• Title/Summary/Keyword: Multi-chamber

Search Result 309, Processing Time 0.039 seconds

Study for Conductive and Non-conductive Multi-layers Depth Profiling Analysis of Radio Frequency Gas-jet Boosted Glow Discharge Spectrometry (Modified Gas-jet Boosted Radio-frequency Glow Discharge 셀의 개발 및 최적화에 관한 연구)

  • Cho, Won Bo;Borden, Stuart;Jeong, Jong Pil;Kang, Won Kyu;Kim, Kyu Whan;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • The new system using a glow discharge atomic emission spectrometer for the direct analysis of solid samples has been developed and characterized. The system was consisted of new glow discharge cell improved previous gas-jet boosted nozzle and radio-frequency power supply. In the case of previous type glow discharge chamber, it had been fitted trace analysis of low alloy steel with low discharge power, because it was to decrease redeposition and increase sample weight loss. But it had a problem that plasma becomes unstale due to increased sample weight loss and redeposition resulting from the high discharge power. Because of being problem of previous glow discharge, it is impossible to analyze using high power. The modified gas-jet boosted glow discharge to solve this problem would improve to be less sample loss rate of modified nozzle than sample loss rate of previous nozzle on the equal discharge condition, and improve to increase stability of plasma. The effect of discharge parameters such as discharge pressure, gas flow rate and power on the sample loss rate, emission intensity has been studied to find optimum discharge conditions. The calibration curves of Fe were obtained with 3 low-alloy samples.

Evaluation on the Greenhouse Gas Emission According to the Intake Levels of Total Mixed Rations of Hanwoo Cow (급여수준에 따른 한우 암소의 온실가스 배출량 평가)

  • Kim, Du-Ri;Ha, Jae-Jung;Kim, Jong-Taek;Song, Young-Han
    • Journal of Animal Science and Technology
    • /
    • v.53 no.5
    • /
    • pp.475-480
    • /
    • 2011
  • This study was conducted to investigate the effects of different feeding level of TDN (Total Digestible Nutrients) on the generation of main greenhouse gases such as carbon dioxide and methane in Hanwoo cows. The diet TDN (kg) adjusted to achieve ADG of 0 g/day (Control), 200 g/day (T1), and 400 g/day (T2) of the maintenance level TMR (Total Mixed Ration) delivered twice a day at 08:30 and 17:30. Cow are housed in a respiration chamber and the environmental temperature was maintained at $20^{\circ}C$. The gases were measured for 24 hours using the multi-detector instrument Mamos-300. The analyzed methane emissions of T1 and T2 were 33.5% and 69.6% higher than control, respectively, and the carbon dioxide emissions were 21.1% and 40.6% higher than control. Also, the hourly pattern of carbon dioxide and methane production were showed very similar emission. Gas production showed peak after 1 hour of feeding and this gap was wider in the afternoon than in the morning hours. It is clearly conducted that $CO_2$ and $CH_4$ emissions were different by limited intake levels of feed.

A COMPARISON OF RELEASE RATE AND CUMULATIVE RELEASE OF TEGDMA WITH OR WITHOUT THE APPLICATION OF BONDING RESIN (접착레진 적용 유무에 따른 TEGDMA의 방출속도 및 방출량 비교)

