• Title/Summary/Keyword: Multi-point measurement

Search Result 182, Processing Time 0.024 seconds

Development of the Noise Prediction Program to apply in Construction Site (현장 적용성을 향상시킨 건설현장 소음예측프로그램 개발)

  • Oh, Jin-Kyun;Park, Hye-Na;Sohn, Jang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.409-417
    • /
    • 2009
  • Nowadays, the construction sites are growing in city every year, so complaints for construction noise have increased more and more. To analyze this noise scientifically, construction noise prediction program was developed in 1998 and 2005 but it is too difficult to apply program in field because there is few soundproof facilities and it can't understand the coordinate system and so on. The aim of this study is to develop noise prediction program to apply in construction sites. For this, the problems of existing program was analyzed and survey was performed to get requestion of field overseer and upgraded program. To get reliability of program, it was compared with sound measurement value in field. As a result, construction sound prediction program have various soundproof facilities data than existing program. It can also analyze multi receiver point at the same time for several construction machinery. Most of all, it is more powerful to set receiver or source in the axis of X, Y, Z. so program user can make use of it easily. An average of difference is -0.9~1.8 dB.

Aerodynamic Heating Analysis of Spike-Nosed Missile (스파이크가 부착된 유도탄의 공력 가열 해석)

  • Jung Suk Young;Yoon Sung Joon;Byon Woosik;Ahn Chang Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.3 s.18
    • /
    • pp.21-29
    • /
    • 2004
  • Numerical analysis of aerodynamic heating for KPSAM is performed using aerodynamic heating model suitable to KPSAM, which has complex flow field resulting from the spike attached to the dome, such as large separation area and the strong shock/boundary layer interaction region around reattachment point on the dome. The aerodynamic heating model is validated and modified through the comparison between the flight test measurement and the thermal analysis results. TFD temperature sensors are installed on the dome to measure surface temperature during the flight. Computation results, obtained from the heat transfer analysis on the sensors, agree well with flight test data. The aerodynamic heating model provides heat transfer rate into surface as a boundary condition of unsteady 1D/axisymmetric thermal analysis on the missile structure. The axisymmetric thermal analysis using FLUENT is more versatile than the 1D analysis and can be applied to the heating problem related with complex structures and multi-dimensional heat transfer problems such as prediction of temperature rise at contact surface of different materials.

Multi-facet 3D Scanner Based on Stripe Laser Light Image (선형 레이저 광 영상기반 다면 3 차원 스캐너)

  • Ko, Young-Jun;Yi, Soo-Yeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.10
    • /
    • pp.811-816
    • /
    • 2016
  • In light of recently developed 3D printers for rapid prototyping, there is increasing attention on the 3D scanner as a 3D data acquisition system for an existing object. This paper presents a prototypical 3D scanner based on a striped laser light image. In order to solve the problem of shadowy areas, the proposed 3D scanner has two cameras with one laser light source. By using a horizontal rotation table and a rotational arm rotating about the latitudinal axis, the scanner is able to scan in all directions. To remove an additional optical filter for laser light pixel extraction of an image, we have adopted a differential image method with laser light modulation. Experimental results show that the scanner's 3D data acquisition performance exhibited less than 0.2 mm of measurement error. Therefore, this scanner has proven that it is possible to reconstruct an object's 3D surface from point cloud data using a 3D scanner, enabling reproduction of the object using a commercially available 3D printer.

Fiber-optic macro-bending sensor aided by metal capillary (매크로 벤딩 측정을 위한 금속 모세관 결합 광섬유 센서)

  • 백승인;정윤찬;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.289-293
    • /
    • 2001
  • A metal capillary splice fiber-optic sensor was fabricated for use as an intensity-based macro-bending sensor. As the radius of curvature due to the macro-bending decreases, the angular misalignment of the fiber ends inside the metal capillary increases, i.e., the coupling efficiency of the fiber splice is reduced. Thus, macro-bending can be detected by the measurement of the reduction of transmitted power. The detectable range of macro-bending. was measured approximately from 20 mm to 85 mm. The center wavelengths of the fiber Bragg gratings are 1543.3 nm and 1549.5 nm, respectively. The maximum bending loss of this sensor was measured about -11.92 dB. Using this metal capillary spliced fiber sensor and fiber Bragg gratings, macro-bending detection has been demonstrated, and it is shown to have potential for multi-point macro-bending sensors. nsors.

