• Title/Summary/Keyword: Multi-tier system

Search Result 64, Processing Time 0.026 seconds

Adaptational changes of behaviors in hens introduced to a multi-tier system

  • Cheon, Si Nae;Choi, Yang-Ho;Park, Kyu-Hyun;Lee, Jun Yeob;Jeon, Jung Hwan
    • Journal of Animal Science and Technology
    • /
    • v.62 no.2
    • /
    • pp.276-291
    • /
    • 2020
  • This study was conducted to investigate behavioral changes in laying hens (Hy-Line Brown) after transfer to a multi-tier system from the floor system and to examine their production performance. The hens were randomly divided into two groups and were allocated to the multi-tier system and the floor system at a commercial farm. Behavior of the laying hens was recorded by CCD (charge-coupled device) cameras and a digital video recorder. The data were scanned every 2 min to obtain an instantaneous behavioral sample or were immediately counted whenever the hens exhibited a designated behavior. Behavior changed dramatically during the first seven days. Egg production was higher in the multi-tier system, while cracked and dirty eggs were more frequent in the floor system (p < 0.05). No differences in mortality rate or egg quality were observed between the groups. In conclusion, the hens needed at least seven days to adapt to the multi-tier system. The multi-tier system was more efficient than the floor system in terms of production performance.

Development of Management Information System Based on Distributed Object Middleware (분산 객체 미들웨어 기반의 경영정보시스템 개발)

  • Gwon, Yeong-Do;Jo, Yu-Seop
    • 연구논문집
    • /
    • s.28
    • /
    • pp.239-246
    • /
    • 1998
  • Today’s information technology departments face a dilemma to create a competitive advantage for the organization by developing. deploying, and managing distributed applications that scale across the LAN, WAN, and Internet, while preserving investments in systems. Applications, information. IT organizations are today being asked to build the future, without breaking systems that maintain the current business. A possible answer to this dilemma is the implementation of a multi-tier distributed computing architecture. Multi-tier architecture has the potential to provide better, more timely information across the enterprise at a lower cost than the current combination of PC LAN, two-tier client/server, or mainframe applications that have been developed in most organizations. In this paper, we implement management information system based on distributed object middleware using multi-tier distributed computing architecture. This system uses Microsoft's implementation of DCOM/ActiveX and provides easily accessible web interface to the system users.

  • PDF

A Case Study for Improving Performance of A Banking System Using Load Test (부하테스트를 이용한 금융 시스템의 성능개선 사례)

  • Kim, Tai Suk;Lee, Jong Yun;Kim, Jong Soo
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.12
    • /
    • pp.1501-1508
    • /
    • 2015
  • In this paper, we describe a case study to improve performance through the load testing of multi-tired system for financial accounts before the system opening. The load test was conducted after the data collection tools(Performance Monitor, DB PSSDiag) were installed. By analyzing the collected log, we were able to identify the main sector requiring performance improvements among the presentation tier, web tier, business logic tier and data tier. The ASP.NET server-down on the web tier could be improved by modifying the parameter values in the configuration file. Some server downs occurred on the business logic tier when a large number of users access at the same time, were more difficult to be solved. By analyzing the hang-dump at the server-down time, we were able to find a process that caused the problem. and we had to modify the relevant codes. For major performance improvements of the data-tier, indices of some queries was optimized by using the built-in DBMS query analyzer, after analyzing the log of long-response-time queries. The problems and solutions considered in this case study will be a reference for the performance improvement of a multi-layer system with the similar structure.

An Implementation of the Avatar Chatting System for Network-Based Multi-User Environment (네트워크 기반 다자간 아바타 채팅 시스템의 구현)

  • 김종수;권오준;김태석
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.171-174
    • /
    • 2003
  • 다자간 채팅은 인터넷 기반에서 진보적인 발전을 한 분야이고, 네트워크 게임과 같은 어플리케이션 제작에 있어 필수적인 기술이다. 본 논문에서는 자바 기술을 이용하여 one-tier, two-tier 구조가 가진 불편한 유지보수, 데이터 은닉의 문제점을 해결하기 위하여 multi-tier architecture로 아바타를 사용하여 다자간 채팅시스템을 구현하였다. 또한 채팅에서 흥미를 유발하기 위한 캐릭터 전송기술, 다양한 문자를 보내기 위한 문자 포맷 기술을 구현하였다.

  • PDF

Response Time Simulation for 2-tier and 3-tier C/S System (2-계층과 3-계층 C/S 시스템의 응답시간 시뮬레이션)

  • Kim Yong-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.3
    • /
    • pp.45-53
    • /
    • 2004
  • The fact that the end-user response time could become unacceptable in the 2-tier C/S system has been well known to C/S system developers. But inexperienced new developers who want to provide mobile solutions using PDA sometimes do not realize the ominous consequences of the 2-tier C/S systems. Except for the easy of development. the 2-tier C/S system has many weak points like in application deployment, security, scalability, application reuse, heterogeneous DBMS support, availability. and response time. This paper analyzes the response time in the 2-tier and 3-tier C/S systems through simulation. Although the problem space is confined to the 2 and 3 tiers, the result could be equally applied to any multi-tier systems.

