  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

PET/CT 장치의 uniformitly측정에 관한 연구 (A Study of Uniformity Test in PET/CT)

  • 김수근;정희일;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권1호
    • /
    • pp.13-19
    • /
    • 2006
  • PET scanner는 양전자의 소멸복사에 의한 511 Kev의 감마선을 검출한다. multi ring detector에서 선원과 검출기사이의 기하학적 위치에 따른 감마선 검출에 대한 균등성(uniformity)을 검토 분석하였다. 감마선원과 검출기의 배열위치에 따른 이론적 검토와 일정한 크기의 phantom 내에서 방출되는 감마선을 2차원적으로 preset count하고, 검출기의 위치에 따라 평균계수치에 대한 편차율의 분포를 통하여 그 균등성을 비교 분석하였다. 1 bed data를 얻을 수 있는 47개의 검출기군으로 분류하고, 각 검출기군의 위치에 따른 편차율을 비교분석한 결과, 산란선과 산란되지 않은 모든 방사선량의 분포가 많은 중심군인 3번째부터 45번째까지에서는 평균편차의 비율이 $0.1{\sim}0.7%$로 비교적 균등도가 높게 나타났으나, 주변부에서는 편차율의 분포가 $1.1{\sim}5.2%$의 차이를 나타내고 있어, 주변부에서의 균등성이 중심부보다 감소되었다. 이것은 검출기 위치에 따른 계수율의 차이에 대한 이론적 근거와 일치하고 있으며, 감도를 알기위한 계수측정 부분에서도 중심부와 주변부와의 차이가 크게 다르게 나타났다. 이와같은 불균등성을 감소시키기 위하여 선원으로부터 모든 검출기 유효시야(UFOV) 내에서 충분한 방사능이 검출될 수 있도록 하는 우선적 조치가 필요하다고 판단된다.

  • PDF