  • PDF

Improved Georeferencing of a Wearable Indoor Mapping System Using NDT and Sensor Integration

  • Do, Linh Giang;Kim, Changjae;Kim, Han Sae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.5
    • /
    • pp.425-433
    • /
    • 2020
  • Three-dimensional data has been used for different applications such as robotics, building reconstruction, and so on. 3D data can be generated from an optical camera or a laser scanner. Especially, a wearable multi-sensor system including the above-mentioned sensors is an optimized structure that can overcome the drawbacks of each sensor. After finding the geometric relationships between sensors, georeferencing of the datasets acquired from the moving system, should be carried out. Especially, in an indoor environment, error propagation always causes problem in the georeferencing process. To improve the accuracy of this process, other sources of data were used to combine with LiDAR (Light Detection and Ranging) data, and various registration methods were also tested to find the most suitable way. More specifically, this paper proposed a new process of NDT (Normal Distribution Transform) to register the LiDAR point cloud, with additional information from other sensors. For real experiment, a wearable mapping system was used to acquire datasets in an indoor environment. The results showed that applying the new process of NDT and combining LiDAR data with IMU (Inertial Measurement Unit) information achieved the best result with the RMSE 0.063 m.

Sensitivity Analysis of Long Baseline System with Three Transponders (세 개의 트랜스폰더로 이루어진 장기선 위치추적장치의 민감도 해석)

  • Kim, Sea-Moon;Lee, Pan-Mook;Lee, Chong-Moo;Lim, Yong-Kon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.27-31
    • /
    • 2003
  • Underwater acoustic navigation systems are classified into three systems: ultra-short baseline (USBL), short baseline (SBL), and long baseline (LBL). Because the USBL system estimates the angle of a submersible, the estimation error becomes large if the submersible is far from the USBL transducer array mounted under a support vessel. SBL and LBL systems estimate submersible's location more accurately because they have wider distribution of measuring sensors. Especially LBL systems are widely used as a navigation system for deep ocean applications. Although it is most accurate system it still has estimation errors because of noise, measurement error, refraction and multi-path of acoustic signal, or wrong information of the distributed transponders. In this paper the estimation error of the LBL system are analyzed from a point of sensitivity. It is assumed that the error exists only in the distance between a submersible and the transponders. For this purpose sensitivity of the estimated position with respect to relative distances between them is analyzed. The result says that estimation error is small if the submersible is close to transponders but not near the ocean bottom.

  • PDF

An Experimental Study for the Real Scale Impulse Measurement Setup of Overhead Distribution Lines (22.9kV 가공배전선로의 뇌 과전압 실규모 측정시스템)

  • Ryoo Hee Suk;Jung Dong Hak;Nam Ki Young;Lee Jae Duck;Kim Dae Kyung;Park Sang Man;Jeong Young Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.375-377
    • /
    • 2004
  • 22.9kV급 가공배전선에서의 뇌격현상은 직접측정이 어렵기 때문에 지금까지 절연협조수준의 도출은 수치적인 모의해석과정에서 얻어진 과전압강도를 근거로 하고 있다. 대표적인 모델에 대해서 만이라도 실측자료를 확보할 수 있다면 해석과정의 정확도를 높이는 중요한 전기가 될 수 있다. 이러한 가공배전선로의 뇌격현상을 측정하기 위한 상용설비를 이용한 경제적 측정시스템을 구성하였다. 접지회로에서 발생하는 과전압으로 인한 인명뿐 아니라 계측설비의 안전성도 확보하고 과 경제성확보를 위하여 전주 중간에 장시간용 UPS 및 파형측정설비를 2중 차폐함 안에 넣어 1점 접지상태가 되도록 고정하고 측정point에 HV divider 및 로고스키코일을 설치하여 한 지점에서의 측정회로를 구성하였다. 전체적으로 뇌격전류 주입 위치에서부터 3지점을 선정하여 측정설비를 설치하고 경제적인 Rs485 multi-drop 회로를 구성하여 통신망을 확보하였다. 직렬통신망에는 뇌격시험 시 발생하는 과전압에 대한 보호회로로서 간단한 수동식 개폐회로를 구성하였다. 측정파형을 전체적으로 전송받는 속도가 약간 늦기는 하나 간단한 data acquisition program을 사용하여 전체 측정회로를 가동시킬 수 있었다.

