• 제목/요약/키워드: Multi-support excitation shaking table

검색결과 3건 처리시간 0.018초

내진실험 연구를 위한 다지점 가진 지동대의 활용 (Applications of Seismic Test using Multi-platform Shaking Table System)

  • 최형석;김남식;정진환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.126-131
    • /
    • 2013
  • As the testing instrument for seismic research, the multi-platform shaking table system of SESTEC in the Pusan National University was introduced to suggest the multi-support shaking table testing methods and also to investigate its ability and applicability. 2 spans single-pylon cable-stayed bridge model, 3 spans girder bridge model and nuclear piping system model are presented and the acceleration and displacement table feedbacks of the each tests are compared to verify the simultaneous excitation ability in time domain and frequency domain.

  • PDF

지진격리 강재 케이블 교량의 다지점 진동대 실험 (Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge)

  • 김성도;안진희;공영이;최형석;정진환
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.161-171
    • /
    • 2015
  • A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.

지진에 의한 원전 보조건물 전단벽의동적 응답 특성 추정 (Seismic Response Characterization of Shear Wall in Auxiliary Building of Nuclear Power Plant)

  • 모터 라만;타미나 나하르;백건휘;김두기
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.93-102
    • /
    • 2021
  • The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.