• 제목/요약/키워드: Multi-Story Structure

검색결과 145건 처리시간 0.027초

Estimation of earthquake induced story hysteretic energy of multi-Story buildings

  • Wang, Feng;Zhang, Ning;Huang, Zhiyu
    • Earthquakes and Structures
    • /
    • 제11권1호
    • /
    • pp.165-178
    • /
    • 2016
  • The goal of energy-based seismic design is to obtain a structural design with a higher energy dissipation capacity than the energy dissipation demands incurred under earthquake motions. Accurate estimation of the story hysteretic energy demand of a multi-story structure is the key to meeting this goal. Based on the assumption of a mode-equivalent single-degree-of-freedom system, the energy equilibrium relationship of a multi-story structure under seismic action is transformed into that of a multi-mode analysis of several single degree-of-freedom systems. A simplified equation for the estimation of the story seismic hysteretic energy demand was then derived according to the story shear force and deformation of multi-story buildings, and the deformation and energy relationships between the mode-equivalent single-degree-of-freedom system and the original structure. Sites were categorized into three types based on soil hardness, namely, hard soil, intermediate hard (soft) soil, and soft soil. For each site type, a 5-story and 10-story reinforced concrete frame structure were designed and employed as calculation examples. Fifty-six earthquake acceleration records were used as horizontal excitations to validate the accuracy of the proposed method. The results verify the following. (1) The distribution of seismic hysteretic energy along the stories demonstrate a degree of regularity. (2) For the low rise buildings, use of only the first mode shape provides reasonably accurate results, whereas, for the medium or high rise buildings, several mode shapes should be included and superposed to achieve high precision. (3) The estimated hysteretic energy distribution of bottom stories tends to be underestimated, which should be modified in actual applications.

제약 조건 기반 서술구조를 이용한 동시 진행 이야기의 생성 (Creating Simultaneous Story Arcs Using Constraint Based Narrative Structure)

  • 문성현;김석규;홍의석;한상영
    • 한국콘텐츠학회논문지
    • /
    • 제10권5호
    • /
    • pp.107-114
    • /
    • 2010
  • 인터랙티브 스토리텔링 시스템(Interactive Storytelling System) 상에서 다양한 이야기의 진행과 결말을 표현할 수 있는 비선형적인 이야기(nonlinear story)는 사용자와의 상호작용으로 생성된다. 또한 연극이나 영화에서 관객은 하나의 장면에서 진행되고 있는 이야기만을 볼 수 있고 다른 장면의 이야기를 보기 위해서는 현재 장면이 끝난 후 다른 장면의 이야기를 볼 수 있다. 그러나 현실에서는 여러 가지 사건들이 여러 장소에서 동시에 발생하고 게다가 특정 사건들은 다른 사건들에 영향을 미치기 때문에 전체적인 이야기의 흐름에 큰 영향을 줄 수 있다. 본 연구에서는 비선형 스토리의 생성을 위한 제약 조건 기반의 서술구조(Constraint Based Narrative Structure)를 소개하고 동시 진행 이야기(Simultaneous Story Arcs)의 제어를 위한 멀티뷰포인트(multi viewpoint)를 제안한다.

Simulating the Response of a 10-Storey Steel-Framed Building under Spreading Multi-Compartment Fires

  • Jiang, Jian;Zhang, Chao
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.389-396
    • /
    • 2018
  • This paper presents a numerical investigation on the structural response of a multi-story building subjected to spreading multi-compartment fires. A recently proposed simple fire model has been used to simulate two spreading multi-compartment fire scenarios in a 10-story steel-framed office building. By assuming simple temperature rising and distribution profiles in the fire exposed structural components (steel beams, steel column and concrete slabs), finite element simulations using a three-dimensional structural model has been carried out to study the failure behavior of the whole structure in two multi-compartment fire conditions and also in a standard fire condition. The structure survived the standard fire but failed in the multi-compartment fire. Whilst more accurate fire models and heat transfer models are needed to better predict the behaviors of structures in realistic fires, the current study based on very simple models has demonstrated the importance and necessity of considering spreadingmulti-compartment fires in fire resistance design of multi-story buildings.

