• Title/Summary/Keyword: Multi-channel tube

Search Result 43, Processing Time 0.032 seconds

Combustion synthesis of carbon nanotubes using their self-catalytic behavior (자기촉매 특성을 이용한 탄소나노튜브의 연소합성 연구)

  • Woo, Sang-Kil;Hong, Young-Taek;Kwon, Oh-Chae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1815-1820
    • /
    • 2008
  • Self-catalytic behavior of combustion-synthesized carbon nanotubes (CNTs) is evaluated using a double-faced wall stagnation flow burner with a CNT-deposited stainless steel plate wall. CNT formation is observed using field-emission scanning and transmission electron microscopies and Raman spectroscopy. A self-catalytic behavior of multi-walled CNTs (MWCNTs) shows the enhanced ratio of channel diameter to tube wall thickness and the enhanced intensity ratio of G-band to D-band in Raman spectroscopy, implying that the quality of metal-catalytic, flame-synthesized MWCNTs can be much improved via a CNT self-catalytic flame-synthesis process. Thus, using a DWSF burner through the self-catalytic process has potential in mass production of CNTs having much improved quality.

  • PDF

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.

A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A (비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구)

  • Lee, Jeong-Kun;Min, Kyung-Ho
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Influencer Attribute Analysis based Recommendation System (인플루언서 속성 분석 기반 추천 시스템)

  • Park, JeongReun;Park, Jiwon;Kim, Minwoo;Oh, Hayoung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1321-1329
    • /
    • 2019
  • With the development of social information networks, the marketing methods are also changing in various ways. Unlike successful marketing methods based on existing celebrities and financial support, Influencer-based marketing is a big trend and very famous. In this paper, we first extract influencer features from more than 54 YouTube channels using the multi-dimensional qualitative analysis based on the meta information and comment data analysis of YouTube, model representative themes to maximize a personalized video satisfaction. Plus, the purpose of this study is to provide supplementary means for the successful promotion and marketing by creating and distributing videos of new items by referring to the existing Influencer features. For that we assume all comments of various videos for each channel as each document, TF-IDF (Term Frequency and Inverse Document Frequency) and LDA (Latent Dirichlet Allocation) algorithms are applied to maximize performance of the proposed scheme. Based on the performance evaluation, we proved the proposed scheme is better than other schemes.

An Experimental Study of the Flow Characteristics around 2D Multi-Cylinders ( I ) (2차원 다원주 주위의 유동 특성에 관한 실험적 연구 ( I ))

  • 김두홍;조철희;정우철;박찬원;나인삼
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.190-195
    • /
    • 2001
  • Flow patterns are very complex and interactive between cylinders. The patterns are turbulent and non-linear caused by various factors. In this paper, flow patterns and pressure gradient around vertical cylinders were investigated by experiment. Changing gaps between cylinders the flow patterns are measured at a fixed coming velocity. Flow patterns showed very complex and closely related to the coming velocity and cylinder space. The pressure gradient around the flow field is observed by twelve hole pitot tubes and manometer. The experiment has been conducted in circulating water channel with PIV system. That can visualize flow patterns. The laser beam was used to reflect the image from particles and recorded by CCD camera. The cylinders were spaced from ID to 5D with 0.5m/sec of incoming flow velocity. The experimental results using pitot tube showed in good agreement with results of precious by others study. The results can be applied in the understanding and design of multiple pile array structures.

  • PDF

The Immersion Factors and Characteristics of Youtube Channels for Generation Z (Z세대가 즐기는 유튜브 채널의 몰입 요인과 특징)

  • Kang, MinJeong;Jeong, Eun-Ju;Cho, Hae-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.2
    • /
    • pp.150-161
    • /
    • 2020
  • Generation Z(Gen Z), which is referred to people in their late teens to early 20s, becomes one of new major consumer groups in the society. More than 80 percent Gen Z use YouTube content as a main information channel. In this study, we investigate what kind of factors make Gen Z immersed when watching YouTube content. In the background study, we examined immersion and set the cognitive conditions of immersion as reality, fascination, control, and driving as a framework for analysis of case study. In the case study, we analyzed the most popular YouTube channels of each category among the Gen Z with the established framework and then identified 3 main factors: reality, 5 senses, and unpretentiousness and 8 characteristics of them. By conducting survey with Gen Z, we wanted to verify the validity of the characteristics and find out the difference among categories. Subjects answered on a five-point scale how the characteristics of each immersion factor corresponded to their favorite channels. As a result, seven characteristics: 1) familiarity of background, 2) reality of acting, 3)familiarity of material, 4)YouTubers' appearance and 5) voice, 6)multi-sensory, and 7)YouTuber's ability to resemble viewers influenced more than 50% of users' immersion. Although there was no significant difference among categories, the familiarity of the material and the five senses stimulus (YouTube's appearance, voice, audiovisual and surrogate taste) were the most important factors in the entertainment category.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Development of Multi-channel Detector of X-ray Backscatter Imaging (후방산란 엑스선 영상획득을 위한 다채널 검출기 개발)

  • Lee, Jeonghee;Park, Jongwon;Choi, Yungchul;Lim, Chang Hwy;Lee, Sangheon;Park, Jaeheung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.245-247
    • /
    • 2022
  • Backscattered x-ray imaging is a technology capable of acquiring an image inside an irradiated object by measuring X-rays scattered from an object. For image acquisition, the system must include an X-ray generator and a detection system for measuring scattered x-rays. The imaging device must acquire a real-time signal at sampling intervals for x-rays generated by passing through a high-speed rotating collimator, and for this purpose, a high-speed signal acquisition device is required. We developed a high-speed multi-channel signal acquisition device for converting and transmitting signals generated by the sensor unit composed of a large-area plastic scintillator and a photomultiplier tube. The developed detector is a system capable of acquiring signals at intervals of at least 15u seconds and converting and transmitting signals of up to 6 channels. And a system includes remote control functions such as high voltage, signal gain, and low level discrimination for individual calibration of each sensor. Currently, we are conducting an application test for image acquisition under various conditions.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF