• Title/Summary/Keyword: Multi-point measurement

Search Result 182, Processing Time 0.027 seconds

Multi-point displacement monitoring of bridges using a vision-based approach

  • Ye, X.W.;Yi, Ting-Hua;Dong, C.Z.;Liu, T.;Bai, H.
    • Wind and Structures
    • /
    • v.20 no.2
    • /
    • pp.315-326
    • /
    • 2015
  • To overcome the drawbacks of the traditional contact-type sensor for structural displacement measurement, the vision-based technology with the aid of the digital image processing algorithm has received increasing concerns from the community of structural health monitoring (SHM). The advanced vision-based system has been widely used to measure the structural displacement of civil engineering structures due to its overwhelming merits of non-contact, long-distance, and high-resolution. However, seldom currently-available vision-based systems are capable of realizing the synchronous structural displacement measurement for multiple points on the investigated structure. In this paper, the method for vision-based multi-point structural displacement measurement is presented. A series of moving loading experiments on a scale arch bridge model are carried out to validate the accuracy and reliability of the vision-based system for multi-point structural displacement measurement. The structural displacements of five points on the bridge deck are measured by the vision-based system and compared with those obtained by the linear variable differential transformer (LVDT). The comparative study demonstrates that the vision-based system is deemed to be an effective and reliable means for multi-point structural displacement measurement.

Development of Multi-point Heat Flux Measurement for Steel Quenching (강재 열처리용 다점 열유속 측정 기술 개발)

  • Lee, Jungho;Oh, Dong-Wook;Do, Kyu Hyung;Kim, Tae Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.4
    • /
    • pp.181-189
    • /
    • 2012
  • The demand on quantitative measurement of the heat flux is motivated in making higher-quality steel product through a water quenching process of plate mill. To improve a spatial degree of heat flux measurement, the multi-point heat flux measurement was carried out by a unique experimental technique that has a combination of the existing single-point heat flux gauge. The corresponding heat flux can be easily determined by Fourier's law in a conventional way. The multi-point heat flux gauge developed in this study can be applicable to measure the surface heat flux, the surface heat transfer coefficient during a water quenching applications of steelmaking process. The results exhibit different heat transfer regimes; such as single-phase forced convection, nucleate boiling, and film boiling, that are occurred in close proximity on the multi-point heat flux gauge quenched by water impinging jet.

Displacement Measurement of Multi-point Using a Pattern Recognition from Video Signal (영상 신호에서 패턴인식을 이용한 다중 포인트 변위측정)

  • Jeon, Hyeong-Seop;Choi, Young-Chul;Park, Jong-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1256-1261
    • /
    • 2008
  • This paper proposes a way to measure the displacement of a multi-point by using a pattern recognition from video signal. Generally in measuring displacement, gab sensor, which is a displacement sensor, is used. However, it is difficult to measure displacement by using a common sensor in places where it is unsuitable to attach a sensor, such as high-temperature areas or radioactive places. In this kind of places, non-contact methods should be used to measure displacement and in this study, images of CCD camera were used. When multi-point is measure by using a pattern recognition, it is possible to measure displacement with a non-contact method. It is simple to install and multi-point displacement measuring device so that it is advantageous to solve problems of spatial constraints.

Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes (다점 피토관을 이용한 기체 유량 측정의 불확도 평가)

  • Yang, Inyoung;Lee, Bo-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.

A Study on Three-Dimensional Motion Tracking Technique for Floating Structures Using Digital Image Processing (디지털 화상처리를 이용한 부유식 구조물의 3차원운동 계측법에 관한 연구)

  • Jo, Hyo-Je;Do, Deok-Hui
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.2 s.28
    • /
    • pp.121-129
    • /
    • 1998
  • A quantitative non-contact multi-point measurement system is proposed to the measurement of three-dimensional movement of floating vessels by using digital image processing. The instantaneous three-dimensional movement of a floating structure which is floating in a small water tank is measured by this system and its three-dimensional movement is reconstructed by the measurement results. The validity of this system is verified by position identification for spatially distributed known positional values of basic landmarks set for the camera calibration. It is expected that this system is applicable to the non-contact measurement for an unsteady physical phenomenon especially for the measurement of three-dimensional movement of floating vessels in the laboratory model test.