  • Shin, Hee-Jung;Jeon, Seong-Min
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.701-709
    • /
    • 1998
  • Many dental composites are Bis-GMA based resin which diluted with the more fluid monomer triethylenglycol dimethacrylate(TEGDMA). TEGDMA is often present in exess so that some quantity remains unreacted following photo-initiated polymerization. TEGDMA is a component of some resin composites which contributes to their cytotoxicity. The presence of dentin between resin composite and pulp space reduce the cytotoxicity in vitro. The root system from extrcted human third molar was removed and then a circular occlusal cavity 4mm in diameter was prepared, leaving a remaining dentinal thickness to the roof of the pulpal chamber within the range 1.0-1.5mm. Dentine was treated with 37% phosphoric acid prior to Z 100 placement without using bonding resin(group 1). In group 2, SMP(Scotchbond Multi Purpose) primer, bonding resin prior to Z 100 placement were applied sequently. In group 3, moulds with internal dimensions 4mm diameter by 2mm depth were used to contain the composite alone with an equvalent mass on tooth model, and then they were immersed directly into water. The purpose of this study is to evaluate the release rate and quantity of TEGDMA with or without the application of bonding resin. Both release rate and total cumulative amount of TEGDMA for the three groups were determined using reversed-phase HPLC at times up to 10 days. The results were as follows: 1. All experimental groups showed the highest rate of release was in the first sample period(0-4.32 min) and the rate of release declined exponentially thereafter. 2. The maximum release rate and total cumulative account of TEGDMA in the tooth model of group 1 and group 2 with the use of SMP bonding resin were reduced however ther were no significant differences between these groups(P>0.05). 3. In the first sample period(0-4.32 min), the rate of release of TEGDMA from composite resin in group 3 immersed directly into water was significantly higher than that in group 1 and group 2 of tooth model(P<0.05). Conclusively, TEGDMA diffusion from Z 100 resin was not effectively prevented by the presence of dentin in spite of using the SMP bonding resin.

  • PDF

The effect of trypsin and chymotrypsin on the chemotaxis and activation of eosinophil (Trypsin과 chymotrypsin이 호산구 화학주성 및 활성화에 미치는 효과)

  • Lee, Myung-Goo;Kim, Myung-Bin;Kim, Jin-Hwan;Yun, Taek Joong;Choi, Jeong-Eun;Kim, Dong-Hwan;Mo, Eun-Kyung;Park, Myung-Jae;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.359-366
    • /
    • 1996
  • Background : Eosinophilic leukocytes are prominent cellular participants in the pathogenesis of allergic disease and asthma. Chemotaxis is still a very useful method in evaluating the response of human eosinophil to novel modulators. Degranulated mast cells and activated T lymphocytes are responsible for the pathophysiology of asthma and tryptase is one of most important proteases released after activation of mast cells. The purpose of this study was to investigate the actions of trypsin and chymotrypsin on eosinophils in terms of chemotaxis and activation. Method : Eosinophils were isolated by negative immunoselection from the peripheral blood of atopic donors. Chemotaxis was studied by using micro-Boyden chambers and ECP release was assayed by fluoroimmunoassay. Results : Eosinophil showed a chemotactic response to trypsin. Maximal chemotactic response was with $1000{\mu}g/ml$ trypsin ($56.52{\pm}14.50$/HPF) which was comparable to PAP. But chymotrypsin showed no significant chemotactic response to eosinophils. Trypsin at the concentration of 10, 100, $1000{\mu}g/ml$ induced secretion of ECP, which at the concentration of $10{\mu}g/ml$ represented about 2.7 times of the spontaneous rate of release. Soybean protease inhibitor reduced trypsin induced ECP release. Conclusion : Trypsin can induce chemotactic response to eosinophils and activation of eosinophils that can induce secretion of ECP. On the contrary, chymotrypsin showed no direct effect on eosinophils. We propose a role of trypsin on the chemotaxis and activation of eosinophils.

  • PDF

Development of UHF Band Tag Antenna using Radio Frequency Identification Multipurpose Complex Card (RFID 다기능 복합 카드용 UHF 대역 소형 태그 안테나 개발)

  • Byun, Jong-Hun;Sung, Bong-Geun;Choi, Eun-Jung;Ju, Dae-Geun;Yoo, Dae-Won;Cho, Byung-Lok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1452-1458
    • /
    • 2009
  • In this paper, Our proposed Multipurpose Complex Card UHF band RFID small-size Tag antenna. Multi purpose Complex Card UHF band RFID small-size Tag antenna that is to minimize the low efficiency of RFID Tag Read Range that generates space limitation and a conductor surrounded by inducing fingerpring system with dual(HF, UHF) Card is presented. Our proposed UHF band RFID small-size Tag antenna is for the Multipurpose Complex Card that is mounted on the fingerpring system as well as the HF Tag. It also enables to minimize and facilitates Tag chip matching by adjusting Tapered, Meander line and Loop structure. Given the card substance properties and periphery circuit, the proposed small-size Tag antenna, in this report, is designed with PET film with size of $50{\times}15mm^2$. The RFID small-size Tag method for measurements is used by EPCglobal Static Test instrument in Anechoic Chamber, which is tested with dual Card, within the car and in wallet. It is found that Read Range is 3.8m from the EPCglobal Static Test, Maximum Read Range within the car from the field test results in 7.6m. Proposed Tag antenna is will be used in the parking control security system.

