• Title/Summary/Keyword: Multi point injection

Search Result 47, Processing Time 0.026 seconds

Liquid LPG Spray Characteristics With Injection Pressure Variation;Comparison with Diesel Spray (분사압력변화에 따른 액체 LPG 분무특성;디젤분무와의 비교)

  • Lim, Hee-Sung;Park, Kweon-Ha
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.21-26
    • /
    • 1999
  • Liquefied petroleum gas(LPG) has been used as motor fuel due to its low emissions and low cost. The fuel feeding system has been improved with stringent requirement for exhaust emissions. LPG carburation system was firstly introduced, then the system changed into a gas injection system controlled precisely, but those gas feeding system has a limitation on improving power output. In order to improve an engine performance, a multi-point port injection system was introduced recently, and a liquid direct injection system into a cylinder was suggested as a next generation system to maximize a fuel economy as well as a power. This study addresses the analysis of the LPG spray from diesel injectors. The spray images are visualized and compared with diesel sprays in a wide injection pressure range. The photographs show much wider dispersion of LPG sprays.

  • PDF

A Fundamental Study of Air-Fuel Ratio Control on LPG Liquid Injection Engines (LPG 액체분사엔진의 공연비제어에 관한 기초 연구)

  • Sim, Han-Seop;Sunwoo, Myoungho;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.80-87
    • /
    • 2002
  • Liquefied petroleum gas (LPG) is used in spark ignition (SI) engines. Fuel injection rate of an injector is affected by fuel temperature and pressure in LPG liquid injection systems for either a multi-point-injection (MPI) or a direct injection (DI) engine. Even fuel injection conditions are varied, the air-fuel ratio should be accurately controlled to reduce exhaust emissions. In this study, a correction factor fur the fuel injection rate of an injector is derived from density ratio and pressure difference ratio. A compensation method of injected fuel amount is proposed for a fuel injection control system. The experimental results for the LPG liquid injection system in a SI engine show that this system works well fur a full range of engine speed and load condition, and the air-fuel ratio is accurately controlled by the proposed correction factor.

A Study on Evaporative Characteristics of Multi-component Mixed Fuels Using Mie Scattered Light and Shadowgraph Images (Mie 산란광법 및 Shadowgraph법을 이용한 다성분 혼합연료의 증발특성연구)

  • Yoon, Jun-Kyu;Myong, Kwang-Jae;Jiro Senda;Fujimoto Hajime;Cha, Kyung-Ok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.682-691
    • /
    • 2006
  • This study was conducted to assess the effect of mixed fuel composition and mass fraction on spray inner structure in evaporating transient spray under the various ambient conditions. Spray structure and spatial distribution of liquid phase concentration are investigated using a thin laser sheet illumination technique on the multi-component mixed fuels. A pulsed Ar+ laser was used as a light source. The experiments were conducted in a constant volume vessel with optical access. Fuel was injected into the vessel with electronically controlled common rail injector. Used fuel contain $i-octane(C_8H_{18}),\;n-dodecane(C_{12}H_{26})$ and $n-hexadecane(C_{16}H_{34})$ that are selected as low-, middle- and high-boiling point fuel, respectively. Experimental conditions are 25Mpa, 42MPa, 72MPa and 112MPa in injection pressure, $5kg/m^3,\;15kg/m^3\;and\;20kg/m^3$ in ambient gas density, 400K, 500K, 600K and 700K in ambient gas temperature, 300K and 368K in fuel temperature, and different fuel mass fraction. Experimental results indicate that the more high-boiling point component, the longer the liquid phase it were closely related to fuel physical properties, but injection pressure had no effect on. And there was a high correlation between the liquid phase length and boiling temperature at 75% distillation point.

On the new mold structure with multi-point gate for filling-balance mold (다점 핀포인트 금형에서 균형충전이 가능한 사출금형 구조)

  • Kwon, Youn-Suk;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.5
    • /
    • pp.25-29
    • /
    • 2008
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and ploymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system. The filling imbalance was desreased up to result range of $3{\leq}DFI{\leq}8(%)$ by using a new runner system for balanced filling.

  • PDF

On the new mold structure with multi-point gate for filling-balance mold (사출성형시 불균형 충전에 관한 다구찌 실험계획법을 이용한 성형공정의 최적화)

  • Hong, Youn-Suk;Han, Dong-Hyup;Jeong, Yeong Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system.

  • PDF

Microstructural Morphology of Molded Thin Composites of Thermotropic Liquid Crystalline Polymer and Polyamide 6 (서모트로픽 액정폴리머와 폴리아미드6으로 성형된 얇은 복합재료의 미세구조형태)

  • Choe, Nak-Sam;Choe, Gi-Yeong;Ha, Seong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1703-1711
    • /
    • 2000
  • Microstructural morphology of molded composites of thermotropic liquid crystalline polymer(LCP) and polyamide 6 (PA6) has been studied as a function of epoxy fraction. Injection-moulding of a thin composite plaque at a temperature below the melting point of the LCP fibrils by suing the extruded LCP/PA6 pellets produced multi-layered structures: 1) the surface skin layer with thickness of 65-120 ym exhibiting a transverse orientation, 2) the sub-skin layer with an orientation perpendicular to the surface skin, i.e. in the flow direction, 3) the core layer with arc-curved flow patterns. Similar microstructural orientations were observed in the respective layers for the composite plaques with different fractions of epoxy.