  • PDF

Displacement Measurement of Multi-Point Using a Pattern Recognition from Video Signal (영상 신호에서 패턴인식을 이용한 다중 포인트 변위측정)

  • Jeon, Hyeong-Seop;Choi, Young-Chul;Park, Jong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.675-680
    • /
    • 2008
  • This paper proposes a way to measure the displacement of a multi-point by using a pattern recognition from video signal. Generally in measuring displacement, gab sensor, which is a displacement sensor, is used. However, it is difficult to measure displacement by using a common sensor in places where it is unsuitable to attach a sensor, such as high-temperature areas or radioactive places. In this kind of places, non-contact methods should be used to measure displacement and in this study, images of CCD camera were used. When displacement is measure by using camera images, it is possible to measure displacement with a non-contact method. It is simple to install and multi-point displacement measuring device so that it is advantageous to solve problems of spatial constraints.

  • PDF

A Study on the Characteristics of Multi-point Pilot Tube Flow-meter (다점 피토관 유량계의 특성에 관한 연구)

  • 임재명;윤복현;박경암
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.2 s.11
    • /
    • pp.35-43
    • /
    • 2001
  • The flow characteristics passing a multi-point Pitot tube flow-meter of diamond shape and the characteristics of flow coefficients of the flow-meter are experimentally studied by varying combination of upstream rectangular dual elbows. The results provide the flow coefficients, which show good stability and reliability within the Reynolds number range coveted here in this study, and which can be used to measure flow-rates in practice. The variation of dual elbows upstream can change the velocity field so much that the flow pattern might thwart the precise flow measurement using the multi-point Pitot tube. The strongest swirl is detected in the case of $90^{\circ}$ dual elbow combination of all. In addition, it is observed that flow separation remains unchanged and occurs at the same point irrespective of various upstream dual elbow combinations.

  • PDF

Fire Detection of a Building Using Wireless Multi-point Temperature Sensors (무선 다점 온도센서에 의한 빌딩의 화재 탐지)

  • Kim, Chi-Yeop;Kwon, Il-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.494-498
    • /
    • 2004
  • Fire accidents often happen in large buildings because large buildings are equipped with heavy electrical wiring and piping. When fire is to be occurred in those buildings, it is very dangerous to People and building structures. Therefore, multi-point wireless temperature sensors for large buildings are necessary in order to detect fire in the early time and thus to minimize the loss. A wireless device was composed of the transmitter and receiver. The specification of this device was as follows: 915MHz of transmitted frequency, 4 channels, 9600bps of the transmitted speed, and 10mW of the transmitted power. We confirmed through experiment that the temperature was well sensed and fire location was determined by the 4 channel sensors of the developed sensor system.

A Implementation of Electronic Measurement Datum Point Monitoring S/W based on Object-Oriented Modeling for Multi Purpose and High Availability (다목적 및 고활용성을 위한 객체지향 모델링 기반의 전자 측량기준점 모니터링 S/W 구현)

  • Jung, Se-Hoon;Sim, Chun-Bo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.2
    • /
    • pp.99-112
    • /
    • 2015
  • Datum point for displaying location and altitude of point has being advantage usefully in various measurement parts. However, datum point has been increasing loss cases owing to weather changes and stratum changes and neglecting meaninglessly. In this paper, we design and implement a multi electronic measurement system monitoring software with functions such as include maximize utilization of existing measurement datum system as well as collected various environment data and detection stratum changes of surround area. Proposed software is implemented to support that reusability and extensibility of software using object oriented modeling method. Our software supports a GUI for electronic measurement datum point administrator as well as for web user and mobile user. Our system can support a graph GUI for various data analysis and reposition in realtime to database that measured location information and various sensing information to prevent loss of electronic measurement datum point and to detected stratum changes. In addition, we include a QR code and RFID recognition function. Finally, we suggest performance evaluation result to confirm stratum changes detection and GPS location error rate.