  • PDF

Development of Wireless Monitoring System for Layers Rearing in Multi-tier Layers Battery by Machine Vision (기계시각을 이용한 고단 직립식 산란계 케이지의 무선 감시시스템 개발)

  • Lim, Song-Su;Chang, Dong-Il;Lee, Seung-Joo;So, Jae-Kwang
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.173-178
    • /
    • 2007
  • This research was conducted to develop and analyze a wireless monitoring system for judging if sick or dead layers (SDL) exist in multi-tier layers battery (MLB) by machine vision, and to evaluate the performance between a wired monitoring system and it. This study used the AP (Access Point), the RS-285 to RS-232 converter, RS-232 to Ethernet converter, PICBASIC board and upgraded lump image processing method to change wired monitoring system into wireless monitoring system. The system was tested at a pilot farm and farm layer house. Results showed that monitoring judgement success rate at a pilot farm on normal cage (without SDL) was 82.3% and that on abnormal cage (with SDL) was 87.5%, respectively. And communication performance test results showed at farm layer house was $700{\sim}900$ kbps while equipments operated. There were dropped slightly than performance of wired monitoring system, however, the quantity was too small to make a significant difference of performance of the controling system developed for wireless communication.

A Risk-based System Analysis Model for Improving the Performance of Financial Solutions

  • Lee, Jong Yun;Kim, Jong Soo;Kim, Tai Suk
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.11
    • /
    • pp.1367-1374
    • /
    • 2015
  • In this paper, we propose a model which can prioritize the performance improvement work by analyzing the major risks and their influence, which can cause performance degradation in the system and show an example of a performance improvement using this model. In presentation-tier, as a result of log data analysis before and after the performance improvement of key processes which handle financial transactions, this model brought the CPU utilization and memory enhancement in the performance improvement work of the financial system which was carried out by applying the proposed model. It has been confirmed that the entire end-user can be accommodated. In the web-tier, the available memory increased by 200MB and we were able to improve the server restart(Recycling) that was sustained in the existing system. In the business logic-tier, we have been able to see better figures after performance improvements through the graph which analyzes the log collected with the key performance counters such as CPU%, Batch Requests/sec. In the data-tier, it has been confirmed that CPU usage and standby operation were reduced and the throughput was found to increase.

A Design of Multi-tier e-Learning System (다계층 e-러닝 시스템의 설계)

  • 고일석;나윤지
    • Proceedings of the Korea Information Assurance Society Conference
    • /
    • 2004.05a
    • /
    • pp.97-101
    • /
    • 2004
  • In this study, we designed A multi-tier e-learning system using hybrid multimedia method, The proposal system can provide an interaction and adaptability of a web-based system and high quality multimedia services of an off-line-based system. The proposal system improved quality of a multimedia, a user's convenience, adaptability and an interaction on e-learning system.

  • PDF

Development of Wired Monitoring System for Layers Rearing in Muti-tier Layers Battery by Machine Vision (기계시각을 이용한 고단 직립식 산란계 케이지의 유선 감시시스템 개발)

  • Zheng, S.Y.;Chang, D.I.;Lee, S.J.;So, J.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.436-442
    • /
    • 2006
  • This research was conducted to design and develop a wired monitoring system for judging if sick or dead layers (SDL) exist in multi-tier layers battery (MLB) by machine vision, and to analyze its performance. In this study, 20 Brown Leghorn (Hi-Brown) layers aged 37 weeks old, were used as the experimental animals. The intensity of concern paid by layers on feed was over 90% during 5 minutes and 30 seconds after providing feed, and normal layers (NL) had been standing to take feed for that period. Therefore, in this study, the optimal judging time was set by this test result. The wired monitoring system developed was consisted of a driving device for carrying machine vision systems, a control program, a RS232 to RS485 convertor, an automatic positioning system, and an image capture system. An image processing algorithm was developed to find SDL in MLB by the processes of binary processing, erosion, expansion, labeling, and reckoning central coordinate of the captured images. The optimal velocity for driving unit was set up as 0.13 m/s by the test results for wired monitoring system, and the proximity switch was controlled not to be operated for 1.0 second after first image captured. The wired monitoring system developed was tested to evaluate the remote monitoring performance at lab-scale laying hen house. Results showed that its judgement success.ate on normal cage (without SDL) was 87% and that on abnormal cage (with SDL) was 90%, respectively. Therefore, it would be concluded that the wired monitoring system developed in this study was well suited to the purpose of this study.