• Title/Summary/Keyword: Multi-Cavity

Search Result 245, Processing Time 0.025 seconds

Effect of varying the coupling strength and section length on the self-pulsation characteristics of multisection index-coupled DFB lasers (다중 전극 Index-Coupled DFB 레이저에서 결합 세기 및 각 영역의 길이가 Self-Pulsation 동작 특성에 미치는 영향)

  • Kim, Sang-Taek;Kim, Tae-Young;Ji, Sung-Keun;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.85-98
    • /
    • 2005
  • As the number of compound cavity modes within the stopband of DFB sections decreases, the frequency of mode hopping decreases for the variation of $\Delta$λ$_{B}$, which represents the difference between the Bragg wavelengths of two DFB sections, so that the number of abrupt changes of pulsation frequencies decreases. In addition, the pulsation frequency varies continuously for the variation of the phase in a phase tuning section for a fixed $\Delta$λ$_{B}$. The number of compound cavity modes within the stopband decreases as the length of DFB sections increases and the length of a phase tuning section decreases. Thus stable self-pulsation operations for the variation of $\Delta$λ$_{B}$ and the phase in a phase tuning section could be obtained by proper selection of the coupling strength and the length of each section.ction.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

Fabrication of tunable all-fiber feedback laser and its application (파장가변이 가능한 완전 광섬유형 궤환 레이저 구현 및 응용)

  • Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1220-1225
    • /
    • 2009
  • In this paper, a tunable fiber feedback laser based on the use of Sagnac loop filter and fiber Bragg grating (FBG) is proposed. The Sagnac loop filter using a high birefringence fiber provides precise 0.33-nm channel spacing as a multi-wavelength grid filter. Ni-Cr wire wound on the FBG is useful to induce the thermo-optic effect of the fiber. Two types of FBG structures, which have a different length of wire, are demonstrated to show the wavelength shift and separation. To tune FBG by resistant heat, some current is supplied into the wire. When the wavelength matched with one of the cavity modes of Sagnac loop filter, the mode-locked lasing is occurred. The electrical power sensitivity of the resonant wavelength is measured to 1.75pm/mW. This laser configuration can be applied the electrical power system for monitoring the power fluctuation.

Influence on Oral Health Condition by Visits to Dental Clinics and Dental Education Experience of East Asian Immigrant Women in Korea (동아시아 국내 이주여성의 치과방문여부와 구강건강교육유무가 구강건강상태에 미치는 영향)

  • Yun, Hyun-Kyuong;Choi, Mi-Sook;Choi, Gyu-Yil
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.409-417
    • /
    • 2012
  • Objectives : The purpose of this study is to figure out and establish the basic data that can help improve management of oral healthcare for the international marriage immigrant women. Methods : In this sense, we surveyed questions on 237 women out of 1,300 immigrant women, who have participated in the program by multi-cultural household supporting center, in a fashion of face-to-face investigation and on-the-spot direct cavity inspection simultaneously from May 1 to October 31, 2010. Collected data were electro-statistically computerized under SPSS 17.0 program and analyzed with frequency analysis, recurrence analysis and logistic regression analysis respectively. Results : The number of filled teeth got lower when they had lower number of dental visits. Women from the Philippines had the highest number of defect teeth, and the number of fixed prosthetic appliance became less when they had less number of dental visits. When they had no experience of oral health education, they had less fixed prosthetic appliances. There was higher percentage of periodontal disease when they did not have dental visit compared with the dental visit cases. Conclusions : Preparation of a policy for east Asian immigrant women for them to visit dentist comfortably and expansion of systematic oral health education are highly recommended.

The Effect of Green Tea Bag in Dogs with Periodontal Disease (개의 치주질환에 대한 녹차 티백의 효과)

  • Chang, Hwa-Seok;Hwang, Hee-Jung;Kang, Eun-Hee;Lee, Jae-Hoon;Chung, Dai-Jung;Yang, Wo-Jong;Chung, Wook-Hun;Kim, Dae-Hyun;Park, Woo-Dae;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • Ingredient analysis and the medical action of various teas are accomplished on multi angle. However, the research regarding the prevention and a treatment of oral cavity disease, which use the green tea, is still insufficient relatively. In this experiment, the virtue of green tea bag on periodontal disease was studied. This experiment was used in 11 beagles. As a test group, 6 beagles were rinsed their tooth with green tea bag. The remaining 5 beagles were rinsed with filter paper which was soaked with normal saline. The test found no statistical significance in gingival index, plaque index, calculus index and dental pocket depth. But the number of bacteria colonies decreased significantly in test groups. The periodontal disease is related to the number of bacterial colonies. Therefore, this results show that the green tea bag is effective for periodontal disease.

