• 제목/요약/키워드: Multi-Signal

검색결과 2,279건 처리시간 0.027초

다중센서 신호특성 최적화를 통한 와전류검사 신뢰성 개선연구 (The Study on Reliability Improvement in Eddy Current Inspection by Signal Characteristic Optimization of Multi-coil Array Probe)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제14권2호
    • /
    • pp.60-64
    • /
    • 2010
  • This paper introduces reliability improvement and time saving in eddy current inspection by signal characteristic optimization of multi-coil eddy current array probe. In the past, Multi-coil array probe and single probe were used for the gas turbine rotor surface inspection & defect evaluation. The multi-coil array probe was used for the broad area inspection. But the signal deviations among multi-coil array probe are maximum 28% in commercial probe. This differences were considered to impedance differences among coils, so it is very difficult to evaluate exact defect size. The signal deviations among multi-coil array probe are maximum 28% in commercial probe. So, single coil inspection was used for exact defect sizing. The purpose of this study is to improve signal deviations of multi-coil array probe. The introduced new technology can improves this deviation by adjusting input voltage in each coil. At first, apply same voltage in each coil and collect signal amplitude of each coil. And calculate new input voltage based on signal amplitude of each coil. If the signal amplitude deviation is within 5% among multi-coil array probe, the signal amplitude of multi-coil array probe is reliable. The proposed technology gives 2% signal deviation among multi-coil array probe. The proposed new technology gives reliability improvement and inspection time saving in eddy current inspection.

Design of a Fully Reconfigurable Multi-Constellation and Multi-Frequency GNSS Signal Generator

  • ByungHyun Choi;Young-Jin Song;Subin Lee;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.295-306
    • /
    • 2023
  • This paper presents a multi-frequency and multi-constellation Global Navigation Satellite System (GNSS) signal generator that simulates intermediate frequency level digital signal samples for testing GNSS receivers. GNSS signal generators are ideally suited for testing the performance of GNSS receivers and algorithms under development in the laboratory for specific user locations and environments. The proposed GNSS signal generator features a fully-reconfigurable structure with the ability to adjust signal parameters, which is beneficial to generate desired signal characteristics for multiple scenarios including multi-constellation and frequencies. Successful signal acquisition, tracking, and navigation are demonstrated on a verified Software Defined Radio (SDR) in this study. This work has implications for future studies and advances the research and development of new GNSS signals.

원자력발전소 다채널 신호의 온라인 진단방법 비교 (Comparison of On-Line Diagnotic Methods on Multi-Channel Signals in Nuclear Plant)

  • 이광대;양승옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.705-708
    • /
    • 2003
  • In this paper, we have evaluated the methods to generate the reference signal for the diagnosis of multi-channel signals. The channel signal integrity can be known by the difference between the reference signal and each channel value. The generation method of reference signal is important in the diagnosis of multi-channel measurement system. The continuous weighting average method rejects the abnormal signal using weighting method and makes the reference signal using sumation of all channel values. This gives the simple and reasonable reference signal. The principle component analysis, one of the multivariate analysis methods, and the neural network method give the reliable reference signal by using signal models, and learning algorithm. Two methods can make the reliable reference if all signals are normal, but any signal having the drift have an effect on the reference.

  • PDF

불요신호 특성이 우수한 다기능레이더 신호처리기 개발 (The Development of the Multi-function Radar Signal Processor Having the High Spurious Free Dynamic Range)

  • 이희영
    • 한국군사과학기술학회지
    • /
    • 제13권1호
    • /
    • pp.140-146
    • /
    • 2010
  • The multi-function radar can detect and track the low RCS targets. For this purpose the multi-function radar uses the pulse train waveform. because this waveform has high dynamic range and good SNR(Signal to Noise Ratio). But the spurious signals can also be detected by processing the pulse train waveform. Thus the multi-function radar signal processor must have the high SFDR(Spurious Free Dynamic Range). This paper describes the development of the multi-function radar signal processor having the high SFDR.

