• Title/Summary/Keyword: Multi Compartment

Search Result 38, Processing Time 0.026 seconds

Approximate Optimization with Discrete Variables of Fire Resistance Design of A60 Class Bulkhead Penetration Piece Based on Multi-island Genetic Algorithm (다중 섬 유전자 알고리즘 기반 A60 급 격벽 관통 관의 방화설계에 대한 이산변수 근사최적화)

  • Park, Woo-Chang;Song, Chang Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.33-43
    • /
    • 2021
  • A60 class bulkhead penetration piece is a fire resistance system installed on a bulkhead compartment to protect lives and to prevent flame diffusion in a fire accident on a ship and offshore plant. This study focuses on the approximate optimization of the fire resistance design of the A60 class bulkhead penetration piece using a multi-island genetic algorithm. Transient heat transfer analysis was performed to evaluate the fire resistance design of the A60 class bulkhead penetration piece. For approximate optimization, the bulkhead penetration piece length, diameter, material type, and insulation density were considered discrete design variables; moreover, temperature, cost, and productivity were considered constraint functions. The approximate optimum design problem based on the meta-model was formulated by determining the discrete design variables by minimizing the weight of the A60 class bulkhead penetration piece subject to the constraint functions. The meta-models used for the approximate optimization were the Kriging model, response surface method, and radial basis function-based neural network. The results from the approximate optimization were compared to the actual results of the analysis to determine approximate accuracy. We conclude that the radial basis function-based neural network among the meta-models used in the approximate optimization generates the most accurate optimum design results for the fire resistance design of the A60 class bulkhead penetration piece.

Comparison of the Timber Harvesting Productivity and Cost of Single-operation using a Forestry Combi-machine Versus Multi-operation using a Tower-yarder and Processor (타워야더+프로세서 기반의 작업시스템에서 단공정 및 다공정작업의 생산성 및 비용분석)

  • Min-Jae, Cho;Yun-Sung, Choi;Ho-Seong, Mun;Jae-Heun, Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.4
    • /
    • pp.583-593
    • /
    • 2022
  • The harvesting system in South Korea faces the problems of aging workers and high wages, so it is necessary to improve the operation system and train workers to use high-performance forestry machines. This study compared the effectiveness and costs of yarding and processing operations between a multi-operation system using a tower yarder (HAM300) and a processor (KESLA 20SH) with those of a single-system using a forestry combi-machine. A whole-tree (cable) yarding operation was conducted in the clear-cutting area located at Compartment 15, Gwangneung Experimental Forest, National Institute of Forest Science, and the productivity and cost of multi- and single-system were analyzed. The productivity of the single-system was 1.5 m3/PMH and 1.6 m3/PMH higher than that of the multi- system because the single-system produced 1 log/cycle more than the multi-system in the yarding operation. The cost was approximately 12.1% lower for the single-system (₩36,113/m3) than for the multi-system (₩41,065/m3). The costs of the single-system and multi-system were decreased by maximums of 22.6% and 15.9%, respectively, by decreasing the idle time.

Multi-dimensional Fire Behaviors in an Under-ventilated Compartment Fire (환기부족 구획화재에서 다차원 화재거동)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.37-42
    • /
    • 2010
  • 실제 규모 ISO 9705 표준 화재실에서 과환기(over-ventilated) 및 환기부족(under-ventilated) 화재에 대한 열 및 화학적 특성에 관한 실험이 수행되었다. 또한 FDS(Fire Dynamic Simulator)를 이용하여 수치적 예측성능에 대한 평가와 환기부족화재에서 건물 내부의 다차원 화재현상에 대한 해석이 이루어졌다. 과환기 및 환기부족화재의 특성은 연소효율, 총괄 당량비 뿐만 아니라 고온 상층부의 온도분포, 연소 생성물의 농도에 의해 명확하게 구분되었다. 실험결과와의 비교를 통해 과환기 및 환기부족화재에서 FDS는 공간내부의 온도, 열유속 및 다양한 화학종의 분포를 정량적으로 잘 예측함을 확인하였다. 과환기화재와 비교할 때, 환기부족화재에서 내부유동은 반대방향의 다차원 재순환 유동구조를 갖고 있음을 발견하였다. 동시에 공간내부의 $O_2$ 및 CO의 분포 역시 다차원 구조를 갖기 때문에 기존화재연구에서 측정되는 고온 상층부의 열 및 화학적 특성은 환기부족화재를 이해하는데 많은 한계가 있음을 확인하였다.