Optimal seismic retrofit design method for asymmetric soft first-story structures

  • Dereje, Assefa Jonathan;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • 제81권6호
    • /
    • pp.677-689
    • /
    • 2022
  • Generally, the goal of seismic retrofit design of an existing structure using energy dissipation devices is to determine the optimum design parameters of a retrofit device to satisfy a specified limit state with minimum cost. However, the presence of multiple parameters to be optimized and the computational complexity of performing non-linear analysis make it difficult to find the optimal design parameters in the realistic 3D structure. In this study, genetic algorithm-based optimal seismic retrofit methods for determining the required number, yield strength, and location of steel slit dampers are proposed to retrofit an asymmetric soft first-story structure. These methods use a multi-objective and single-objective evolutionary algorithms, each of which varies in computational complexity and incorporates nonlinear time-history analysis to determine seismic performance. Pareto-optimal solutions of the multi-objective optimization are found using a non-dominated sorting genetic algorithm (NSGA-II). It is demonstrated that the developed multi-objective optimization methods can determine the optimum number, yield strength, and location of dampers that satisfy the given limit state of a three-dimensional asymmetric soft first-story structure. It is also shown that the single-objective distribution method based on minimizing plan-wise stiffness eccentricity turns out to produce similar number of dampers in optimum locations without time consuming nonlinear dynamic analysis.

고려(高麗) 금동탑(金銅塔)을 통해 본 법주사(法主寺) 팔상전(捌相殿)의 구조형식계통(構造形式系統) (The Structural Lineage of Palsangjeon in Pubjoo Temple Analyzed through Gilt-bronze Pagoda in the Koryo Period)

