• Title/Summary/Keyword: Multi-variable system

검색결과 450건 처리시간 0.051초

A Dual-Mode 2.4-GHz CMOS Transceiver for High-Rate Bluetooth Systems

  • Hyun, Seok-Bong;Tak, Geum-Young;Kim, Sun-Hee;Kim, Byung-Jo;Ko, Jin-Ho;Park, Seong-Su
    • ETRI Journal
    • /
    • 제26권3호
    • /
    • pp.229-240
    • /
    • 2004
  • This paper reports on our development of a dual-mode transceiver for a CMOS high-rate Bluetooth system-onchip solution. The transceiver includes most of the radio building blocks such as an active complex filter, a Gaussian frequency shift keying (GFSK) demodulator, a variable gain amplifier (VGA), a dc offset cancellation circuit, a quadrature local oscillator (LO) generator, and an RF front-end. It is designed for both the normal-rate Bluetooth with an instantaneous bit rate of 1 Mb/s and the high-rate Bluetooth of up to 12 Mb/s. The receiver employs a dualconversion combined with a baseband dual-path architecture for resolving many problems such as flicker noise, dc offset, and power consumption of the dual-mode system. The transceiver requires none of the external image-rejection and intermediate frequency (IF) channel filters by using an LO of 1.6 GHz and the fifth order onchip filters. The chip is fabricated on a $6.5-mm^{2}$ die using a standard $0.25-{\mu}m$ CMOS technology. Experimental results show an in-band image-rejection ratio of 40 dB, an IIP3 of -5 dBm, and a sensitivity of -77 dBm for the Bluetooth mode when the losses from the external components are compensated. It consumes 42 mA in receive ${\pi}/4-diffrential$ quadrature phase-shift keying $({\pi}/4-DQPSK)$ mode of 8 Mb/s, 35 mA in receive GFSK mode of 1 Mb/s, and 32 mA in transmit mode from a 2.5-V supply. These results indicate that the architecture and circuits are adaptable to the implementation of a low-cost, multi-mode, high-speed wireless personal area network.

  • PDF

고체연료를 사용하는 가스발생기 유량조절특성 연구 (Characteristics of Flow Rate Control for Solid Fuel Gas Generator)

  • 최호진;현형수;이경호;박익수;이재윤;윤현걸;임진식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.293-298
    • /
    • 2011
  • 덕티드로켓 추진기관에 사용되는 불완전연소 가스발생기 및 유량조절시스템을 설계/제작하고 연소시험을 수행하여 유량조절특성을 분석하였다. 추진시스템 설계요구조건을 바탕으로 가스발생기를 설계하고 불완전연소용 고체연료 조성을 개발하여 연소시험을 수행, 일반적인 고체추진기관 해석모델을 통한 예측결과와 상당한 차이의 실험결과로부터 불완전 연소가스를 위한 별도의 해석모델이 요구됨을 확인하였다. 유량조절 시험을 통해 밸브각도에 따른 가스발생기 압력변화 특성을 확인하였고, 출구면적에 따라 유일하게 결정되는 유출계수로부터 가스발생기 압력을 예측하는 방법을 도출하였다.

  • PDF

난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode)

  • 강훈;정현준;주영주;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

동시냉난방 열펌프의 전열회수 성능 특성에 관한 연구 (Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Heat Recovery Mode)

  • 최종민;정현준;주영주;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.718-726
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a simultaneous heating and cooling heat pump was investigated in the heat recovery mode (HR mode). The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the HR mode, the capacity and COP were improved as compared with those in the cooling or heating mode because the waste heat in the outdoor unit was utilized as useful heat in the indoor units. However, energy imbalance between heating and cooling capacity of each indoor unit was observed in the 2H-1C HR mode. Therefore, the performance of the system in the 2H-1C HR mode was enhanced by controlling refrigerant flow rate through the outdoor unit.

배열 안테나 기반 협대역 간섭신호 제거를 위한 저면적 FFT 프로세서 설계 연구 (Design of Low-complexity FFT Processor for Narrow-band Interference Signal Cancellation Based Array Antenna)

  • 양기정;원현희;박성열;안병선;강행익
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.621-622
    • /
    • 2017
  • 본 논문에서 배열 안테나 기반 협대역 간섭신호 제거를 위한 저면적 FFT 프로세서 구조를 제안하고 5채널 64/128/512-point FFT 프로세서를 하드웨어로 구현 및 검증하였다. 제안된 flexible-Multipah Delay Commutator(MDC) 방식을 이용하여 5채널 입력 데이터를 하나의 FFT 프로세서로 처리했으며, 제안된 Mixed Radic-4/2/4/2/4/2 분해 방법을 통해 복잡도 측면에서 가장 큰 비중을 차지하는 비단순 승산의 수를 줄임으로써 복잡도를 크게 낮추었다. 제안된 FFT 프로세서는 Xilinx system generator로 설계한 후, Xilinx Virtex-7 FPGA에 기반하여 구현하였다. 구현 결과 slices 17508개, DSP48s(dedicated multiplier) 108개로 구현 가능함을 확인하였다.

