• 제목/요약/키워드: Multiple Grid

검색결과 306건 처리시간 0.022초

Islanding Detection Method for Inverter-based Distributed Generation Systems using a Signal Cross-correlation Scheme

  • Bae, Byung-Yeol;Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.762-768
    • /
    • 2010
  • This paper describes the development of a new islanding detection method for inverter-based distributed generation systems, which uses a signal cross-correlation scheme between the injected reactive current and the power frequency deviation. The proposed method injects 1% of the reactive current to the rated current which brings about a negligible degradation of the power quality. It discriminates the islanding state, when the calculated cross-correlation index is larger than 0.5. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software and experimental research with a hardware prototype. The proposed method can detect the islanding state without degrading the power quality at the point of common connection. Further study is required to overcome the cancellation of the injected reactive current from multiple distributed generation units interconnected with the utility grid.

Parallel Control of Shunt Active Power Filters in Capacity Proportion Frequency Allocation Mode

  • Zhang, Shuquan;Dai, Ke;Xie, Bin;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.419-427
    • /
    • 2010
  • A parallel control strategy in capacity proportion frequency allocation mode for shunt active power filters (APFs) is proposed to overcome some of the difficulties in high power applications. To improve the compensation accuracy and overall system stability, an improved selective harmonic current control based on multiple synchronous rotating reference coordinates is presented in a single APF unit, which approximately implements zero steady-state error compensation. The combined decoupling strategy is proposed and theoretically analyzed to simplify selective harmonic current control. Improved selective harmonic current control forms the basis for multi-APF parallel operation. Therefore, a parallel control strategy is proposed to realize a proper optimization so that the APFs with a larger capacity compensate more harmonic current and the ones with a smaller capacity compensate less harmonic current, which is very practical for accurate harmonic current compensation and stable grid operation in high power applications. This is verified by experimental results. The total harmonic distortion (THD) is reduced from 29% to 2.7% for a typical uncontrolled rectifier load with a resistor and an inductor in a laboratory platform.

이미지 센서와 3축 가속도 센서를 이용한 인간 행동 인식 (Human Activity Recognition using an Image Sensor and a 3-axis Accelerometer Sensor)

  • 남윤영;최유주;조위덕
    • 인터넷정보학회논문지
    • /
    • 제11권1호
    • /
    • pp.129-141
    • /
    • 2010
  • 본 논문에서는 사람의 행동 모니터링을 위한 멀티 센서 기반의 웨어러블 지능형 디바이스를 제안한다. 다중 행동을 인식하기 위해, 이미지 센서와 가속도 센서를 이용하여 행동 인식 알고리즘을 개발하였다. 멀티 센서로부터 얻은 데이터를 분석하기 위해 그리드 기반 옵티컬 플로우 방법을 제안하고 SVM 분류기법을 이용하였다. 이미지 센서로부터 얻은 모션 벡터의 방향과 크기를 이용하였고, 3축 가속도 센서로부터 얻은 데이터에서 FFT의 축과 크기와의 상관관계를 계산하였다. 실험 결과에서 이미지 센서 기반과 3축 가속도 센서기반의 행동 인식률은 각각 55.57 %, 89.97%를 보였으나 제안한 멀티센서기반의 행동인식률은 92.78% 를 보였다.

가상 네트워크 환경에 기반한 모바일 네트워크 (Miblie Network based on Virtual Network environment)

  • 이종서;문일영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.793-794
    • /
    • 2009
  • 최근에는 컴퓨팅 자원이 크게 증가하여, 인터넷을 통해 연결된 수많은 컴퓨팅 자원들을 다수의 사용자가 이용하고 어떻게 서비스 할 것인가에 대한 클라우드 컴퓨팅 또는 그리드 컴퓨팅 기술이 주목받고 있으며 또한 네트워크에서도 물리적 네트워크 위에 가상의 네트워크 링크와 노드을 구성하여 가상의 네트워크를 구성하는 가상 네트워크 환경 연구가 이뤄지고 있다. 가상화 기술은 네트워크 보다는 실질적으로 운영체제 분야에서 오랫동안 연구되고 발전되고 있으나 본 논문에서는 네트워크 분야에 적용된 가상화기술을 토대로 모바일 네트워크에 적용된 가상 모바일 네트워크에 대하여 살펴보도록 하겠다.

  • PDF

Impact onto an Ice Floe

  • Khabakhpasheva, Tatyana;Chen, Yang;Korobkin, Alexander;Maki, Kevin
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.146-162
    • /
    • 2018
  • The unsteady problem of a rigid body impact onto a floating plate is studied. Both the plate and the water are at rest before impact. The plate motion is caused by the impact force transmitted to the plate through an elastic layer with viscous damping on the top of the plate. The hydrodynamic force is calculated by using the second-order model of plate impact by Iafrati and Korobkin (2011). The present study is concerned with the deceleration experienced by a rigid body during its collision with a floating object. The problem is studied also by a fully-nonlinear computational-fluid-dynamics method. The elastic layer is treated with a moving body-fitted grid, the impacting body with an immersed boundary method, and a discrete-element method is used for the contact-force model. The presence of the elastic layer between the impacting bod- ies may lead to multiple bouncing of them, if the bodies are relatively light, before their interaction is settled and they continue to penetrate together into the water. The present study is motivated by ship slamming in icy waters, and by the effect of ice conditions on conventional free-fall lifeboats.

