• Title/Summary/Keyword: Multi-winding

검색결과 138건 처리시간 0.03초

여자 방식에 따른 다권선 LDM의 특성 해석 (Characteristics Analysis of multi-separated winding LDM by Excitation Mode)

  • 김재필;백수현;맹인재;우영수;김일남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.804-806
    • /
    • 2001
  • In this paper, by designing ratio width of the permanent magnet versus the stator coil, double excitation LDM with multi-separated winding which is possible to obtain the constant thrust force is proposed. Using Empulse, this paper has explained a various excitation mode to analyze the thrust force of multi-separated winding LDM. The simulation results show single-phase excitation mode have low thrust force ripple.

  • PDF

Tap Level 제어 전력 변환기의 권선설계 (A winding design of Tap Level Converter)

  • 전중함;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.53-55
    • /
    • 2006
  • In this paper discusses winding methode of single phase AC-DC reversible power converter The reversible power converter driven by multi Tap winding at both side switching control. It has a advantage that simple drive of main switching device. and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

Comparison of High Frequency Detailed Generator Models for Partial Discharge Localization

  • Hassan Hosseini, S.M.;Hosseini Bafghi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1752-1758
    • /
    • 2015
  • This paper presents partial discharge localization in stator winding of generators using multi-conductor transmission line (MTL) and RLC ladder network models. The high-voltage (HV) winding of a 6kV/250kW generator has been modeled by MATLAB software. The simulation results of the MTL and the RLC ladder network models have been evaluated with the measurements results in the frequency domain by applying of the Pearson’s correlation coefficients. Two PD generated calibrator signals in kHz and MHz frequency range were injected into different points of generator winding and the signals simulated/measured at the both ends of the winding. For partial discharge localization in stator winding of generators is necessary to calculate the frequency spectrum of the PD current signals and then estimate the poles of the system from the calculated frequency spectrum. Finally, the location of PD can be estimated. This theory applied for the above generator and the simulation/measured results show the good correlation for PD Location for RLC ladder network and MTL models in the frequency range of kHz (10kHz<f<1MHz) and MHz (1MHz<f<5MHz) respectively.

Multi-Level Operation with Two-Level Converters through a Double-Delta Source Connected Transformer

  • Park, Yongsoon;Ohn, Sungjae;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1093-1099
    • /
    • 2014
  • This paper proposes a power conversion topology involving a multi-winding transformer and converters. The fundamental idea is described with circuit diagrams, and the voltage output of the proposed topology is analyzed mathematically. The effectiveness of the topology is discussed with test results from a small-scale power conversion system. When conventional hardware consisting of two-level converters and a transformer is employed, multi-level voltage outputs can be applied to the transformer windings by the proposed method.

열-기계적 시험에 따른 초고압 폴리머 부싱의 굽힘변형 및 기밀성능에 관한 연구 (Performance of Sealing Integrity and Banding strain of HV Polymeric bushing with Thermal Mechanical Test)

  • 조한구;유대훈;강형경;이철호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1441_1441
    • /
    • 2009
  • This paper describes performance of sealing integrity and bending strain of HV polymeric bushing with thermal mechanical test. Generally the properties of FRP tube can be influenced by the winding angle, wall thickness and winding tension. As a results, multi winding bushing shows that it has max deflection in the range of 16.5~16.9 mm.

  • PDF

전류환류형 DC-DC 콘버터를 이용한 새로운 다출력회로 (THE NEW MULTI-OUTPUT DC-DC CONVERTER USING THE CURRENT-FED CONVERTER)

  • 안태영;이윤종;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.144-147
    • /
    • 1988
  • The current-fed DC-DC converter, which is known as the most stable DC-DC converter, has a two-winding reactor in series with the input. In this paper the new multi-output DC-DC converter circuit, in which the 2nd winding of the reactor is creating the 2nd output, while the 2nd winding is feeding the energy to input in the current-fed converter, is proposed. The steady state characteristics of the new circuit are clarified. And it is found that the maximum value exists in the 2nd output.

  • PDF

양측여자형 LDM의 특성해석을 위한 고정자 권선법 (Stator Winding for Characteristic Analysis of Double Sided Excitation LDM)

  • 우영수;백수현;맹인제;홍순찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-134
    • /
    • 2001
  • In this paper, by designning the width of the stator coil, double sided excitation LDM with multi-separated winding which is possible to obtain the constant thrust force is proposed. Using Maxwell 2D, Empulse, we were proved the characteristic analysis of LDM accoding to ratio magnet width venus coil width of LDM. Though designning for double sided excitation LDM with multi-separated winding, we could be achieved the constant thrust and rapidly time responses within the operating region.

  • PDF

단일 2차측 권선을 이용한 다중 출력용 새로운 PWM DC/DC 컨버터 회로 (A New PWM DC/DC Converter Topology with Multi-Output Using Single Secondary Winding)

  • 이동윤;현동석;최익;송중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1339-1341
    • /
    • 2000
  • This paper presents a new PWM DC/DC converter with multi-output using single secondary winding, which has two output characteristics of the isolation and non-isolation simultaneously. The proposed converter topology is consisted of the only one switch and single secondary winding. The proposed converter, therefore, has advantages not only low cost but also high power density. Operating principal of the proposed converter topology with conventional ZVT (Zero-Voltage-Transition) is illustrated in detail and the validity of the converter is verified with several interesting simulation results.

  • PDF

고온초전도 적층선재의 특성과 적층선재로 제작한 팬케이크 권선 손실 (Characteristics of the HTS Stacked Tapes and AC Losses of the Multi-Stacked Pancake Coil)

  • 이승욱;임형우;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.658-663
    • /
    • 2004
  • According to the improvement of the HTS wires performance, several tapes of HTS superconducting machines are being developed. Stacked HTS tapes are used as conductor that can flow high current for the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external filed and AC losses should be examined. In this paper, we present characteristic of the stacked HTS tapes and AC losses of HTS pancake windings with stacked tapes. AC loss of the pancake winding were measured and compared with the calculated loss by using AC loss data of the stacked samples and the magnetic flux density in the HTS winding under operating conditions. We can see that measured results generally agree well with the calculated results by using AC loss data of 4-stacked sample.

Analysis of Generalized n-winding Coupled Inductor in dc-dc Converters

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.88-89
    • /
    • 2017
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of multi-winding coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/n, 2/n, … or (n1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one.

  • PDF