• Title/Summary/Keyword: Multi-Path Entrance

Search Result 10, Processing Time 0.023 seconds

A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter (습식 다회선 초음파유량계의 특성평가 연구)

  • Lee, Dong-Keun;Cho, Yong;Ko, Jae-Myoung;Park, Tae-Jin;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

Characteristics of Closed Circuit Cooling Tower with Multi Path on Cooling Water Inlet Conditions (냉각수 변화에 따른 멀티패스 밀폐식 냉각탑의 성능)

  • Shim, Gyu-Jin;Baek, Seung-Moon;Moon, Choon-Geun;Yoon, Jung-In;Kim, Eun-Pil;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.597-602
    • /
    • 2008
  • The experiment of performance about closed-wet cooling tower(CWCT) was conducted in this study. The test section has the cooling water that flows from top part of a heat exchanger that has an entrance of cooling water with one and multi path. The heat exchanger consists of 15.88mm tubes with ten rows and ten columns and staggered arrangement. In this experiment, heat and mass transfer coefficients and range are calculated with variations of cooling water and path. The results indicated that operating CWCT using two path have the high values of heat and mass transfer coefficients and range than one path.

  • PDF

Analysis of Residents' Satisfaction for the Pedestrian Space of Multi-family Housing (공동주택단지 보행공간의 주민만족도 분석)

  • Kim, Cheol-Su;Kim, Hyo-Jun
    • Journal of the Korean housing association
    • /
    • v.22 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • This research analyzes the residents' satisfaction for the pedestrian space of multi-family housing based on quality index. For this purpose, nine apartment complexes which were built after 2000, are selected and examined by user characteristics of composition factors of pedestrian space. This research also compares residents' satisfaction by evaluation factors of walking environment. The resident survey reveals that the composit type of apartment gives the highest satisfaction to residents followed by a courtyard type, and a straight type the last. In particular, residents show high satisfaction to pedestrian-only space in the case of the composit type of apartment building. The most important factor of walking environment on residential satisfaction is the separation of car and pedestrian path of main entrance. Above all, suitability of construction laws and regulations should be reviewed for safer and more amenable walking environment.

Hydrodynamic forces of impeller shroud and wear-ring seal on centrifugal pump (고성능 원심펌프에서 임펠러 시라우드 및 마모 시일의 유체가진력 해석)

  • Ha, Tae-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.102-110
    • /
    • 1998
  • The analysis of lateral hydrodynamic forces in the leakage path between a shrouded pump impeller through wear-ring seal and its housing is presented. Governing equations are derived based on Bulk-flow and Hirs' turbulent lubrication model. By using a perturbation analysis and a numerical integration method, governing equations are solved to yield leakage and rotordynamic coefficients of force developed by the impeller shroud and wear-ring seal. The variation of rotordynamic coefficients of pump impeller shroud and wear-ring seal is analyzed as parameters of rotor speed, pressure difference, shroud clearance, wear-ring seal clearance, and circumferential velocity at the entrance of impeller shroud for a typical multi-stage centrifugal pump.

Heat Transfer Characteristics under Recirculation zone of Ramjet Combustor (재순환 영역이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Lee, Keon-Woo;Oh, Min-Keun;Ham, Hee-Chul;Hwang, Ki-Young;Cho, Hyung-Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.9-17
    • /
    • 2007
  • This experimental study has been conducted to investigate the effect of the recirculation zone on the multi-slot film cooling in the ramjet combustor. The recirculation zone which is generated by the protrusion tip on the entrance of the coolant flow path affects on the first slot. Velocity fields, dimensionless temperature fields and adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

Study of the Slot Film Cooling under Ramjet Combustor with Recirculation Zone (재순환 영역이 존재하는 램제트 연소실 슬롯 막냉각 연구)

  • Oh Min-Geun;Park Kwang-Hoon;Byun Hae-Won;Yu Man-Sun;Cho Hyung-Hee;Ham Hee-Cheol;Bae Joo-Chan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.59-63
    • /
    • 2005
  • The experimental study has been conducted to investigate the effect of the recirculation zone on the multi-slot film cooling in the ramjet combustor. The recirculation zone which is generated by the protrusion tip on the entrance of the coolant flow path affects on the first slot. Velocity fields, dimensionless temperature fields and adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by the share layer and high turbulence intensity between separated flows and coolant flows.