  • PDF

RIS Selection and Energy Efficiency Optimization for Irregular Distributed RIS-assisted Communication Systems

  • Xu Fangmin;Fu Jinzhao;Cao HaiYan;Hu ZhiRui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권7호
    • /
    • pp.1823-1840
    • /
    • 2023
  • In order to improve spectral efficiency and reduce power consumption for reconfigurable intelligent surface (RIS) assisted wireless communication systems, a joint design considering irregular RIS topology, RIS on-off switch, power allocation and phase adjustment is investigated in this paper. Firstly, a multi-dimensional variable joint optimization problem is established under multiple constraints, such as the minimum data requirement and power constraints, with the goal of maximizing the system energy efficiency. However, the proposed optimization problem is hard to be resolved due to its property of nonlinear nonconvex integer programming. Then, to tackle this issue, the problem is decomposed into four sub-problems: topology design, phase shift adjustment, power allocation and switch selection. In terms of topology design, Tabu search algorithm is introduced to select the components that play the main role. For RIS switch selection, greedy algorithm is used to turn off the RISs that play the secondary role. Finally, an iterative optimization algorithm with high data-rate and low power consumption is proposed. The simulation results show that the performance of the irregular RIS aided system with topology design and RIS selection is better than that of the fixed topology and the fix number of RISs. In addition, the proposed joint optimization algorithm can effectively improve the data rate and energy efficiency by changing the propagation environment.

슬래브 두께가 다른 다층지지 RC 구조 시스템에서의 슬래브 시공 하중 분포 (Slab Construction Load Distribution in a Multistory-shored RC Structure System with Different Slab Thickness)

  • 한상민;김재요
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권2호
    • /
    • pp.17-26
    • /
    • 2024
  • 최근 콘크리트 타설 중 구조체, 거푸집 및 동바리 사고가 계속해서 발생하고 있으며, 특히 슬래브 두께가 증가하는 다층지지 RC 구조에서 붕괴 사고가 빈번하게 발생하였다. 이전 연구에서는 모든 슬래브 두께가 일정한 경우에 대한 연구가 주로 수행되었으나 일부 슬래브의 두께가 다른 경우, 슬래브 단면 강성의 변화로 전체 슬래브 강성 비율이 달라져 시공 하중의 분포가 달라질 수 있어 이에 대한 연구가 요구된다. 이 연구에서는 슬래브 두께를 변수로 설정하여 슬래브 두께 변화가 콘크리트 강성과 구조물에 미치는 영향을 고려하여 시공 하중의 분포를 분석하였으며, 슬래브 두께가 변화하는 경우 콘크리트 재료 강성 뿐만이 아닌 슬래브 단면 강성도 시공 하중 산정에 고려되어야 함을 확인하였다. 슬래브 두께가 증가 할 경우 두께가 증가하는 층에 작용하는 최대 시공 하중과 최대 손상 변수는 크게 증가하였으며 두께 증가가 클수록 더욱 높은 비율의 시공 하중이 작용함을 확인하였다.

ATM 네트워크에서 멀티 룰-베이스 기법을 이용한 트래픽 제어 (Traffic Control using Multi Rule-Base in an ATM Network)

