IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험 (Field Test on IEC60364-4-44 for the Application in Korean distribution system)

  • 남기영;최상봉;정성환;이재덕;류희석;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

건축물내 일산화탄소 경보기 설치기준에 관한 연구 (A Study on the Standard for Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2008
  • 최근 5년간 국내 가스사고 중 CO중독사고는 사망 36명, 부상 79명이 발생하였으며, 전체 가스 사고에 비해 인명피해율이 8배나 높게 나타나고 있다. 이러한 CO중독사고의 대부분이 노후 가스보일러 및 다중 가스 사용시설의 배기통 불량에 의한 가스누출사고로 조사되고 있다. 본 연구에서는 실험을 통해 건축물 내 보일러실의 배기통 불량에 의한 CO가스의 누출확산 메커니즘을 해석하였다. 배기통에서 누출된 CO 가스는 건축물 내부의 천정부근에서 가장 높은 농도분포를 보인다. 또한 CO경보기 설치 실험을 통해서 천정부근의 CO경보기가 가장먼저 작동하고, $30{\sim}40$분 경과한 후에 바닥 및 중간에 설치된 경보기가 작동하는 것을 확인하였다. 본 연구를 통해 CO경보기의 적정 설치위치를 확인하였으며, 이 결과를 토대로 건출물내 CO경보기 설치위치를 제안하였다.

  • PDF

접지규정 IEC 60364의 국내 적용을 위한 실증시험장 구축 (Test field for the application of IEC 60364 in Korea)

  • 남기영;최상봉;류희석;이재덕;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.116-118
    • /
    • 2005
  • IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standards deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries defines the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for themselves. The background of circuit of IEC 60364 is based on the ungrounded system as most of European countries adopt. However, since domestic ground system is multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364 and to evaluate the standard is applicable or not to domestic rule for the protection against ground fault through the related test.

  • PDF

EFFECTS OF ATMOSPHERIC WATER AND SURFACE WIND ON PASSIVE MICROWAVE RETRIEVALS OF SEA ICE CONCENTRATION: A SIMULATION STUDY

  • Shin, Dong-Bin;Chiu, Long S.;Clemente-Colon, Pablo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.892-895
    • /
    • 2006
  • The atmospheric effects on the retrieval of sea ice concentration from passive microwave sensors are examined using simulated data typical for the Arctic summer. The simulation includes atmospheric contributions of cloud liquid water and water vapor and surface wind on surface emissivity on the microwave signatures. A plane parallel radiative transfer model is used to compute brightness temperatures at SSM/I frequencies over surfaces that contain open water, first-year (FY) ice and multi-year (MY) ice and their combinations. Synthetic retrievals in this study use the NASA Team (NT) algorithm for the estimation of sea ice concentrations. This study shows that if the satellite sensor’s field of view is filled with only FY ice the retrieval is not much affected by the atmospheric conditions due to the high contrast between emission signals from FY ice surface and the signals from the atmosphere. Pure MY ice concentration is generally underestimated due to the low MY ice surface emissivity that results in the enhancement of emission signals from the atmospheric parameters. Simulation results in marginal ice areas also show that the atmospheric and surface effects tend to degrade the accuracy at low sea ice concentration. FY ice concentration is overestimated and MY ice concentration is underestimated in the presence of atmospheric water and surface wind at low ice concentration. In particular, our results suggest that strong surface wind is more important than atmospheric water in contributing to the retrieval errors of total ice concentrations over marginal ice zones.

  • PDF

도시형 대안학교의 공간구성 및 이용현황 분석 (The Analysis of Spatial Organization and Using Status of Urban Alternative School)

  • 이민선;정진주
    • 교육시설
    • /
    • 제16권4호
    • /
    • pp.61-70
    • /
    • 2009
  • From the mid-1990s, the discussion on alternative schools began in earnest, and with the increasing interests in them, Korean parents' association of alternative education, KPAAE was launched formally in November, 2008. Among the alternative schools in the nation, thirteen urban alternative schools were studied and analyzed. The result indicated that they are being run by individuals and civic organizations with no approval and the facilities and spatial organization of the schools are poor, which is thought to be mainly due to financial reasons as well as the schools' educational goal that puts emphasis on experiences leading to utilize outside local facilities. With this background, the results from the analysis of the facility status and the spatial organization of urban alternative schools led us to understand the followings: First, it showed that per capita average of area of the urban alternative school is approximately 11.995m$^2$, less than 14N, the standard area of institutional schools. Second, depending on the form of facilities, the space of other facilities is shared to make up for insufficient space, and is utilized to a small degree and for multi-purposes. Third, the space reflects the disposition of subject students, and is located in the area with convenient traffic for students' attending the schools conveniently. Fourth, specialized space is run on the basis of educational goals, and the exploring of career and the improving of sociality are pursued through internship programs associated with local facilities. Thus, it is desirable for the minimum per capita area of the urban alternative school to meet 14N, the standard area of the institutional schools in order that the urban alternative school may overcome the spatial limitation and the financial hardship stemming from the practically difficult constructing of new buildings and the small scale operation, and it may make flexible use of the space, and the students may live their lives smoothly. Also, it is thought that for the activating of the urban alternative schools, the plans for utilizing various facilities associated with local facilities should be considered.