The Patient Specific QA of IMRT and VMAT Through the AAPM Task Group Report 119 (AAPM TG-119 보고서를 통한 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Kim, Jong-Ha;Park, Seung;Lee, Keun-Sub;Sohn, Seung-Chang;Shin, Young-Joo;Kim, Yon-Lae
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.255-263
    • /
    • 2012
  • The aim of this study was to evaluate the patient specific quality assurance (QA) results of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) through the AAPM Task Group Report 119. Using the treatment planning system, both IMRT and VMAT treatment plans were established. The absolute dose and relative dose for the target and OAR were measured by using an ion chamber and the bi-planar diode array, respectively. The plan evaluation was used by the Dose volume histogram (DVH) and the dose verification was implemented by compare the measured value with the calculated value. For the evaluation of plan, in case of prostate, both IMRT and VMAT were closed the goal of target and OARs. In case of H&N and Multi-target, IMRT was not reached the goal of target, but VMAT was reached the goal of target and OARs. In case of C-shape(easy), both were reached the goal of target and OARs. In case of C-shape(hard), both were reached the goal of target but not reached the goal of OARs. For the evaluation of absolute dose, in case of IMRT, the mean of relative error (%) between measured and calculated value was $1.24{\pm}2.06%$ and $1.4{\pm}2.9%$ for target and OAR, respectively. The confidence limits were 3.65% and 4.39% for target and OAR, respectively. In case of VMAT the mean of relative error was $2.06{\pm}0.64%$ and $2.21{\pm}0.74%$ for target and OAR, respectively. The confidence limits were 4.09% and 3.04% for target and OAR, respectively. For the evaluation of relative dose, in case of IMRT, the average percentage of passing gamma criteria (3mm/3%) were $98.3{\pm}1.5%$ and the confidence limits were 3.78%. In case of VMAT, the average percentage were $98.2{\pm}1.1%$ and the confidence limits were 3.95%. We performed IMRT and VMAT patient specific QA using TG-119 based procedure, all analyzed results were satisfied with acceptance criteria based on TG-119. So, the IMRT and VMAT of our institution was confirmed the accuracy.

The Evaluation of Image Quality and Radiation Dose in Multi-Detector CT (MDCT에서 화질과 방사선량에 관한 연구)

  • Han, Dong-Kyoon;Yang, Han-Joon;Kim, Moon-Chan;Ko, Shin-Gwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.129-138
    • /
    • 2007
  • The Purpose of this study is to suggest the basic data for making good quality image and maintaining equipment homeostasis by accepting image quality evaluation and radiation dose evaluation in Multi-detector CT. In this study we surveyed 14 CT equipments in Seoul. The results obtained were as follows ; CT number was $0.56{\pm}0.70\;HU$. Noise was $0.39{\pm}0.09\;HU$. Uniformity was $1.08{\pm}0.52\;HU$. High contrast resolution was $0.48{\pm}0.05\;mm$ and low contrast resolution was $3.65{\pm}1.16\;mm$. For CTDI, the central part and the peripheral part of head phantom were $43.2{\pm}15.4\;mGy$ and $45.6{\pm}17.5\;mGy$, respectively. For body phantom, the central part and the peripheral part of head phantom were $13.5{\pm}4.5$ and $29.2{\pm}10.2\;mGy$, respectively. CTDIw was $44.8{\pm}16.8\;mGy$ and CTDIw/100 mAs was $18.8{\pm}5.3\;mGy$ using head phantom. CTDIW was $24.0{\pm}8.3\;mGy$ and CTDIw/100 mAs was $10.1{\pm}2.5\;mGy$ using body phantom. Therefore, CT number, noise, high contrast resolution, low contrast resolution, CTDI, CTDIw and CTDIw/100 mAs of MDCT were showed excellently in all equipments.