  • PDF

Earth Analysis Method for Installation of Equipment for Moving Pesticide Spraying System (농약살포시스템 이동을 위한 기구물 설치를 위한 대지 분석방법)

  • Boo, Chang-Jin
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1152-1157
    • /
    • 2018
  • In this paper, we try to solve the difficulties of the location of the structure for the movement of the wire - based pesticide spraying equipment designed for field farming. To do this, we apply earth resistivity measurement method and analysis technique which can indirectly grasp the earth structure. Electrodes are installed on the field in a selected farming area, and multi-switches built in the control board are driven to automatically acquire ground resistivity data. Then, the optimal point suitable for the actual structure installation is selected through the site analysis using the 2D image restoration algorithm.

Synthesis, Characterization and in vitro Antibacterial Studies on Mixed Ligand Complexes of Iron(III) Based on 1,10-phenanthroline

  • Tigineh, Getinet Tamiru;Sitotaw, Getu;Workie, Amogne;Abebe, Atakilt
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.3
    • /
    • pp.203-208
    • /
    • 2021
  • As part of our attempt to discover novel active compounds against multi-drug resistant pathogens, we hereby report two new complexes of iron(III) with formulae: [Fe(L1)2(H2O)2]Cl3 and [Fe(L1)2(L2)(H2O)]Cl2 where L1 = 1,10-phenanthroline (C12H8N2) and L2 = guanide (C5H4N5O-). The synthesized complexes were characterized using spectroscopic analysis (ESI-MS, ICP-OES, FT-IR, and UV-Vis), cyclic voltammetry, CHN analysis, gravimetric chloride determination, melting point determination, and conductance measurement. Octahedral geometries are assigned to both complexes. In vitro antibacterial activity was tested on two Gram-positive (Staphylococcus aureus, Streptococcus epidermidis) and two Gram-negative (Escherichia coli and Klebsiella pneumoniae) bacteria using the disc diffusion method. The complexes demonstrated appreciable activity against these pathogens. Interestingly, the [Fe(L1)2(L2)(H2O)]Cl2 complex manifested a higher degree of inhibition against the drug-resistant Gram-negative bacteria than the commercially available drug, namely erythromycin.

The Comparision of X-ray Detection Characteristics as Additive ratio of As in a-Se of $BrO_2/a-Se$ Film ($BrO_2/a-Se$ 필름의 a-Se에 첨가된 As 변화에 따른 X선 검출특성 비교)

  • Park, Ji-Koon;Choi, Jang-Yong;Kim, Dae-Hwan;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.424-427
    • /
    • 2002
  • In this papaer, there is a basic research for the development of the Hybrid digital radiation detector with a new system, make up for existing digital radiation detector of direct/indirect method with a weak point. for enhance the efficiency characteristics of signal response from X-ray detector using the a-Se, We make sample with various kinds of layer, through the ratio of As(0.l%,0.3%,0.5%,1%,1.5%,5%,10%). We measure net charge with a leakage current and photo current for electric charateristics. Ratio of As in a-Se consist of 7 stage, It made of using the thermal deposition system, In the made of samples, we made multi layer using the EFIRON optical adhesives from phosphor layer consist of Oxybromide$(BrO_2)$. As a result of X-ray measurement, the best result is ; leakage current(0.30nA/cm2), net charge(610.13pC/cm2/mR) when the condition is voltage(9V/um), 0.3% ratio of As in multi layer(BrO2 + a-Se)

  • PDF