IoT 기반 실내 공기질 모니터링 시스템 (Indoor Air Quality Monitoring Systems in the IoT Environment)

  • 오창세;서민석;이정혁;김상현;김영돈;박현주
    • 한국통신학회논문지
    • /
    • 제40권5호
    • /
    • pp.886-891
    • /
    • 2015
  • 최근 전 세계적으로 인류의 건강을 위협하는 요소로 대기오염이 대두되고 있는 가운데 세계보건기구(WHO : World Health Organization)의 발표에 의하면 대기오염으로 인해 사람의 건강을 해친다고 발표했으며, 서울시의 '2011~2014년 7월 다중이용시설 실내 공기 질 측정 결과'에 의하면 대부분의 다중이용시설에서 실내공기오염도 기준을 위반한 것으로 조사되었다. 이러한 실내에서 발생하는 대기오염은 폐 질환, 천식, 기관지염 등의 질병을 유발하며 본 논문에서는 이와 관련하여 환경센서를 이용하여 실내공기질을 측정하고, 측정된 데이터를 분석하여 환기 개선에 필요한 액츄에이터 신호를 생성하고 실시간으로 실내 공기 질 측정 모니터링 시스템을 구현하여, 우리 생활에서 대기오염을 자율적으로 관리할 수 있도록 한다.

폐CNT와 전도촉진재를 혼입한 시멘트 모르타르 블록의 발열 전도 특성 (Heating Transferring Charcteristics of Cement Mortar Block with Waste CNT and Conduction Activator)

  • 구현철;김운학;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제10권2호
    • /
    • pp.176-183
    • /
    • 2022
  • 저전력 사용이 가능한 발열콘크리트를 제작하기 위하여 시멘트 모르타르에 고순도 폐CNT를 혼입하였으며, 모르타르의 전도율을 향상시키기 위하여 압축강도를 제어하는 수준에서 탄소섬유와 폐음극재를 활용하고자 하였다. 사용된 폐CNT는 다중벽 CNT의 함유량이 많은 것으로 분석되었고, 모르타르 배합시 분산성을 높이기 위하여 액상형으로 치환하여 사용하였다. 모르타르 발열시 태양광 등에 의한 소형 자가발전 설비를 활용하고 전자파를 최소화하기 위하여 DC 24 V이하의 전력 사용시의 모르타르의 온도 변화를 평가하였다. 액상형 폐CNT를 적용하고, DC 24 V의 전압을 도입한 경우 200 × 100 × 50 mm 블럭 시험편에서 60 ℃까지 상승하였으며, 액상형 폐CNT와 탄소섬유, 폐음극재를 모두 사용한 경우에는 DC 12 V에서도 55 ℃이상까지 온도가 상승하여 현장 적용성이 충분한 것으로 판단되었다. 특히 발열에너지 변화량에 있어서도 다른 변수들과 비교하여 효과적인 것으로 나타났다.

A Study of the Evacuation Safety for Workers on the Theater Stage Plan Shapes

  • Yong-Gyu, Park;Heung-Sik, Woo
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권3호
    • /
    • pp.149-157
    • /
    • 2023
  • 본 연구는 공연시설 내 공연장 무대공간에서 위기상황에서 피난 시 공연예술종사자가 반입구 및 공연자통로를 적극적으로 활용하는 것을 제안하는 것이 목적이다. 먼저 공연장 안전과 관련된 제도를 분석하고 무대피난 유형을 건축법 내 객석 피난 기준을 적용하여 A, B, C, D 형태로 분류하였다. 둘째, 측정자료를 바탕으로 통계자료를 정리하고 각 형태의 특징을 정리하였다. 셋째, 무대공간에서 피난 경로의 피난 안전성을 평가하기 위해 네트워크 신뢰도 측정방법을 차용하였다. 그리고 무대중심에서 반입구 방향, 공연자 출입문 방향이 피난에 유리함을 정량적으로 확인하였다. 본 연구에서 피난형태에 따른 피난의 유리함(A(0.1274)>B(0.1228)>C(0.0487))을 구분할 수 있었다. 이러한 결과는 무대피난 안전성을 향상과 무대피난의 기초자료로 활용될 수 있기를 기대한다.

