다중 PCB 적층 모듈구조의 정보통신용 캐비넷 강제대류 냉각특성 연구 (Forced Convective Cooling Characteristics with Stacked Modules of Multi-PCBs' in Telecommunication Cabinet)

  • 김원태;김광수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.230-239
    • /
    • 1996
  • A multi-faceted experimental investigation has been carried out to study the cooling performance for stacked modules in arrays of heat generating rectangular modules deployed along PCB's in the enclosed cabinet. The main parameters which have an important effect on cooling characteristics are flow velocity, channel spacing, installation of fan unit, attachment of heat sink, and acoustic noise. The results of individual effect are very helpful for the electronic packaging designer. In order to improve the cooling performance, it is certain that the enlargement of channel space is obviously effective, while this id disadvantageous in high density electronic packaging. Each of the paameters is quantitatively examined as cooling performance and the correlation of Reynolds number to Nusselt number is compared with previous study.

  • PDF

PIV 유동 계측을 통한 자동차 프런트 엔드 쿨링 팩 시스템의 외부 유동특성 평가 (PIV Analysis of the External Flow Field of Front End Cooling Pack System)

  • 허형석;한창평;박경석;이기수;배석정;원종필
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.103-110
    • /
    • 2004
  • The major trend in global automotive market is changing drastically in the way that a vehicle FECPS(Front End Cooling Pack System) is designed and manufactured as an assembly part. The system can encompass many functions, be assembled into a vehicle as a module, and reduce the production cost as well as time. The FECPS consists of an impact beam, an aluminum condenser and a radiator, a carrier and a cooling fan with a BLDC motor. In order to predict the performance of a FECPS accurately, it is essential to properly model the air flow field through various heat exchangers, such as a condenser or a radiator. In this study, the flow field of the system is measured by a PIV(Particle Image Velocimetry) system. The result is compared with that measured with multi-channel anemometer.

마이크로 채널 디자인에 따른 온 칩 액체 냉각 연구 (Study of On-chip Liquid Cooling in Relation to Micro-channel Design)

  • 원용현;김성동;김사라은경
    • 마이크로전자및패키징학회지
    • /
    • 제22권4호
    • /
    • pp.31-36
    • /
    • 2015
  • 전자소자의 다기능, 고밀도, 고성능, 그리고 소형화는 전자 패키지 기술에 초미세 피치 플립 칩, 3D 패키지, 유연 패키지, 등 새로운 기술 패러다임 전환을 가져왔으며, 이로 인해 패키지 된 칩의 열 관리는 소자의 성능을 좌우하는 중요한 요소로 대두되고 있다. Heat sink, heat spreader, TIM, 열전 냉각기, 등 많은 소자 냉각 방법들 중 본 연구에서는 냉매를 이용한 on-chip 액체 냉각 모듈을 Si 웨이퍼에 제작하고, 마이크로 채널 디자인에 따른 냉각 효과를 분석하였다. 마이크로 채널은 딥 반응성 이온 에칭을 이용하여 형성하였고, 3 종류 디자인(straight MC, serpentine MC, zigzag MC)으로 제작하여 마이크로 채널 디자인이 냉각 효율에 미치는 영향을 관찰하였다. 가열온도 $200^{\circ}C$, 냉매 유동속도 150 ml/min의 경우에서 straight MC가 약 $44^{\circ}C$의 높은 냉각 전후의 온도 차를 보였다. 냉매의 흐름과 상 변화는 형광현미경으로 관찰하였으며, 냉각 전후의 온도 차는 적외선현미경을 이용하여 분석하였다.

고해상도 LCD TV 용 DDI 방열 패키지 개발에 열해석 적용 (Applying Thermal Simulation to the DDI Development of Heat Dissipation Package for High Definition LCD-TV)

  • 정충효;유재욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2444-2448
    • /
    • 2007
  • The multi channel of DDI which is the core part of the LCD-TV has been propelled. When multi channel in DDI is introduced, it brings a thermal problem because of the increased power. To solve the thermal problem of the DDI it needs to be investigated each at the package level and module level. It is important to extract the junction temperature(Tj) of DDI clearly from the system level. The objective of this research is to construct a compact model. The compact model is to reduce LCD module including DDI. When the compact model is used, it will be able to easily handle the boundary condition and accurately predict the temperature. Consequently, the temperature of DDI can be calculated easily at the system level. Through this research,we also proposed the cooling plan of DDI for a protection of overheating. The cooling plan was utilized in DDI design.

  • PDF

적층형 Multi-Chip Module(MCM) 내부에 삽입된 초소형 열교환기 내에서의 대류 열전달 현상에 대한 연구 (A Study on the Convective Heat Transfer in Micro Heat Exchanger Embedded in Stacked Multi-Chip Modules)

  • 신중한;강문구;이우일
    • 대한기계학회논문집A
    • /
    • 제28권6호
    • /
    • pp.774-782
    • /
    • 2004
  • This article presents a numerical and experimental investigation for the single-phase forced laminar convective heat transfer through arrays of micro-channels in micro heat exchangers to be used for cooling power-intensive semiconductor packages, especially the stacked multi-chip modules. In the numerical analysis, a parametric study was carried out for the parameters affecting the efficiency of heat transfer in the flow of coolants through parallel rectangular micro-channels. In the experimental study, the cooling performance of the micro heat exchanger was tested on prototypes of stacked multi-chip modules with difference channel dimensions. The simulation results and the experiment data were acceptably accordant within a wide range of design variations, suggesting the numerical procedure as a useful method for designing the cooling mechanism in stacked multi-chip packages and similar electronic applications.