  • PDF

Influence of Flame Holder on Film Cooling Effectiveness of Ramjet Combustor (화염안정기 형상이 램제트 연소실에서의 슬롯 막냉각 특성에 미치는 영향)

  • Lee, Keon-Woo;Song, J.;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.315-320
    • /
    • 2008
  • This experimental study has been conducted to investigate the effect of the flame holder on the multi-slot film cooling in the ramjet combustor. The turbulent wake which is generated by the flame holder on the entrance of the coolant flow path affects on the slot. Adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

  • PDF

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 무선 센서네트워크 환경구축을 위한 무선 스펙트럼 분석 및 전송시험에 관한 연구)

  • An, Tea-Ki;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3220-3226
    • /
    • 2011
  • In order to monitor internal risk factors such as fire, terror, etc. on the subway station, the surveillance systems using CCTV and various kinds of sensors have been implemented and recently, introduction of surveillance systems using an advanced IT technology, sensor network technology is tried on several areas. Since 2007, Korean government has made an effort to develop the intelligent surveillance and monitoring system, which can monitor fire, intrusion, passenger congestion, health-state of structure, etc., by using wireless sensor network technology and intelligent video analytic technique. For that purpose, this study carried out field wireless communication environment test on Chungmuro Station of Seoul Metro on the basis of ZigBee that is considered as a representative wireless sensor network before field application of the intelligent integrated surveillance system being developed, arranged and analyzed and ZigBee based wireless communication environment test results on the platform and waiting room of Chungmuro Station on this paper. Results of wireless spectrum analysis on the platform and waiting room showed that there is no radio frequency overlapped with that of ZigBee based sensor network and no frequency interference with adjacent frequencies separated 10MHz or more. As results of wireless data transmission test using ZigBee showed that data transmission is influenced by multi-path fading effect from the number and flow rate of passengers on the platform or the waiting room rather than effects from entrance and exit of the train to/from the platform, it should be considered when implementing the intelligent integrated surveillance system on the station.

A Study on Effectiveness and Warrant Analysis for Two-Way Left-Turn Lanes (양방향 좌회전차로(TWLTLs) 적용효과 분석 및 설치준거 연구)

  • Bae, Gwang-Su;Sim, Gwan-Bo;Song, Chang-Yong
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.65-77
    • /
    • 2007
  • A two-way left-turn lane is a continuous center left-turn lane that could be used as a deceleration and refuge area for both directions of left-turning vehicles. TWLTL's have been used effectively for access management treatment when applied to a highway that has wide-spread left turning traffic demand and a high-density of side streets. In this study, an effective analysis was carried out using a computer-based simulation tool, VISSIM, in order to evaluate performance and safety effects of TWLTLs and develop a warrant. In conclusion, the results indicated that there was a remarkable decrease of through and left-turning vehicle travel time delay on the main road and improvement of traffic safety.

Development and Effectiveness of Private Parking Information Algorithm (복합용도 초고층빌딩에 대한 개별주차정보제공 알고리즘 개발)

  • Kim, Young-Sun;Nam, Baek;Lee, Choul-Ki;OH, Young-Tae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.5
    • /
    • pp.13-21
    • /
    • 2013
  • Super high-rise buildings of combined use such as large shopping malls and multiplex etc. have larger parking facilities than general buildings and are characteristic of an increase in the number of the entrance and the exit connecting internal external space of the parking lot. These features cause a congestion of internal traffic by increasing car driving distance in the parking lot, and vehicle idling increases by drivers wander the parking lot in order to find parking space. In addition, they make drivers suffer from lots of difficulties due to parking including increasing their walking line after parking. Therefore, in this study, we developed individual parking information provision algorithm to specify the optimal parking place for drivers according to the purpose of visiting a building and the drivers' moving path, and selected new construction site for the second lotte world in order to evaluate the algorithm developed and performed evaluation. As a result of the evaluation, it was analyzed that in the case of applying the individual parking information provision algorithm compared to the existing parking information provision algorithm, moving distance in the parking lot decreases around 7.43~83.4%, and that in the case of $CO_2$ emission, it decreased about 47.7% on average, which indicates that the efficiency resulted from application of the individual parking information provision algorithm is very high as the application effects are tested.