• 제목/요약/키워드: Multiple S-N curves

검색결과 11건 처리시간 0.024초

Fatigue Life Prediction of Laminated Composite Materials by Multiple S-N Curves and Lamina-Level Failure Criteria

  • Hangil You;Dongwon Ha;Young Sik Joo;Gun Jin Yun
    • Composites Research
    • /
    • 제36권1호
    • /
    • pp.42-47
    • /
    • 2023
  • In this paper, we present a fatigue life prediction methodology using multiple S-N curves according to the different stress states of laminated composites. The stress states of the plies of the laminated composites are classified into five modes: longitudinal tension or compression and transverse tension or compression, and shear according to the maximum stress criterion and Puck's criterion with a scaling factor K. This methodology has advantages in computational cost, and it can also consider microstructural characteristics of the composites by applying different S-N curves. The S-N curves for the fatigue analysis are obtained by experimental fatigue test. The proposed methodol is implemented into commercial software, ABAQUS user material subroutine and therefore, the fatigue analysis is conducted using the structural analysis results. The finite element (FE) simulation results are presented for unidirectional composites with and without open-hole. The FE simulation results show that the stress condition is different depending on the fiber orientation of the unidirectional composite, so the fatigue life is calculated with different S-N curves.

패킷 위성통신의 빔스위칭 요구할당 다중 접속 방식에 대한 성능 연구 (Performance on the Beam-Switched Demand Assigned Multiple Access for the Packet Satellite Communication)

  • 김덕년;김재명
    • 대한전자공학회논문지
    • /
    • 제26권10호
    • /
    • pp.1462-1470
    • /
    • 1989
  • This paper aims at investigating the Demand Assigned Multiple Access(DAMA) system for the packet-switched Satellite Communication. An onboard processor of the multisport beam satellite incorporates the ground controller to macimize the packet transmissions for each slot. 'Request Following' trnasmission mode is introduced as a transmission strategy of ground station under the control of its zone controller. The combined scheme of reservation channel access and contention channel access was proposed by Lee & Mark[3] for improving the Delay-Throughput performance. Our scheme provides less communication delay of approximately max. 200msec for achieving the corresponding throughput than the Lee & Mark's work does. Delay versus Throughput curves as well as Delay versus Traffic parameter curves are obtained. Numerical results obtained through the analysis and by the computer simulation show that the proposed scheme provides the low average packer delay even under the condition that the number of transponders (M)is below the half of the number of zones(N).

  • PDF

붓스트랩방법을 이용한 피로모형의 설계곡선 설정 (Construction of a Design Curve for Fatigue Model Using Bootstrap Method)

  • 서순근;조유희
    • 품질경영학회지
    • /
    • 제30권4호
    • /
    • pp.106-119
    • /
    • 2002
  • The fatigue curve with estimated parameters represents the estimate of the median or mean life at a given applied stress But, in order to assist a designer in making decisions regarding the fatigue failure mode, it is common practice to construct a design curve on the lower or safe side of data. In this study, to overcome the limitations(i.e., no runout, equal variance, and quality of the approximation, etc) of Shen, Wirsching, and Cashman's method which suggested the approximate design curve for nonlinear models using tolerance interval constructed by Owen's method, an algorithm to find design curves under the fatigue model using a parametric bootstrap method, is proposed and illustrated with multiple fatigue data sets.

이온선택성 멤브레인을 이용한 양액 내 질산태 질소 및 칼륨 측정 (Sensing NO3-N and K Ions in Hydroponic Solution Using Ion-Selective Membranes)

  • 김원경;박두산;김영주;노미영;조성인;김학진
    • Journal of Biosystems Engineering
    • /
    • 제35권5호
    • /
    • pp.343-349
    • /
    • 2010
  • Rapid on-site sensing of nitrate-nitrogen and potassium ions in hydroponic solution would increase the efficiency of nutrient use for greenhouse crops cultivated in closed hydroponic systems while reducing the potential for environmental pollution in water and soil. Ion-selective electrodes (ISEs) are a promising approach because of their small size, rapid response, and the ability to directly measure the analyte. The capabilities of the ISEs for sensing nitrate and potassium in hydroponic solution can be affected by the presence of other ions such as calcium, magnesium, sulfate, sodium, and chloride in the solution itself. This study was conducted to investigate the applicability of two ISEs consisting of TDDA-NPOE and valinomycin-DOS PVC membranes for quantitative determinations of $NO_3$-N and K in hydroponic solution. Nine hydroponic solutions were prepared by diluting highly concentrated paprika hydroponic solution to provide a concentration range of 3 to 400 mg/L for $NO_3$-N and K. Two of the calibration curves relating membrane response and nutrient concentration provided coefficients of determination ($R^2$) > 0.98 and standard errors of calibration (SEC) of < 3.79 mV. The use of the direct potentiometry method, in conjunction with an one-point EMF compensation technique, was feasible for measuring $NO_3$-N and K in paprika hydroponic solution due to almost 1:1 relationships and high coefficients of determination ($R^2$ > 0.97) between the levels of $NO_3$-N and K obtained with the ion-selective electrodes and standard instruments. However, even though there were strong linear relationships ($R^2$ > 0.94) between the $NO_3$-N and K concentrations determined by the Gran's plot-based multiple standard addition method and by standard instruments, hydroponic $NO_3$-N concentrations measured with the ISEs, on average, were about 10% higher than those obtained with the automated analyzer whereas the K ISE predicted about 59% lower K than did the ICP spectrometer, probably due to no compensation for a difference between actual and expected concentrations of standard solutions directly prepared.