  • PDF

Multi-Level Anterior Interbody Fusion with Internal Fixation in Cervical Spine (다분절 경추 유합 및 내고정 수술결과)

  • Jeon, Woo-Youl;Bae, Jang-Ho;Jung, Byoung-Woo;Kim, Seong-Ho;Kim, Oh-Lyong;Choi, Byung-Yon;Cho, Soo-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.55-60
    • /
    • 2001
  • Objective : The purpose of the present study was to examine neurologic changes, fusion rate and degree of kyphosis from the surgical results of those patients who underwent multi-level anterior interbody fusion and internal fixation. Methods : Among 63 cases of the patients who received multi-level anterior interbody fusion and internal fixation in 5 years between 1995 to 1999 at the neurosurgery department, we performed a retrospective study in 52 cases that could be followed up with dynamic view imaging ; the results were compared and analyzed. The analysis was based on the results of history taking, physical findings and radiologic findings, and Odom criteria were used to classify those cases with neurologic changes. Results : Among those 52 cases in whom the follow-up was possible for at least a year and dynamic view imaging was possible, bone fusion was seen in 93% of the trauma cases and 95% in the non-trauma cases and overall bone fusion was observed in 94% of the cases. Bone fusion was seen in 93% of the autobone cases, 95% of the allobone cases, and 94% of the Mesh cases. Radiologic changes were observed by comparing the lateral view after surgery ; kyphosis was seen in 53% of the autobone cases, in 70% of the allobone cases, and in 35% of Mesh cases ; in 45% and 60% of the non-trauma cases and trauma cases, respectively ; and in 55% of the 2 level fusion cases and 46% of the 3 level fusion cases. Neurologic changes classified according to Odom criteria showed excellent result in 48% of all the cases, good in 23%, fair in 4%, and poor in 25%. Conclusion : Even those cases with multi-level fusion, a high fusion rate could be obtained by performing anterior interbody fusion and internal fixation ; those cases with kyphosis were related more with the presence or absence of posterior compartment injury rather than the fusion level ; and those trauma cases showed not much difference in the fusion rate compared with non-trauma cases but had a high possibility of kyphosis.

  • PDF

Temporal Characteristics of Selected Volatile Organic Compounds in Urban High-Stories Urban Apartments

  • Shin, Seung Ho;Kim, Ji-Hoon;Jo, Wan Kuen
    • Journal of Environmental Science International
    • /
    • v.24 no.10
    • /
    • pp.1273-1283
    • /
    • 2015
  • In present study, the temporal characteristics of nine selected volatile organic compounds (VOCs), including four alcohol, 2 aldehyde, and 3 ketone compounds, in high-stories urban apartments over a 2-y period were investigated. The indoor VOC concentrations had generally a decreasing trend over the 2-y follow-up period. For examples, the 2E1H indoor concentration decreased from $10.8{\mu}g/m^3$ for the first two months to $5.1{\mu}g/m^3$ for the last two months. In addition, the DCA and ACT indoor concentrations decreased from 5.0 and $14{\mu}g/m^3$ for the first two months to 2.2 and $6.4{\mu}g/m^3$, respectively, for the last two months. The indoor-to outdoor concentration ratios over the 2-y period were much greater than 1, indicating that indoor VOC concentrations were higher than the outdoor VOC concentrations. Similar to those of the individual VOCs, the indoor-to-outdoor concentration ratios of all three VOC groups were higher than 1 over the 2-y follow-up period, suggesting higher indoor concentrations of the three VOC groups than outdoor concentrations. In consistence with the results of VOC indoor concentrations, the VOC emission rates decreased gradually as time passed, due to the decreased VOC emission strengths of indoor sources. Finally, there was an initial sharp decrease in the indoor VOC concentrations followed by a slower decrease, indicating a multi-exponential decay model for the target VOCs, which was demonstrated by comparison of the residuals and the adjusted coefficient of determination associated with the one and two-exponential fits of each data set.