Reduction of Electromagnetic Interference between the LCD Driving Module and WWAN Antennas (LCD 구동 모듈과 WWAN 안테나 간의 전자기 간섭 감소에 대한 연구)

  • Kim, In-Bok;Park, Jin-Hyun;Kang, Il-Heung;Kim, Hong-Joon;Woo, Dong-Sik;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.716-722
    • /
    • 2012
  • In this paper, we analyzed the RF interactions between WWAN antennas and an LCD driving module inside the cover of a notebook computer, and discussed reduction method of RF coupling. In order to simulate the RF noise source from the LCD driving module, a multi-band antenna was designed and used with a simplified notebook model to test the RF coupling phenomena. We verified that the RF noise coupling is enhanced at certain frequencies due to cavity structure formed inside the notebook computer. Also, we showed that conductive barrier walls, which are inserted inside the notebook, could be effective in reducing RF coupling.

Multicentric T cell lymphosarcoma in a Jeju native boar

  • Yang, Hyoung-Seok;Kang, Sang-Chul;Jung, Ji-Youl;Roh, In-Soon;Kim, Dae-Yong;Bae, Jong-Hee;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.187-190
    • /
    • 2007
  • A 7-year-old Jeju native boar was requested to the Veterinary Pathology Laboratory of Cheju National University with a clinical signs of anorexia, melena, lethargy and sudden death. At necropsy, four coalescing firm masses were occupied in the abdominal cavity between ventral surface of stomach and pancreas. Individual mass was a yellowish white in color and up to 6 cm in diameter. These masses were not encapsulated and bulged from the cut surface. Liver and spleen were enlarged and pale nodules were presented in these tissues. Some yellowish white nodules up to 5 mm in diameter were scattered in kidneys. Histopathologically, lymphoblastic tumor cells were occupied in the abdominal masses, multifocal areas of liver, kidneys, and spleen. Morphologically lymphoblastic tumor cells were round to oval in shape, and medium to large in size. They had round to oval nuclei, moderate amount of eosinophilic cytoplasm, and many mitotic figures. Immunohistochemistry revealed that tumor cells were CD3-positive and $CD79{\alpha}$-negative, consistent with T-cell lineage. Based on gross, microscopic findings and immunohistochemistry, this case was diagnosed as porcine multi-centric T cell lymphosarcoma. In animals, as in human, the T-cell lymphomas are generally more aggressive than B cell types and respond less well to therapy. In our best knowledge, this is the first report for porcine T cell lymphosarcoma in Korea.

MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS (수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구)

  • Choi, Sang-Cheol;Park, Joon-Il;Kwom, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

Seismic Response Analysis Method for 2-D Linear Soil-Structure Systemsusing Finite and Infinite Elements (유한요소와 무한요소를 사용한 2차원 선형 지반-구조물계의 지진응답해석법)

  • 김재민;윤정방;김두기
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.231-244
    • /
    • 2000
  • This paper presents a dynamic analysis technique for a 2-D soil-structure interaction problem in the frequency domain, which can directly be applied as an analysis tool for seismic response analyses of underground structures, tunnels, embankments, and so on. In this method, the structure and near-field soil is modeled by the standard finite elements, while the unbounded far-field soil is represented using the dynamic infinite elements in the frequency domain. The earthquake-input motion is regarded as traveling P and SV waves which are incident vertically from the far-field of underlying half-space to the near-field of layered medium. The equivalent earthquake forces are then calculated utilizing so-called fixed-exterior-boundary-method and the free-field responses including displacements and tractions. For the verification of the present study, seismic response analyses are carried out for a multi-layered half-space free-field soil medium and a cylindrical cavity embedded in a homogeneous half-space. Comparisons of the present results with solutions by other approaches indicate that the proposed methodology gives accurate estimates. Finally, an application example of seismic response analysis for a subway station is presented, which demonstrates the applicability of the present study.

  • PDF

A High Speed CMOS Arrayed Optical Transmitter for WPON Applications (WPON 응용을 위한 고속 CMOS어레이 광트랜스미터)

  • Yang, Choong-Reol;Lee, Sang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.6
    • /
    • pp.427-434
    • /
    • 2013
  • In this paper, the design and layout of a 2.5 Gbps arrayed VCSEL driver for optical transceiver having arrayed multi-channel of integrating module is confirmed. In this paper, a 4 channel 2.5 Gbps VCSEL (vertical cavity surface emitting laser) driver array with automatic optical power control is implemented using $0.18{\mu}m$ CMOS process technology that drives a $1550{\mu}m$ high speed VCSEL used in optical transceiver. To enhance the bandwidth of the optical transmitter, active feedback amplifier with negative capacitance compensation is exploited. We report a distinct improvement in bandwidth, voltage gain and operation stability at 2.5Gbps data rate in comparison with existing topology. The 4-CH chip consumes only 140 mW of DC power at a single 1.8V supply under the maximum modulation and bias currents, and occupies the die area of $850{\mu}m{\times}1,690{\mu}m$ excluding bonding pads.