  • 김경표
    • 건축역사연구
    • /
    • 제14권1호
    • /
    • pp.89-105
    • /
    • 2005
  • The central aim of this thesis is to see if the structure of Palsangjeon(捌相殿) in Pubjoo Temple(法住寺), a five sto wooden pagoda in Chosen(朝鮮) Dynasty, was handed down from the ancient and middle ages. This study was performed through an analysis of Gilt-Bronze Pagoda built in Koryo(高麗) period. In other words, it is aimed at analyzing which lineage the structure of Palsangjeonbelongs to as a wooden pagoda. In analyzing the structure of Palsangjeon, I attempted to find out its source from the remains of Koryo period prior to the Chosen Dynasty. Examples are the Gilt-Bronze Pagoda, built during the Koryo period. I have also examined its relationship with other existing wooden pagodas and remains. The analysis of Palsangjeon, a five story wooden pagoda in Chosen Dynasty, focuses on the following: First, I explored the possibilities of whether the structure of Palsangjeon was newly invented in Chosen Dynasty, or if it had been derived from the wooden pagodas in the Koryo period. Secondly, I tried to find out if the stable vertical planes, with a great successive diminution ratio, were derived from the middle age, i.e. Koryo period. The results of the study of Palsangjeon through Gilt-Bronze Pagoda analysis are as follows: 1. The structure of Gilt-Bronze Pagoda, a wooden pagoda from the Koryo period, is roughly classified into the accumulation type, using pipe pillars, and the one story type using whole pillars. In the accumulation type, stories are connected in either a flat format or an intervening format. The Gilt-Bronze Pagoda is mainly composed of pipe pillars, with some whole pillars. However, the central pillar was omitted in the building structure. Generally, the upper and lower stories are connected by pipe pillars in a crutch format. All the pillars, whether they are pipe pillars or whole pillars, used Naiten(內轉) technology. The Eave supporter has the Haang type(下昻) and the Muhaang type(無下昻). In most cases, high balustrades are furnished, but few tables of high balustrades have been found. The slanting roof formats have been handed down from Paekche(百濟), Silla(新羅), or Koryo(高麗). However, the structure of the octagon is assumed to be derived from Koguryo(高句麗). The structure of the Gilt-Bronze Pagoda from the Koryo period is mainly composed of accumulated flat squares, with some spire types. intervening format, the structure of Palsangjeon used whole pillars in a half story format in which upper level side pillars are installed on the lower level tie beam. From the Bronze Pagoda from the Koryo period, we can assume that the half story format of wooden pagodas that has stable vertical planes with a great successive diminution ratio was created during the mid-Koryo period at the latest and had been idly developed by the time of the Chosen Dynasty. 3. The whole pillars in Palsangjeon are also found in Gilt-Bronze Pagodas from the Koryo period. Hence, all of the pillars in Palsangjeon seem to have been handed down from the ancient construction technology. They were also used in the construction of wooden pagodas from the Koryo period. Therefore, it is assumed that Palsangjeon was constructed using the construction technology of the Chosen Dynasty that had been developed from the wooden pagoda construction technology of the Koryo period. The stable vertical planes with a great successive diminution ratio in Palsangjeon are derived from ancient Korean wooden pagodas, which have developed into indigenous Korean wooden pagodas with fairly stable vertical planes and a great design, in the half story format of Koryo and Chosen Dynasty. Therefore, it is assumed that the structure of Palsangjeon has a systematic relationship with traditional Korean wooden pagodas and is one of the indigenous Korean wooden pagoda structures. 4. In China, the intervening format has been mainly used between stories in multi-story architecture since the ancient days. At the same time, the flat format as also used in ancient and middle ages. However, the flat format was replaced by whole pillars during the Ming(明) and Manchu(淸) Dynasties, in favor of simple and compact construction. The half-story format, in which upper level side pillars are installed on tie beams, has been found in some cases, but it doesn't seem to have been the primary construction technology. Few traces of the half-story format have been found in multi-story architecture in Japan, and it has not been used as a general construction format. By contrast, the half-story format, which seems to have been derived from the Koryo period, was used as a general construction format in multi-story architecture of the Chosen Dynasty. The construction technology of multi-story architecture is related to that of multi-story wooden pagodas, but they have different production technologies. It seems that the structure of Palsangjeon did not just adopt the construction technology of multi-story architecture in the Chosen Dynasty, but it was developed from wooden pagodas in the Koryo period, including the Gilt-Bronze Pagoda. 5. Since the ancient days, most Chinese and Japanese wooden pagodas have adopted an accumulation type of structure using pipe pillars, with accumulated pointed towers. On the other hand, though most Korean wooden pagodas have also adopted an accumulation type of structure from the ancientdays, one story type using whole pillars was created in the Koryo and Chosen Dynasties. The wooden pagoda structure of Palsangjeon, with stable vertical planes in a half story format, is a unique Korean construction technology, different from the construction technologies of Chinese and Japanese wooden pagodas. This thesis clearly determined the structural characteristics of Palsangjeon. However, various remains have yet to be analyzed in depth, to establish an accurate construction technology system. In the beginning of this thesis, I had difficulty in precisely interpreting the internal structure of the Gilt-Bronze Pagoda from its appearance. However, in the process of study, the more serious problem was that there are few remains or ruins of multi-story architecture in ancient and the middle ages of Korea. Therefore, it is urgent to discover various remains in the future. This thesis succeeded in determining the structural characteristics of Palsangjeon. However, it fell short of clarifying the structural lineage of the stable vertical planes, although they show indigenous Korean architectural taste, representing the unique national emotion, and the construction format of multi-story wooden pagodas in Korea. I hope this is clarified in the future research.

  • PDF

하이브리드 중간층 지진 격리 시스템과 빌딩 구조물의 동시 최적화 (Simultaneous Optimization of Hybrid Mid-Story Isolation System and Building Structure)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.51-59
    • /
    • 2019
  • A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.