Design/Construction and Performance Test of Hypersonic Shock Tunnel Part Ⅰ: Design Method of Hypersonic Shock Tunnel (극초음속 충격파 풍동 설계/구축 및 성능시험 Part Ⅰ: 극초음속 충격파 풍동 설계 방법)

  • Lee, Bok-Jik;Lee, Hyoung-Jin;Kim, Sei-Hwan;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.321-327
    • /
    • 2008
  • The shock tunnel as a hypersonic ground test facility was designed, constructed and its performance test was conducted to reproduce the high speed flow which the hypersonic propulsion system is encountered. The design points were understood and the conceptual design was completed using the quasi one dimensional operation analysis code. After that, the specific performance and compartment design were completed using CFD simulation as the part analysis. The facility was then constructed according to those design results and the performance test was conducted for various operation conditions. In this paper, we suggested the design method of hypersonic shock tunnel including the conceptual and performance design using theoretical analysis and the quasi 1D Multi-species computational fluid dynamics code.

Cerebrospinal Fluid Profiles and Their Changes after Intraventricular Chemotherapy as Prognostic or Predictive Markers for Patients with Leptomeningeal Carcinomatosis

  • Kwon, Ji-Woong;Shim, Youngbo;Gwak, Ho-Shin;Park, Eun Young;Joo, Jungnam;Yoo, Heon;Shin, Sang-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.631-643
    • /
    • 2021
  • Objective : Here, we evaluated whether cerebrospinal fluid (CSF) profiles and their changes after intraventricular chemotherapy for leptomeningeal carcinomatosis (LMC) could predict the treatment response or be prognostic for patient overall survival (OS) along with clinical factors. Methods : Paired 1) pretreatment lumbar, 2) pretreatment ventricular, and 3) posttreatment ventricular samples and their CSF profiles were collected retrospectively from 148 LMC patients who received Ommaya reservoir installation and intraventricular chemotherapy. CSF profile changes were assessed by calculating the differences between posttreatment and pretreatment samples from the same ventricular compartment. CSF cell counts were further differentiated into total and other based on clinical laboratory reports. Results : For the treatment response, a decreased CSF 'total' cell count tended to be associated with a 'controlled' increase in intracranial pressure (ICP) (p=0.059), but other profile changes were not associated with either the control of increased ICP or the cytology response. Among the pretreatment CSF profiles, lumbar protein level and ventricular cell count were significantly correlated with OS in univariable analysis, but they were not significant in multi-variable analysis. Among CSF profile changes, a decrease in 'other' cell count showed worse OS than 'no change' or increased groups (p=0.001). The cytological response was significant for OS, but the hazard ratio of partial remission was paradoxically higher than that of 'no response'. Conclusion : A decrease in other cell count of CSF after intraventricular chemotherapy was associated with poor OS in LMC patients. We suggest that more specific CSF biomarkers of cancer cell origin are needed.

Surrogate Models and Genetic Algorithm Application to Approximate Optimization of Discrete Design for A60 Class Deck Penetration Piece (A60 급 갑판 관통 관의 이산설계 근사최적화를 위한 대리모델과 유전자 알고리즘 응용)

  • Park, Woo Chang;Song, Chang Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.377-386
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistant system installed on a horizontal compartment to prevent flame spreading and protect lives in fire accidents in ships and offshore plants. This study deals with approximate optimization using discrete variables for the fire resistance design of an A60 class deck penetration piece using different surrogate models and a genetic algorithm. Transient heat transfer analysis was performed to evaluate the fire resistance design of the A60 class deck penetration piece. For the approximate optimization of the piece, the length, diameter, material type, and insulation density were applied to discrete design variables, and temperature, productivity, and cost constraints were considered. The approximate optimum design problem based on the surrogate models was formulated such that the discrete design variables were determined by minimizing the weight of the piece subjected to the constraints. The surrogate models used in the approximate optimization were the response surface model, Kriging model, and radial basis function-based neural network. The approximate optimization results were compared with the actual analysis results in terms of approximate accuracy. The radial basis function-based neural network showed the most accurate optimum design results for the fire resistance design of the A60 class deck penetration piece.