A Study on the NPC Type Multi-Level Energy Recovery Sustaining Driver for AC Plasma Display Panel (AC PDP용 NPC 타입 멀티레벨 에너지 회수회로에 관한 연구)

  • Yoo Jong-Gul;Hong Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.194-202
    • /
    • 2005
  • This paper proposes a new multi-level energy recovery sustaining driver for AC PDP(Plasma Display Panel), which solves the problems and maintains the merits of the conventional multi-level sustaining driver. While the conventional circuit improves the hard switching in the Weber circuit, there exist parasitic resonant currents in resonant inductors and Vs/2 sustaining period. Comparing the proposed circuit with the conventional circuit, the number of inductors are reduced by half, the parasitic resonant currents in resonant inductors are eliminated, and the hard switching problem is solved by CIM(Current Injection Method). Moreover the voltages across series-connected switching elements in the full bridge circuit are distributed equally by adopting NPC(Neutral Point Clamping) techniques. And circuit operations of the proposed circuit are analyzed for each mode and the validity is verified by the simulations using PSpice program and experimentation with a prototype drive circuit.

THE ANALYTIC ANALYSIS OF THE CORE INJECTION COOLING FLOW RATE FOR EMERGENCY WATER SUPPLY SYSTEM IN HANARO (하나로 비상 보충수 공급계통의 노심 주입 냉각유량 해석)

  • Park Yong-Chul;Kim Bong-Soo;Kim Kyung-Ryun;Wu Jong-Sub
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.39-44
    • /
    • 2005
  • In HANARO, a multi-purpose research reactor of 30 MWth, the emergency water supply system consists essentially of an emergency water storage tank located in the level of about thirteen meter (13 m) above the reactor core, a three inch ('3\%') diameter water injection pipe line including injection valves from the tank to the reactor cooling inlet pipe and a test loop to do periodic system performance test. When the water level of the reactor pool comes down to the extremely low due to a loss of reactor pool water accident the emergency water stored in the tank should be fed to the core by the gravity force and at that time the design flow rate is eleven point four kilogram per second (11.4 kg/s). But it is impossible periodically to measure the injection flow rate under the emergency condition because the normal water level should be maintained during the reactor operation. This paper describes a flow network analysis to simulate the flow rate under the emergency condition. As results, it was confirmed through the analysis results that the calculated flow rate agrees with the design requirement under the emergency condition.

  • PDF

Icing Characteristics of Liquid Phase LPG Injection According to Butane and Propane Mixing Rates (부탄과 프로판 혼합비율에 따른 액상 LPG 분사시 Icing 특성)

  • Kim, Yung-Jin;Cho, Won-Joon;Lee, Ki-Hyung
    • Journal of ILASS-Korea
    • /
    • v.16 no.3
    • /
    • pp.146-151
    • /
    • 2011
  • LPG(Liquified Petroleum Gas) fuel for vehicles has lots of advantages such as low emission level, cheaper fuel cost and enough infrastructure. Therefore it arouses interest as an alternative engine to reduce emission of diesel engines. Especially MPI(Multi Point Injection) type LPLi(Liquid Phase LPG injection) system could have overcome the disadvantages of mixer types such as low engine performance, decreased charging efficiency and cold starting difficulty. However ice formation on the nozzle tip and intake port due to the freezing of moisture around the components is often observed in LPLi systems. This icing phenomenon is the direct cause of unstable engine combustion, resulting in engine emissions. Therefore in this research, a spray visualization test for LPG injection was carried out to obtain the basic information of an LPLi injector, then the effects of butane and propane mixing rates on ice formation at the intake port and nozzle tip was investigated. As a result, the icing characteristics of them showed contrary results according to the mixing rates.

Application of Light Collecting Probe with High Spatial Resolution to Spark-Ignited Spherical Spray Flames

  • Yang, Young-Joon;Akamatsu, Fumiteru;Katsuki, Masashi
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.2058-2065
    • /
    • 2004
  • A light collecting probe named Multi-color Integrated Cassegrain Receiving Optics (MICRO) is applied to spark-ignited spherical spray flames to obtain the flame propagation speed in freely falling droplet suspension produced by an ultrasonic atomizer. Two MICRO probes are used to monitor time-series signals of OH chemiluminescence from two different locations in the flame. By detecting the arrival time difference of the propagating flame front, the flame propagation speed is calculated with a two-point delay-time method. In addition, time-series images of OH chemiluminescence are simultaneously obtained by a high-speed digital CCD camera to ensure the validity of the two-point delay-time method by the MICRO system. Furthermore, the relationship between the spray properties measured by phase Doppler anemometer (PDA) and the flame propagation speed are discussed with three different experimental conditions by changing the fuel injection rate. It was confirmed that the two-point delay-time method with two MICRO probes is useful and convenient to obtain the flame propagation speed and that the flame propagation speed depends on the spray properties.