드론 기반 스마트 방재 방안 연구 (Drone-based smart quarantine performance research)

  • 유순덕
    • 문화기술의 융합
    • /
    • 제6권2호
    • /
    • pp.437-447
    • /
    • 2020
  • 본 연구의 목적은 드론 기반 스마트 방역 연구로서 드론을 방재 분야에 활용을 통한 대응방안과 기대효과를 연구하는 것이다. 현행 방재업무의 문제점에 대한 검토와 이에 따른 대응안을 환경적, 시장적, 기술적 접근으로 살펴보면 다음과 같다. 첫째로 환경적 측면에서 드론 기반 관제를 활용한 방재업무의 활용 효과는 산림, 조류인플루엔자, 가축, 시설지역, 모기 유충, 해충 등 광범위한 활용과 AI 및 콜레라 등 각종 방역업무 단순화 및 효과적 방역체계 제공 할 수 있다. 둘째, 시장적 측면에서 방역방법의 신기술 도입을 통한 국내 표준화 드론을 활용한 소독방역 임무 활용에 따른 축산·가축 방역 관련 법령, 행정규칙의 기준마련, 관련 산업의 동반성장과 신시장 발굴, 가축 질병 방역에 투입되는 연간 예산 절감의 효과를 가져온다. 셋째, 기술적 측면은 (1) 새로운 가축 질병 방역형태인 다중드론 활용 소독 방역의 현장적용, (2) 드론 산업 소프트웨어 분야의 혁신, (3) 다양한 시장에 적용 가능한 드론 관제/제어 통합시스템으로 산업 다변화, (4) 빅데이터 드론 이동로 3차원 공간정보 분석 정밀 드론 교통정보제공으로 안전성 높은 비행 보장, (5) 다수의 드론 동시 자동 임무 비행이 가능하여 저비용 고효율 시스템 보급 실현, (6) 고도의 정밀 비행기술 불필요에 따른 분야별 드론 이용자 증가로 고찰되었다. 본 연구는 문헌 조사와 전문가의 의견을 기반으로 작성되어 향후 연구 분야는 드론 기반 서비스에 대한 실증적 자료를 기반으로 그 효과에 대해 입증하는 작업이 필요하다. 본 연구의 기대효과는 드론을 방재업무에 적극적 활용 지원 또는 이와 관련된 정책을 수립하는데 이바지 한다.

스마트 그린시티 개념을 적용한 고층주거단지 계획기법에 관한 연구 : 행정중심복합도시 2-1생활권을 중심으로 (A Study on the Planning Technique of High-rised Housing Estates Applying Smart Green City Concept : Focus on Multi-functional Administrative City 2-1 Neighborhood)

  • 이서정;이응현;오덕성
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.379-387
    • /
    • 2016
  • 본 연구는 스마트 그린시티로 전환을 위한 설계 및 건설 측면과 지원시스템 측면의 통합적 계획의 필요성을 인식하고 고층주거단지를 대상으로 공간위계별로 적용 가능한 계획기법과 적용실태를 파악하고자 한다. 이를 위한 연구의 방법은 다음과 같다. 첫째, 문헌 및 선행연구 고찰을 통하여 스마트 그린시티의 개념을 정립하고 3개 공간 위계, 7개 기본방향, 17개 주요특성으로 분류된 고층주거단지 계획체계를 설정한다. 둘째, 선행연구 검토와 전문가 FGI를 통해 스마트 그린시티 개념을 적용한 고층주거단지 설계 및 건설 측면의 계획기법 28개와 스마트 시스템 측면의 계획기법 28개를 도출한다. 셋째, 행정중심복합도시 2-1생활권 4개 고층주거단지 계획안을 대상으로 계획기법의 적용실태를 분석한다. 연구의 결과 스마트 그린시티 개념을 적용한 고충주거단지 계획의 주요특성 중 '교통네트워크 연계', '친환경 단지배치', '녹색교통 활성화', '신재생에너지 효율적 활용', '범죄 및 재해 안전 성능', '고성능 고효율 설비 활용'에 해당하는 계획기법이 사례에서 적극적으로 적용되었음을 확인하였다. 또한 고층주거단지 계획 시 공간 위계별로 설계 및 건설 계획기법과 스마트 시스템 계획기법 적용의 시사점을 확인할 수 있었다.