Emission and Structural Properties of Titanium Oxide Nanoparticles-coated a-plane (11-20) GaN by Spin Coating Method

  • Kim, Ji-Hoon;Son, Ji-Su;Baik, Kwang-Hyeon;Park, Jung-Ho;Hwang, Sung-Min
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.146-146
    • /
    • 2011
  • The blue light emitting diode (LED) structure based on non-polar a-plane (11-20) GaN which was coated TiO2 nanoparticles using spin coating method was grown on r-plane (1-102) sapphire substrates to improve light extraction efficiency. We report on the emission and structural properties with temperature dependence of photoluminescence (PL) and x-ray rocking curves (XRC). From PL results at 13 K of undoped GaN samples, basal plane stacking fault (BSF) and near band edge (NBE) emission peak were observed at 3.434 eV and 3.484 eV, respectively. We also found the temperature-induced band-gap shrinkage, which was fitted well with empirical Varshini's equation. The PL intensity of TiO2 nanoparticles ?coated multiple quantum well (MQW) sample is decayed slower than that of no coating sample with increasing temperature. The anisotrophic strain and azimuth angle dependence in the films were shown from XRC results. The full width at half maximum (FWHM) along the GaN [11-20] and [1-100] directions were 564.9 arcsec and 490.8 arcsec, respectively. A small deviation of FWHM values at in-plane direction is attributed to uniform in-plane strain.

  • PDF

ESI-MS/MS를 이용한 소변 중 Globotriaosylceramide(Gb3)의 정량 및 임상 응용; 패브리병(Fabry) 진단 (Method Development for the Profiling Analysis of Urine Globotriaosylceramide (Gb3) for the Screening of Fabry Disease by Tandem Mass Spectrometry)

  • 윤혜란;조경희;강승우;권영주;정춘식;이용수
    • 약학회지
    • /
    • 제51권2호
    • /
    • pp.96-102
    • /
    • 2007
  • Measurement of globotriaosylceramide (Gb3, ceramide trihexoside) in urine has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. A simple, rapid, and highly sensitive analytical method for Gb3 in urine was developed without labor-extensive pre-treatment by electrospray ionization MS/MS (ESI-MS/MS). Only simple 5-fold dilution of urine is necessary for the extraction and isolation of Gb3 in urine. Gb3 in diluted urine was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Eight isoforms of Gb3 were completely resolved from urine matrix. C24:0 Gb3 occupied 50% of total Gb3 as a major component in urine. Linear relationship for Gb3 isoforms was found in the range of 0.005${\sim}$5.0 ${\mu}$g/ml. The limit of detection (S/N=5) was 0.005 ${\mu}$g/ml and limit of quantification was 0.05 ${\mu}$g/ml for C24:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9598 to 0.9975. This method could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

HPLC-MS/MS를 이용한 트리클로로에틸렌 대사산물의 다중 분석법 확립 (Multiple Determinations of Trichloroethylene Metabolites in a Concurrent Biological Media using High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry)

  • 안영아;고영림;이승호;신미연;전중대;김성균
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.114-126
    • /
    • 2014
  • Objectives: We aimed to develop a measurement method of five metabolites of trichloroethylene (TCE) in a concurrent biological sample, e.g., trichloroacetic acid (TCA), dichloroacetic acid (DCA), S-(1,2-dichlorovinyl) glutathione (DCVG), S-(1,2-dichlorovinyl)-L-cysteine (DCVC), and N-Acetyl-S-(1,2-dichlorovinyl)-L-cysteine (NAcDCVC) and to validate the method before application to pharmacokinetic study. Methods: TCE metabolites were simultaneously analyzed using high performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS/MS) with as little as 50 ${\mu}L$ of serum and urine. DCA, TCA and NAcDCVC were extracted with diethyl ether, while DCVC and DCVG were extracted by solid phase extraction. This method was validated according to the guidelines for bioanalytical method validation of the Korean National Institute of Toxicological Research. Then, we determined the five metabolites in five strains of mice at 24 hr after exposure to 1 g TCE /kg body weight. Results: The limits of detection for the five metabolites in biological samples ranged from 0.001 to 0.076 nmol/mL, which is comparable to or better than those previously reported. Most calibration curves showed good linearity ($R^2=0.99$), and between-batch variation was less than 20% expressing acceptable robustness and reproducibility. Using this method, we found TCA and DCA were detected in all test mice at 24 hr after the oral administration while NAcDCVC and DCVC were detected in some strains, which showed strain-dependent metabolism of TCE. Conclusions: The present method could provide robust and accurate measurements of major key metabolites of TCE in biological media, which allowed concurrent analysis of TCE metabolism for limited amounts of biospecimens.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

한국중년층에서 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 심장혈관계질환 위험인자 타당도 비교 (Comparing validity of using Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Risk Factors of Middle Aged Koreans)

  • 문현경;김유진
    • 대한영양사협회학술지
    • /
    • 제11권3호
    • /
    • pp.365-374
    • /
    • 2005
  • This study was conducted to compare the validity of obese index among body mass index(BMI), waist to hip ratio(WHR), and waist circumference(WC) and to determine which is the best in relation to cardiovascular risk factors of middle aged Korean(40-64yr).Data from the 1998 Korean Health and Nutrition Survey were used(N=3380). Anthropometric indices and cardiovascular risk factors were measured. Chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator characteristic(ROC) curves were used in the analysis. There was a significant increasing trend in WHR, systolic blood pressure(SBP), high density lipoprotein cholesterol(HDL), and fasting blood sugar(FBS) with age categories of male and in BMI, WC, WHR, diastolic blood pressure(DBP), SBP, total cholesterol(TC), low density lipoprotein cholesterol(LDL), triglycerol(TG), and FBS with those of female. Specially female had the characteristics of upper body fat and systolic blood pressure risk(p<0.05). Proportions of subjects with lifestyle factors related to cardiovascular risk in overweight or upper body fat group were higher than that of normal group. Higher proportions of subjects were practiced exercise in upper body fat group of male than in other groups. Among 7 cardiovascular risk factors in partial correlation analysis, BMI had the highest correlation coefficient in 6 risk factors in male, whereas WC in 4 risk factors in female. Mean of each obese index according to cardiovascular risk groups except smoker was higher than that of normal(p<0.05). These trends were shown in upper body fat group and female. In ROC analysis of 12 risk factors and health conditions, the largest area under curve among obese indices for risk factors were BMI in male and WHR in female. The optimal cutoff values of each index(BMI: WHR: WC) for one or more cardiovascular risk factors were 23.13: 0.89: 85.35 in male and 23.57: 0.84: 78.35 in female. The results showed that cardiovascular risk factors were prevalent in middle aged Koreans within normal limits of obese indices like another Asians. For the identification of cardiovascular risk factors of middle aged Koreans, BMI for men and WHR for women are appropriate indices. But it is recommended that BMI, WHR, and WC, all three indices should be considered, when using these indices.

  • PDF

한국노인에서 심장혈관계 질환 위험인자에 대한 비만지표인 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 타당도 비교 (Comparing Validity of Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Disease Risk Factors in Korean Elderly)

  • 문현경;김유진
    • Journal of Nutrition and Health
    • /
    • 제38권6호
    • /
    • pp.445-454
    • /
    • 2005
  • The purpose of this study was to compare the validity of obese index among body mass index (BMI), waist to hip ratio (WHR), and waist circumference (WC) and to determine which is the best in relation to cardiovascular disease (CVD) risk in Korean elderly more than 65 ages. Data from the 1998 Korean Health and Nutrition Survey were used (n=1017). Anthropometric indices and CVD risk factors were measured, and chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator Characteristic (ROC) curves were used in the analysis. Anthropometric values were decreased in both male and female when ages were goes up. In female elderly, it specially showed the characteristics of upper body fat and systolic blood pressure risk (p<0.05). Among life style factors the current smokers were prevalent in obese male (p<0.05), but not prevalent in female having obese or upper body fat. Also, person with upper body obesity have more exercise than that of normal group (p<0.01). Mean BMI values of the current smoker was lower than that of normal group in both sexes (p<0.01). Mean BMI value of person with other risk factors were higher than that of normal groups (p<0.05). Among 7 CVD risk factors in partial correlation analysis, WC had the highest correlation coefficient in 5 in male, whereas BMI in 4 in female. In ROC analyses of 12 risk factors and health conditions, the largest area under curve of obese indices for risk factors were WC>WHR>BMI in male and BMI>WHR>WC in female. The optimal cutoff values of each index (BMI : WHR : WC) for one or more risk factors were 19.02 : 0.84 : 71.3 in male and 19.04 : 0.88 : 85.6 in female. In conclusion, Most Korean elderly showed non-obese and abdominal obesity likewise other Asians. Also CVD risk factors were prevalent in Korean elderly within normal limits of obese indices. Therefore the upper body fat indices reflected in the aged whose muscle mass is replaced by fat must be used as an indicator of CVD risk together with BMI. Although WHR was the worst index based on partial correlation analysis and so located between BMI and WC in ROC curve analysis in both sexes, it need to be use with WC to screen the cardiovascular risk group.