배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상 (Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line)

  • 이상훈;김수빈;송승호
    • 풍력에너지저널
    • /
    • 제9권4호
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

STARS: A 3D GRID-BASED MONTE CARLO CODE FOR RADIATIVE TRANSFER THROUGH RAMAN AND RAYLEIGH SCATTERING WITH ATOMIC HYDROGEN

  • Chang, Seok-Jun;Lee, Hee-Won
    • 천문학회지
    • /
    • 제53권6호
    • /
    • pp.169-179
    • /
    • 2020
  • Emission features formed through Raman scattering with atomic hydrogen provide unique and crucial information to probe the distribution and kinematics of a thick neutral region illuminated by a strong far-ultraviolet radiation source. We introduce a new 3-dimensional Monte-Carlo code in order to describe the radiative transfer of line photons that are subject to Raman and Rayleigh scattering with atomic hydrogen. In our Sejong Radiative Transfer through Raman and Rayleigh Scattering (STaRS) code, the position, direction, wavelength, and polarization of each photon is traced until escape. The thick neutral scattering region is divided into multiple cells with each cell being characterized by its velocity and density, which ensures flexibility of the code in analyzing Raman-scattered features formed in a neutral region with complicated kinematics and density distribution. To test the code, we revisit the formation of Balmer wings through Raman scattering of the far-UV continuum near Lyβ and Lyγ in a static neutral region. An additional check is made to investigate Raman scattering of O vi in an expanding neutral medium. We find a good agreement of our results with previous works, demonstrating the capability of dealing with radiative transfer modeling that can be applied to spectropolarimetric imaging observations of various objects including symbiotic stars, young planetary nebulae, and active galactic nuclei.

Tension-Shear Experimental Analysis and Fracture Models Calibration on Q235 Steel

  • Huang, Xiaogang;Zhou, Zhen;Zhu, Yazhi;Zhu, Dongping;Lu, Lu
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1784-1800
    • /
    • 2018
  • Tension-shear loading is a common loading condition in steel structures during the earthquake shaking. To study ductile fracture in structural steel under multiple stress states, experimental investigations on the different fracture mechanisms in Chinese Q235 steel were conducted. Different tension-shear loading conditions achieved by using six groups of inclined notch butterfly configurations covering pure shear, tension-shear and pure tension cases. Numerical simulations were carried out for all the specimens to determine the stress and strain fields within the critical sections. Two tension-shear fracture models were calibrated based on the hybrid experimental-numerical procedure. The equivalent fracture strain obtained from the round bar under tensile loading was used for evaluating these two models. The results indicated that the tension-shear criterion as a function of the shear fracture parameter had better performance in predicting the fracture initiation of structural steel under different loading conditions.

국내 배전망 정책 및 환경변화를 고려한 배전부분 발전방향 연구 (KEPCO's Movement on Distribution Sector Regarding Renewable Energy Transition of Distribution Network in Korea)

  • Hyun, Seung-Yoon;Kim, Chang-Hwan;Lee, Byung-Sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.93-99
    • /
    • 2021
  • The government has proposed a mission to enhance intelligent power networks, decrease coal-fired generation, expand distributed energy resources, and promote energy prosumer into the distribution network in Korea. Installation cost of facility expansion to guaranteed interconnection with small distributed energy resources increases dramatically on KEPCO's distribution sector. And it is hard to withdraw in time. In addition, there are explicit research is required to meet the reliability on grid corresponding to the increase of distributed power. Infrastructure support for accommodating energy prosumer is also needed. Therefore, KEPCO is pushing transition to DSO by expanding distribution management scope and changing its roles. In addition, KEPCO is proactively preparing for integrated operation between distribution network and existing distributed power which is accommodated passively. KEPCO is also trying to accept multiple network users, e.g. building platforms, to manage a data and promote new markets. In the long term, transition to DSO will achieve saving investment costs for accommodating distributed sources and maintaining stable electrical quality. And it will be possible to create new business model using the platform to secure revenue.

Numerical investigation on the wave interferences of submerged bodies operating near the free surface

  • Li, Dong;Yang, Qun;Zhai, Lin;Wang, Zhen;He, Chuan-lin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.65-74
    • /
    • 2021
  • A key factor that governs the wave interferences of a submerged body is the dimensionless Froude number. Computational Fluid Dynamics (CFD) is used to describe the resistance force coefficients and the generated waves of two SUBOFF submarine models. Grid independence studies are performed on two cases, totally and shallowly submerged cases, with four sets of computing meshes. The highest peaks are marked by red points at given wavelengths, a line is fitted to those points with a least-squares approximation, and the half wake angle at multiple Froude numbers is defined between the fitted line and the centerline of the free surface. The results show that when the depth of the target is 1.1D, constructive interferences occur at Fn = 0.3 and 0.5, while destructive interference occurs at Fn = 0.35 with distortion of the waveform. The half wake angle is less than 19.47° because of the interference between the bow and stern wave systems.