• Title/Summary/Keyword: Moving Electrode

Search Result 86, Processing Time 0.028 seconds

A study of decomposition of sulfur oxides(harmful gas) using calcium dihydroxide catalyst by plasma reactions (Ca(OH)2촉매를 이용한 플라즈마 반응에 의한 황산화물(유해가스)의 제거에 관한 연구)

  • Kim, Dayoung;Hwang, Myungwhan;Woo, Insung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.237-246
    • /
    • 2014
  • Researches on the elimination of sulfur and nitrogen oxides with catalysts and absorbents reported many problems related with elimination efficiency and complex devices. In this study, decomposition efficiency of harmful gases was investigated. It was found that the efficiency rate can be increased by moving the harmful gases together with SPCP reactor and the catalysis reactor. Calcium hydroxide($Ca(OH)_2$), CaO, and $TiO_2$ were used as catalysts. Harmful air polluting gases such as $SO_2$ were measured for the analysis of decomposition efficiency, power consumption, and voltage according to changes to the process variables including frequency, concentration, electrode material, thickness of electrode, number of electrode winding, and additives to obtain optimal process conditions and the highest decomposition efficiency. The standard sample was sulfur oxide($SO_2$). Harmful gases were eliminated by moving them through the plasma generated in the SPCP reactor and the $Ca(OH)_2$ catalysis reactor. The elimination rate and products were analyzed with the gas analyzer (Ecom-AC,Germany), FT-IR(Nicolet, Magna-IR560), and GC-(Shimazu). The results of the experiment conducted to decompose and eliminate the harmful gas $SO_2$ with the $Ca(OH)_2$ catalysis reactor and SPCP reactor show 96% decomposition efficiency at the frequency of 10 kHz. The conductivity of the standard gas increased at the frequencies higher than 20 kHz. There was a partial flow of current along the surface. As a result, the decomposition efficiency decreased. The decomposition efficiency of harmful gas $SO_2$ by the $Ca(OH)_2$ catalysis reactor and SPCP reactor was 96.0% under 300 ppm concentration, 10 kHz frequency, and decomposition power of 20 W. It was 4% higher than the application of the SPCP reactor alone. The highest decomposition efficiency, 98.0% was achieved at the concentration of 100 ppm.

ITO Patterning of an In-line Wet Etch/Cleaning System by using a Reverse Moving Control System (반송제어모드를 이용한 인라인 식각/세정장치의 ITO 전극형성기술)

  • Hong, Sung-Jae;Im, Seoung-Hyeok;Han, Hyung-Seok;Kwon, Sang-Jik;Cho, Eou-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.327-331
    • /
    • 2008
  • An in-line wet etch/cleaning system was established for the research and development in wet etch process as a formation of electrode such as metal or transparent conductive oxide layer. A reverse moving system was equipped in the in-line wet etch/cleaning system for the alternating motion of glass substrate in a wet etch bath of the system. Therefore, it was possible for the glass substrate to be moved back and forth and it was possible to reduce the size of the system by using the reversing moving system. For the effect of the alternating motion of substrate on the etch rate in the in-line wet etch bath, indium tin oxide(ITO) patterns were obtained through wet etch process in the in-line system in which the substrate was moved back and forth. From the CD(critical dimension) skews resulted from the ADI CD and ACI CD of the ITO patterns, it was concluded that the alternating motion of glass substrate are possible to be applied to the mass production of wet etch process.

The Assessment of Dynamic Mental Stress with Wearable Heart Activity Monitoring System (착용형 심장활동 모니터링 시스템을 활용한 정신적 스트레스 평가)

  • Kim, Kyeong-Seop;Shin, Seung-Won;Lee, Jeong-Whan;Choi, Hee-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1109-1115
    • /
    • 2008
  • In the ubiquitous health monitoring environments, it is quite important not only to evaluate the physiological health condition but also mental stress condition. In order to achieve this goal, a heart activity monitoring system utilizing a wearable bipolar electrode is devised and the heart rate variability(HRV) is extracted and interpreted in both frequency and time feature domains. Consequently, to evaluate the emotional stress condition of the subjects, a stress-induced experimental protocol was applied to healthy subjects and the time and frequency features of heart activity were analyzed in terms of the ratio of low frequency components v.s., high frequency components and the relevant the moving average distributions compromising the successive RR peaks intervals in the ambulatory ECG measurement system.

Effect of Radius of Curvature of a Corona Needle on Ionic Wind Generation (방전 침전극의 곡률반경이 이온풍 발생에 미치는 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.604-608
    • /
    • 2010
  • An electric fan for cooling high density electronic devices is limited and operated in very low efficiency. The corona discharge is utilized as the driving mechanism for an ionic gas pump, which allows for air flow control and generation with low noise and no moving parts. These ideal characteristics of ionic pump give rise to variety applications. However, all of these applications would benefit from maximizing the flow velocities and yields of the ionic pump. In this study, a needle-mesh type ionic pump has been investigated by focusing on the radius of curvature of corona needle points elevating the ionic wind velocity and efficiency. It is found that the radius of curvature of the corona discharge needle point influences significantly to produce the ionic wind and efficiency. As a result, an elevated ionic wind velocity and increased ionic wind generation yield can be obtained by optimized the radius of curvature of the corona needle electrode.