  • PDF

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Recent research activities on hybrid rocket in Japan

  • Harunori, Nagata
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.1-2
    • /
    • 2011
  • Hybrid rockets have lately attracted attention as a strong candidate of small, low cost, safe and reliable launch vehicles. A significant topic is that the first commercially sponsored space ship, SpaceShipOne vehicle chose a hybrid rocket. The main factors for the choice were safety of operation, system cost, quick turnaround, and thrust termination. In Japan, five universities including Hokkaido University and three private companies organized "Hybrid Rocket Research Group" from 1998 to 2002. Their main purpose was to downsize the cost and scale of rocket experiments. In 2002, UNISEC (University Space Engineering Consortium) and HASTIC (Hokkaido Aerospace Science and Technology Incubation Center) took over the educational and R&D rocket activities respectively and the research group dissolved. In 2008, JAXA/ISAS and eleven universities formed "Hybrid Rocket Research Working Group" as a subcommittee of the Steering Committee for Space Engineering in ISAS. Their goal is to demonstrate technical feasibility of lowcost and high frequency launches of nano/micro satellites into sun-synchronous orbits. Hybrid rockets use a combination of solid and liquid propellants. Usually the fuel is in a solid phase. A serious problem of hybrid rockets is the low regression rate of the solid fuel. In single port hybrids the low regression rate below 1 mm/s causes large L/D exceeding a hundred and small fuel loading ratio falling below 0.3. Multi-port hybrids are a typical solution to solve this problem. However, this solution is not the mainstream in Japan. Another approach is to use high regression rate fuels. For example, a fuel regression rate of 4 mm/s decreases L/D to around 10 and increases the loading ratio to around 0.75. Liquefying fuels such as paraffins are strong candidates for high regression fuels and subject of active research in Japan too. Nakagawa et al. in Tokai University employed EVA (Ethylene Vinyl Acetate) to modify viscosity of paraffin based fuels and investigated the effect of viscosity on regression rates. Wada et al. in Akita University employed LTP (Low melting ThermoPlastic) as another candidate of liquefying fuels and demonstrated high regression rates comparable to paraffin fuels. Hori et al. in JAXA/ISAS employed glycidylazide-poly(ethylene glycol) (GAP-PEG) copolymers as high regression rate fuels and modified the combustion characteristics by changing the PEG mixing ratio. Regression rate improvement by changing internal ballistics is another stream of research. The author proposed a new fuel configuration named "CAMUI" in 1998. CAMUI comes from an abbreviation of "cascaded multistage impinging-jet" meaning the distinctive flow field. A CAMUI type fuel grain consists of several cylindrical fuel blocks with two ports in axial direction. The port alignment shifts 90 degrees with each other to make jets out of ports impinge on the upstream end face of the downstream fuel block, resulting in intense heat transfer to the fuel. Yuasa et al. in Tokyo Metropolitan University employed swirling injection method and improved regression rates more than three times higher. However, regression rate distribution along the axis is not uniform due to the decay of the swirl strength. Aso et al. in Kyushu University employed multi-swirl injection to solve this problem. Combinations of swirling injection and paraffin based fuel have been tried and some results show very high regression rates exceeding ten times of conventional one. High fuel regression rates by new fuel, new internal ballistics, or combination of them require faster fuel-oxidizer mixing to maintain combustion efficiency. Nakagawa et al. succeeded to improve combustion efficiency of a paraffin-based fuel from 77% to 96% by a baffle plate. Another effective approach some researchers are trying is to use an aft-chamber to increase residence time. Better understanding of the new flow fields is necessary to reveal basic mechanisms of regression enhancement. Yuasa et al. visualized the combustion field in a swirling injection type motor. Nakagawa et al. observed boundary layer combustion of wax-based fuels. To understand detailed flow structures in swirling flow type hybrids, Sawada et al. (Tohoku Univ.), Teramoto et al. (Univ. of Tokyo), Shimada et al. (ISAS), and Tsuboi et al. (Kyushu Inst. Tech.) are trying to simulate the flow field numerically. Main challenges are turbulent reaction, stiffness due to low Mach number flow, fuel regression model, and other non-steady phenomena. Oshima et al. in Hokkaido University simulated CAMUI type flow fields and discussed correspondence relation between regression distribution of a burning surface and the vortex structure over the surface.

  • PDF