전통한옥의 도시집합주거로 발전 가능성 연구 (A Study on the Possibility of Model Development from Traditional Han-ok to Urban Clustering Housing Model in Korean Context)

  • 손승광
    • 한국주거학회논문집
    • /
    • 제19권3호
    • /
    • pp.71-81
    • /
    • 2008
  • A traditional Korean housing is a typical type which is contained life style, spatial organization and scape element of people who lived in Korea. In the hanok, people want to be live not only in human environment and traditional culture, but also modem urban housing as a high density. This article deals as follows: First, Hanok as urban housing would be composed in a housing lot, linear type layout, devide building, and cluster type. Second, Housing unit and configuration of Multi family housing can be used single story, second story, second story + single story, multi story and Hanok roofing. Thirds, structure of the building are traditional wooden, combined one of steel and wood or concrete and wood, and the building system in exterior and interior can be seperated into another system. Forth, Image of multi story Hanok A last, consistency of Hanok is not a repeat of an origin but application and creative aptitude of the origin, and multi family housing application of Hanok can be a trial creative.

Efficient seismic analysis of multi-story buildings

  • Lee, Dong Guen;Kim, Hee Cheul
    • Structural Engineering and Mechanics
    • /
    • 제4권5호
    • /
    • pp.497-511
    • /
    • 1996
  • The equivalent static force procedure and the response spectrum analysis method are widely used for seismic analyses of multi-story buildings. The equivalent static force procedure is one of the most simple but less accurate method in predicting possible seismic response of a structure. The response spectrum analysis method provides more accurate results while it takes much longer computational time. In the response spectrum method, dynamic response of a multi-story building is obtained by combining modal responses through a proper procedure such as SRSS or CQC method. Since all of the analysis results are expressed in absolute values, structural engineers have difficulties to combine them with the results obtained from the static analysis. Design automation is interrupted at this stage because of the difficulty in the decision of the most critical design load. Pseudo-dynamic analysis method proposed in this study provides more accurate seismic analysis results than those of the equivalent static force procedure since the dynamic characteristics of a structure is considered. And the proposed method has an advantage in combination of the analysis results due to gravity loads and seismic loads since the direction of the forces can be considered.

시공단계의 영향을 고려한 프리스트레스 콘크리트 다층 구조물의 해석 (Analysis of Multi-Story Prestressed Concrete Structure Considering the Effect of Construction Stage)

  • 전찬기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.213-223
    • /
    • 2001
  • This paper presents an analytical procedure for the time-dependent analysis of the multi-story prestressed concrete structure under the construction stage. To account for the actual structural behavior, the procedure considers the effects due to the construction interval and the time-dependent losses of prestress at every construction step on the entire structural response. A numerical study is performed to demonstrate the general validity of the approach and to quantitatively evaluate the effects resulted from the time-dependent behaviors during construction. Recommendations and conclusions are developed by comparisons with structural responses using the present and conventional methods of analysis. The comparative results show that both effects of sequential construction and time-dependent prestress losses should be considered for the construction stage analysis.

  • PDF

A Study on Optimum Distribution of Story Shear Force Coefficient for Seismic Design of Multi-story Structure

  • Oh, Sang Hoon;Jeon, Jongsoo
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.121-145
    • /
    • 2014
  • The story shear force distributions of most seismic design codes generally reflect the influences of higher vibration modes based on the elastic deformations of structures. However, as the seismic design allows for the plastic behavior of a structure, the story shear force distribution shall be effective after it is yielded due to earthquake excitation. Hence this study conducted numerical analyses on the story shear force distributions of most seismic design codes to find out the characteristics of how a structure is damaged between stories. Analysis results show that the more forces are distributed onto high stories, the lower its concentration is and the more energy is absorbed. From the results, this study proposes the optimum story shear force distribution and its calculation formula that make the damages uniformly distributed onto whole stories. Consequently, the story damage distribution from the optimum calculation formula was considerably more stable than existing seismic design codes.