting and silane treatment or silane treatment alone had more cohesive failure mode than adhesive failure mode. 5. In relationship between shear bond strength and failure mode, cohesive failure occurred more frequently as bond strength increased.

  • PDF

Drug-Resistant Pulmonary Tuberculosis In Kosin Medical Center (부산지역의 한 3차 진료기관을 방문한 폐결핵 환자의 약제내성률)

  • Kim, Ji-Ho;Kim, Ji-Hong;Jang, Tae-Won;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.831-837
    • /
    • 1995
  • Background: We conducted a study to determine the factors associated with, patterns of, and proportion of cases of pulmonary tuberculosis with multiple drug-resistance at Kosin medical center in Pusan. Methods: We abstracted data from 141 patients, who had active pulmonary tuberculosis and report forms of drug susceptibility between 1986 and 1994, and related the previous treatment history, the extent of lung involvement and the presence of cavities on chest X-ray films to the drug resistance. Results: Overall, 59(41.8%) of the 141 cases of tuberculosis were resistant to at least one drug and 29(20.9%) of the 139 cases were resistant to isoniazid(INH) and rifampin(RIF). Among the 63 patients with previous tuberculosis therapy, 40(63.5%) had isolates that were drug-resistant and 24(38.1%) were multi-drug resistant. Among the 78 without previous therapy, 19(24.4%) had isolates that were drug-resistant and 5(7.5%) were multi-drug resistant. For all 141, resistance to INH was most common(39.0%) followed by RIF(21.6%), ethambutol(EMB, 16.3%), $\rho$- aminosalicylic acid(10.8%), streptomycin(SM, 8.7%), and pyrazinamide(PZA, 8.0%). INH, RIF and PZA resistances were independently associated with a history of previous tuberculosis therapy (odds ratio; 3.3, 7.2 and 10.8 respectively), and RIF and SM resistance were significantly high according to the extent of lung involvement on the chest films(odds ratio; 2.9 and 2.8 respectively). Conclusions: We conclude, (1) that all persons in whom pulmonary tuberculosis is diagnosed should initially receive at least four-drug therapy(INH, RIF, PZA, and EMB or SM), (2) that susceptibility testing be done in all culture-positive patient, and (3) that those with a history of previous tuberculosis therapy or those who have advanced pulmonary tuberculosis need very careful clinical and microbiological follow-up.

  • PDF