  • 김영일;류인태;심철;이상배
    • 한국통신학회논문지
    • /
    • 제18권12호
    • /
    • pp.1870-1883
    • /
    • 1993
  • 본 논문에서는 ATM 방식으로 운용되는 사용자 네트워크를 구축하기 위해서 필수적인 주요 기능 그룹들-B-TE, B-NT2, LEX-이 수행하여야할 트래픽 제어기법에 대하여 연구한다. 사용자 네트워크에서 가장 중요한 기능 그룹인 B-NT2의 구성을 매우 단순화하여 정의한다. 또한 LEX의 구성기능 역시 B-NT2와 유사하게 정의한다. 가상 경로 식별자를 트래픽의 특성별로 고정할당하여 전체적인 트래픽 제어 기능의 분산을 가능하게 한다. 트래픽 제어를 위하여 연결수작 제어, 사용 파라미터 제어, 대역폭 할당 기능등의 연관성을 정의하고 소스 트래픽 특성에 따라 최적의 제어를 수행하기 위한 구조로서 멀티 룰-베이스 트래픽의 특성에 따른 최적의 제어를 수행하기 위한 구조로서 멀티 룰-베이스 구조를 제안한다. 그리고 멀티 룰-베이스 구조에 적합하도록 간단하게 구성된 실시간 가변 윈도우 알고리즘을 제안한다. 컴퓨터 시뮬레이션을 통하여 제안된 하드웨어적인 구성을 가지는 가상 시스템에 온 오프 소스 트래픽을 발생시켜서 제안한 알고리즘의 성능을 분석한다. 그리고 분산 제어의 기능성과 보다 단순화된 시스템의 구현이 가능함을 확인한다.

  • PDF

Movie Box-office Prediction using Deep Learning and Feature Selection : Focusing on Multivariate Time Series

  • Byun, Jun-Hyung;Kim, Ji-Ho;Choi, Young-Jin;Lee, Hong-Chul
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권6호
    • /
    • pp.35-47
    • /
    • 2020
  • 박스 오피스 예측은 영화 이해관계자들에게 중요하다. 따라서 정확한 박스 오피스 예측과 이에 영향을 미치는 주요 변수를 선별하는 것이 필요하다. 본 논문은 영화의 박스 오피스 예측 정확도 향상을 위해 다변량 시계열 데이터 분류와 주요 변수 선택 방법을 제안한다. 연구 방법으로 한국 영화 일별 데이터를 KOBIS와 NAVER에서 수집하였고, 랜덤 포레스트(Random Forest) 방법으로 주요 변수를 선별하였으며, 딥러닝(Deep Learning)으로 다변량 시계열을 예측하였다. 한국의 스크린 쿼터제(Screen Quota) 기준, 딥러닝을 이용하여 영화 개봉 73일째 흥행 예측 정확도를 주요 변수와 전체 변수로 비교하고 통계적으로 유의한지 검정하였다. 딥러닝 모델은 다층 퍼셉트론(Multi-Layer Perceptron), 완전 합성곱 신경망(Fully Convolutional Neural Networks), 잔차 네트워크(Residual Network)로 실험하였다. 결과적으로 주요 변수를 잔차 네트워크에 사용했을 때 예측 정확도가 약 93%로 가장 높았다.

표본 추계학적 동적계획법을 사용한 한강수계 저수지 운영시스템 개발 (Reservoir Operating System Using Sampling Stochastic Dynamic Programming for the Han River Basin)

  • 음형일;박명기
    • 한국수자원학회논문집
    • /
    • 제43권1호
    • /
    • pp.67-79
    • /
    • 2010
  • 한국수자원공사는 낙동강 및 금강수계에 대해 실시간 물관리 시스템을 개발하여 수계 내 다목적 댐의 효율적인 운영을 도모하였다. 본 연구에서는 이를 확장하여 최적화 기법인 표본 추계학적 동적계획법을 사용하여 한강수계 다목적댐의 효율적인 월말 목표저수량을 산정하고 이를 통해 실시간 물관리시스템의 효율을 극대화하고자 수행되었다. 수계 내 댐중 저수용량과 용수공급 측면에서 중요도가 높은 소양강댐, 충주댐, 화천댐 등 3개 댐만을 대상으로 모형을 개발하였으며 저수량 상태변수의 민감도 분석 결과를 통해 저수량 상태변수 개수를 설정하였다. 본 연구를 통해 제시된 최적화모형을 통한 운영률과 한국수자원공사의 운영목표수위에 의한 저수지 운영방식과 비교를 실시한 결과 연평균 37.22 MCM의 수계 내 요구용수 부족량 감소효과와 더불어 발전량 측면에서도 연간 171 GWh가 증가하는 것을 확인하였다. 또한 이수기 저수지 운영계획 시스템을 실제 적용한 결과 2007년~2008년 이수기 동안 전력생산, 수질개선 등을 위한 추가적인 용수공급이 가능하다는 것을 확인하였다. 이러한 실제 적용사례를 통해 SSDP 모형과 이수기 저수지운영 시스템의 그 유용성을 타진할 수 있었으며 다른 수계로 확장을 실시한다면 보다 합리적인 저수지 운영계획이 가능할 것으로 기대한다.