다채널 알루미늄 평판관내 R22와 R134a의 흐름 응축 열전달 성능 비교 (A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube)

  • 서영호;박기정;정동수
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.589-598
    • /
    • 2004
  • Flow condensation heat transfer coefficients (HTCs) of R22 and R134a were measured on a horizontal 9 hole aluminum multi-channel tube. The main test section in the refrigerant loop was made of a flat multi-channel aluminum tube of 1.4 mm hydraulic diameter and 0.53 m length. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in the vapor qualities of 0.1∼0.9 at mass flux of 200∼400 kg/$m^2$s and heat flux of 7.3∼7.7 ㎾/$m^2$ at the saturation temperature of 4$0^{\circ}C$. All popular correlations in single-phase subcooled liquid and flow condensation originally developed for large single tubes predicted the present data of the flat tube within 20% deviation when effective heat transfer area is used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Thermal insulation for the outer tube section surrounding the test tube for the transport of heat transfer fluid is very important in fluid heat-ing or cooling type heat transfer experimental apparatus.

금형 냉각이 Al-Mn계 다중압출 평판관의 압출 특성 변화에 미치는 영향 (Effects of die cooling on change of extrusion characteristics of Al-Mn-based thin-walled flat multi-port tube)

  • 신영철;하성호;강태훈;이기안;이승철
    • Design & Manufacturing
    • /
    • 제17권4호
    • /
    • pp.63-71
    • /
    • 2023
  • In order to increase the extrusion production speed of aluminum, extrusion die cooling technology using liquid nitrogen has recently attracted a lot of attention. Increasing the extrusion speed increases the temperature of the bearing area of extrusion dies and the extrusion profile, which may cause defects on the surface of extruded profile. Extrusion die cooling technology is to directly inject liquid nitrogen through a cooling channel formed between the die and the backer inside the die-set. The liquid nitrogen removes heat from the die-set, and gaseous nitrogen at the exit of the channel, covers the extrusion profile of an inert atmosphere reducing the oxidation and the profile temperature. The aim of this study is to evaluate the cooling capacity by applying die cooling to extrusion of Al-Mn-based aluminum alloy flat tubes, and to investigate the effects of die cooling on the change in extrusion characteristics of flat tubes. Cooling capacity was confirmed by observing the temperature change of the extrusion profile depending on whether or not die cooling is applied. To observe changes in material characteristics due to die cooling, surface observation is conducted and microstructure and precipitate analysis are performed by FE-SEM on the surface and longitudinal cross section of the extruded flat tubes.

NSGA-II를 통한 딤플채널의 다중목적함수 최적화 (Multi-Objective Optimization of a Dimpled Channel Using NSGA-II)

  • 이기돈;압두스 사마드;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.113-116
    • /
    • 2008
  • This work presents numerical optimization for design of staggered arrays of dimples printed on opposite surfaces of a cooling channel with a fast and elitist Non-Dominated Sorting of Genetic Algorithm (NSGA-II) of multi-objective optimization. As Pareto optimal front produces a set of optimal solutions, the trends of objective functions with design variables are predicted by hybrid multi-objective evolutionary algorithm. The problem is defined by three non-dimensional geometric design variables composed of dimpled channel height, dimple print diameter, dimple spacing and dimple depth to maximize heat transfer rate compromising with pressure drop. Twenty designs generated by Latin hypercube sampling were evaluated by Reynolds-averaged Navier-Stokes solver and the evaluated objectives were used to construct Pareto optimal front through hybrid multi-objective evolutionary algorithm. The optimum designs were grouped by k-mean clustering technique and some of the clustered points were evaluated by flow analysis. With increase in dimple depth, heat transfer rate increases and at the same time pressure drop also increases, while opposite behavior is obtained for the dimple spacing. The heat transfer performance is related to the vertical motion of the flow and the reattachment length in the dimple.

  • PDF

PCB회로 보드장치내의 안정적 방열설계를 위한 연구 (The stable design of radiant heat inside PCB circuit board device)

  • 원종운;이종휘
    • 대한안전경영과학회지
    • /
    • 제15권2호
    • /
    • pp.129-134
    • /
    • 2013
  • In this study, the heat flow analysis compatible commercial code CFX 11 was used to develop the structure inside PCB circuit board devices, which could stable radiant heat as well as the cooling device within it. In case of modifying the arrangement of electronic parts on the PCB inside the multi channel temperature measurement board devices, radiant heat effects did not show a rising tendency, whereas the overall temperature went down in case of installing the vents in the outer case of PCB circuit board devices. In terms of installation location, it was the most appropriate to install it on the electronic parts with no heat. Besides, in case of mounting the fan as a cooling device by considering various user environments for multi channel temperature measurement board devices, the radiant heat effects were shown higher than in case of installing the vents, and the middle sections were the most appropriate to its installation location. In case of changing the wind quantity of the fan from its selected installation location, the best radiant heat effects were shown at high speed as expected.