Characteristics of efficiency by using the combined electrostatic precipitator (조합형 전기집진기를 이용한 집진효율 특성)

  • 김용진;정상현;홍원석;황태근;옥영욱;김두현;하병길;함병훈
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.242-243
    • /
    • 1999
  • 전기집진기는 산업 분진 및 폐가스 집진을 위해 널리 이용되며, 고전기 저항 분진에 의한 집진극 표면의 역전리가 전기집진기에서 가장 큰 문제이다. 이런 역전리 현상을 방지하기 위해 가스온도 제어, 가스조건, 하전 제어 등 다양한 방법이 시도되고 있다. 전기집진기에서 고 비저항 분진 및 역전리의 영향으로부터 높은 집진효율을 얻기 위한 방법 중 하나로 이동 전극형 방식(Moving Electrode Electrostatic precipitator, MEEP)과 고정전극형 (Fixed Electrode Electrostatic precipitatior, FEEP)에 펄스하전 방식으로 구성된 조합형 전기집진기가 개발되고 있다.(Toshiaki Misaka etc. 1996)(중략)

  • PDF

A Study on the Enhancement of Emission Efficiency of an Organic EL Devices Using the RF Plasma (RF 플라즈마를 이용한 유기 EL소자의 발광 효율에 관한 연구)

  • 박상무;김형권;신백균;임경범;이덕출
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.400-406
    • /
    • 2003
  • Efficient electrodes are devised for organic luminescent device(OLED). ITO electrode is treated with $O_2$ plasma. In order to inject hole efficiently, there is proposed the shape of anode that inserted plasma polymerized films as buffer layer between anode and organic layer using thiophene monomer. In the case of device inserted the buffer layer by using the plasma polymerization after $O_2$ plasma processing for ITO transparent electrode, since it forms the stable interface and reduce the moving speed of hole, the recombination of hole and electronic are made in the emitting layer. Therefore it realized the device capability of two times in the aspect of luminous efficiency than the device which do not be inserted the buffer layer. Experiments are limited to the device that has the structure of TPD/$AIq_3$, however, the aforementioned electrodes can similarly applied to the organic luminous device and the Polymer luminous device.

Effect of the Electric Field on the Plant Protoplasts During Cell Fusion (세포융합시 전계하에서 식물세포가 받는 영향에 관한연구)

  • Lee, Sang-Hoon;Lee, Yon-Min;Cha, Hyeon-Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 1996
  • The objective of this paper is to investigate the effect of AC field on the protoplast of plant cells. The results of investigation will be the basis for the development of etectric cell fusion device. For the experiment, we made the electrode and AC and DC pulse generator and observed the behavior of the protoplasts through the inverted microscope which is connected to the monitor and video recorder by the CCD camera. As a result, the numbers of rotating, moving and destructed protoplasts and viability of the protoplasts have close relation to the amplitude of AC field, while the rotation rate is closely related to the frequency of AC pulse.

  • PDF

Effect of Ultrasonic Vibration on Micro-EDM Channel (Micro-EDM 채널가공에서 초음파 가진의 영향)

  • Lim, Heesung;Hong, Minsung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.421-425
    • /
    • 2016
  • Micro-EDM is one of the recent fine-machining technologies. Micro-EDM is widely used in precision processes because products manufactured via EDM are free from workpiece hardness. However, the debris produced during the process cause many problems such as reduced precision of the process. The first solution of this problem involves using the milling hole process. Micro-EDM hole process involves an electrode moving rapidly in the vertical direction via a servo system to disperse debris. However, this process can cause reduced work efficiency owing to contact between the electrode and workpiece. In this study, ultrasonic vibration is added to micro-EDM channel machining. Ultrasonic vibration removes the debris during machining and enables precision machining. Consequently, a clean work environment for the subsequent processes is maintained.

A Study on New Inverse Pinch Switch for High Power Transfer (High Power 전달을 위한 새로운 Inverse Pinch Switch에 관한 연구)

  • Cho, Kook-Hee;Kim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.120-125
    • /
    • 2006
  • In contrast to the conventional trigatron switch in which the currents are constricted by the z-pinch mechanical the new switch operates in an inverse pinch geometry formed by a pair of spiral electrodes in a sealed-off type. Inverse pinch switch greatly reduces hot spot formations and protects the electrode surfaces. The switch can be initiated with an electrical trigger electrode. Advantages of the new switch over the conventional switches are longer useful life, high current capability and lower inductance due to the dispersed and moving current sheet. These improved characteristics may make the inverse pinch switch suitable for pulse power systems.

Research on the Electrical Charging of a Water Droplet on the Electrode and Droplet Actuation Method using Electrical Charge (전극표면에서 액적의 충전현상과 이를 이용한 액적의 이동 방법에 관한 연구)

  • Jung, Yong-Mi;Oh, Hyung-Chang;Kang, In-Seok
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.666-669
    • /
    • 2008
  • Droplet in miniaturized microfluidic systems have received much focused attention recently. In this work, electrical charging phenomenon of a conducting water droplet on the electrode under the dc electric field is studied and using this phenomenon droplet actuation method for microreactor applications is experimentally demonstrated. To find effects of key factors, the effects of electric field, medium viscosity, and droplet size are investigated. A scaling law of charging for the conducting droplet is derived from the experimental results. Unlike the case of a perfect conductor, the estimated amount of electrical charge ($Q_{est}$) of a water droplet is proportional to the 1.59 power of the droplet radius (R) and the 1.33 power of the electric field strength (E). (For a spherical perfect conductor, Q is proportional to R2 and E.) It is thought that the differences are mainly due to incomplete charging of a water droplet resulted from the combined effect of electrochemical reaction at electrode and the relatively low conductivity of water. Using this phenomenon, we demonstrate the transport of the charged droplet and fusion of two oppositely-charged droplets. When electric field is subjected sequentially on the electrode, the charged droplet is transported on the electrode. For the visualization of fusion of charged droplets, the precipitation reaction is used. When subjected to a DC voltage, two droplets charged are moving and merging toward each other due to the Coulombic force and chemical reaction is simultaneously occurred by coalescence of droplets. It may be due to the interchange effect of charge. It is shown that the droplet can be used for microreactor where transporting, merging etc. of reagents constitute unit operation.

  • PDF