다중 생체 신호를 이용한 심장 자기공명영상 스마트 트리거 시스템 (Multi-biological Signal-based Smart Trigger System for Cardiac MRI)

  • 양영중;박진호;홍혜진;안창범
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.945-949
    • /
    • 2014
  • In cardiac magnetic resonance imaging (CMRI), heart and respiratory motions are one of main obstacles in obtaining diagnostic quality of images. To synchronize CMRI to the physiological motions, ECG and respiratory gatings are commonly used. In this paper multi-biological signal (ECG, respiratory, and SPO2) based smart trigger system is proposed. By using multi-biological signal, the proposed system is robust to the induced noise such as eddy current when gradient pulsing is continuously applied during the examination. Digital conversion of the multi-biological signal makes the system flexible in implementing smart and intelligent algorithm to detect cardiac and respiratory motion and to reject arrhythmia of the heart. The digital data is used for real-time trigger, as well as signal display, and data storage which may be used for retrospective signal processing.

Advanced Small-Signal Model of Multi-Terminal Modular Multilevel Converters for Power Systems Based on Dynamic Phasors

  • Hu, Pan;Chen, Hongkun;Chen, Lei;Zhu, Xiaohang;Wang, Xuechun
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.467-481
    • /
    • 2018
  • Modular multilevel converter (MMC)-based high-voltage direct current (HVDC) presents attractive technical advantages and contributes to enhanced system operation and reduced oscillation damping in dynamic MMC-HVDC systems. We propose an advanced small-signal multi-terminal MMC-HVDC based on dynamic phasors and state space for power system stability analysis to enhance computational accuracy and reduce simulation time. In accordance with active and passive network control strategies for multi-terminal MMC-HVDC, the matchable small-signal stability models containing high harmonics and dynamics of internal variables are conducted, and a related theoretical derivation is carried out. The proposed advanced small-signal model is then compared with electromagnetic-transient and traditional small-signal state-space models by adopting a typical multi-terminal MMC-HVDC network with offshore wind generation. Simulation indicates that the advanced small-signal model can successfully follow the electromechanical transient response with small errors and can predict the damped oscillations. The validity and applicability of the proposed model are effectively confirmed.

고속 도플러 편이 환경에서 최적 시간지연을 갖는 다중모드 모노펄스 신호처리에 관한 연구 (Study on Multi-Mode Monopulse Signal Processing System Providing Optimal Time Delay under High Doppler Condition)

  • 이재문;임재성;안희수
    • 한국군사과학기술학회지
    • /
    • 제19권5호
    • /
    • pp.582-589
    • /
    • 2016
  • Multi-mode monopulse system is widely used for satellite terminal like UAV because of high tracking accuracy and low size/weight profile. In order to calculate tracking error, Multi-mode monopulse system utilizes high-order mode signal, and it should have enough C/N(carrier to noise) level therefore tracking system needs narrow band filtering of received satellite beacon signal as much as possible. However, UAV suffers for beacon frequency drift derived from Doppler effect due to satellite figure 8 movement and UAV maneuvering. Therefore wideband signal processing needs to be considered in advance for exact doppler compensation and consequent time delay. In this paper, we propose the multi-stage Digital Signal processing system for beacon signal, which could minimize the signal delay under high Doppler and low C/N condition.

다층형 결합 선로를 이용한 반송파 복원 회로 설계 제작 (Design and fabrication of PSK carrier recovery circuit using multi-layer coupled line)

  • 김영완
    • 한국정보통신학회논문지
    • /
    • 제13권10호
    • /
    • pp.2039-2044
    • /
    • 2009
  • 본 논문에서는 다층형 결합 선로를 이용한 PSK 반송파 신호 복원 회로를 해석하고 설계 제작한다. 다층형 결합 선로 구조의 coupled line으로 구성되는 반송파 복원 6단자 소자는 다층형 구조를 가지며, 수신 전처리부의 6 단자 위상 상관기 구조와 동일한 구조를 갖는 일원화된 수신 구조 구현이 가능하다. 아울러 다층 결합 선로 6 단자 위상 상관기를 이용한 RML 기반 다중 모드 동기 복조형 반송파 신호 복원이 가능한 다층형 결합 선로 반송파 복원 회로 구조를 제안한다. 설계 제작된 다층형 결합 선로 구조 반송파 복원회로에 의한 직교 위상편이 방식 신호의 반송파 신호는 일정한 위상값과 반사 소자에 의해 발생되는 ${\pm}3o$ 이내인 위상차를 갖는 양호한 PSK 반송파 신호 특성을 나타내었다.

전달 시간차 방식 다회선 초음파 가스 유량계 개발 (Study on the Development of Multi-Path Ultrasonic Gas Flowmeter)

  • 황원호;박상국;이치환;장경영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF