• Title/Summary/Keyword: Movement plane

Search Result 379, Processing Time 0.028 seconds

Coordinated Intra-Limb Relationships and Control in Gait Development Via the Angle-Angle Diagram (보행 시 연령에 따른 하지 관절 내 운동학적 협응과 제어)

  • Lee, Kyung-Ok
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.17-35
    • /
    • 2004
  • The purpose of this study is to explain developmental process of gait via angle-angle diagram to understand how coordinated relationships and control change with age. Twenty four female children, from one to five years of age were the test subjects for this study, and their results were compared to a control group consisting of twenty one adult females. The Vicon 370 CCD camera, VCR, video timer, monitor, and audio visual mixer was utilized to graph the gait cycle for all test subjects. Both coordinated Intra-limb relationships, and range of motion and timing according to quadrant were explained through the angle angle diagram. Movement in the sagittal plane showed both coordinated relationships and control earlier than movement in the coronal or transverse plane. In the sagittal plane, hip and Knee coordinated relationships developed first (from one year of age.) Coordinated relationships in the Knee and ankle and hip and ankle developed next, respectively. Both hip and ankle and knee and ankle development were inhibited by the inability of children to completely perform plantar flexion during the swing and initial double limb support phases. Children appeared to compensate for this by extending at their hip joint more than adults during the third phase, final double limb support. In many cases the angle angle diagram for children had a similar shape as adult's angle angle diagram. This shows that children can coordinate their movements at an early age. However, the magnitudes and timing of children's angle angle diagrams still varied greatly from adults, even at five years of age. This indicates that even at this age, children still do not possess full control of their movements.

Design of a Force Applying System for a Smart-phone Curved Glass Molding System and Its Characteristic Test (스마트폰 곡면유리 성형시스템의 가압장치 설계 및 곡면유리 성형특성실험)

  • Kim, Hyeon-Min;Hong, Tae-Kyung;Jung, Dong-Yean;Lee, Yeon-Hyeong;Park, Jea-Hyun;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.570-577
    • /
    • 2014
  • This paper describes the design of a force applying system for a smart phone curved glass molding system and its characteristic test. The force applying system is composed of a motor and gear, a rectilinear movement structure, a force sensor, an LVDT (Linear Variable Differential Transformer) sensor, an up and down moving block, and so on. The system precisely controls the applying force and time to the plane glass because the glass can be easily destroyed under applied force, and can be bent imperfectly. As a result of the characteristic test, the curved glass can be manufactured using this system, and the holding time under 0N force, the applying force to the plane glass, the time for applying from 0N to maximum force, and the holding time under maximum force at the manufacture feasible temperature $620^{\circ}C$ were found.

An Experimental Study of Smoke Movement of the Various Fire Location in Room (실내공간에서 화재 발생위치에 따른 연기거동에 대한 실험연구)

  • Yu, Hong-Seon;Jeong, Jin-Yong;Lee, Jae-Ha;Hong, Gi-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.703-709
    • /
    • 2002
  • In order to investigate the smoke movement in three dimensional room fires, the center fire, wall fire and corner fire plume in different sized fires were studied experimentally by rectangular pool fire using methanol as a fuel. As the fire size became larger for the center fires placed at the center of the floor, the air flow rate entrained through the opening, average hot layer temperature, flame angle deflected backwards and mean flame height was observed to increase. On the other hand, as the fire size became smaller, the neutral plane height in the door and time reached steady-state was observed to decrease. The average hot layer temperature, mean flame height and doorway neutral plane height obtained from comer fire were higher than those produced by wall fires and center fires. The simple model for describing the effect of walls on the mean flame height was presented. It was shown that the model provides a good description of the present measurements, when used with the assumption by Hansell(1993), that the increase of the average flame height is equal to the ratio of the open to the total perimeters of the trays. Also the two models for predicting the effects of walls on the mean flame height were presented. These models overestimated the measured values of the mean flame height above fuel trays close to a wall and in a corner by approximately 19-26%, respectively.

Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer (디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석)

  • Chang, Woo-Nam;Lee, Kyoung-Bo;Yeom, Jun-Woo;Hwang, Byong-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

Optimum Blind Control at the End of Operation Time Zone for Preventing Glare on Work-plane and Maximizing Daylight and Solar Heat Gain (작업면 현휘 방지와 주광 및 일사 유입 최대화를 위한 제어 종료 영역에서의 최적 블라인드 제어)

  • Seong, Yoon-Bok;Yeo, Myoung-Souk;Koo, So-Young;Kim, Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.27-41
    • /
    • 2012
  • The objective of this study is to develop the blind control strategy and method which reduce negative effect of incoming daylight on visual comfort of occupants, minimize psychological anxieties caused by frequent motions of a blind, and maximize positive effect of incoming daylight and solar irradiation by opening/closing of a blind. As previous researches on blind controls have limited outdoor environmental conditions to those in specific regions, orientations and dates, these resulted in problems at various conditions for general-purpose application. Major problem is that the time interval and amount of blind movement do not meet the control objective at the end of control zone and discontinuous curve. To overcome these limitations revealed in the previous researches, following tasks were performed in this study. 1) To establish the control objective to accomplish the goal of this study. 2) To develop the control methods and algorithms which prevent glare on the work-plane at any time and which control the time interval and amount of blind movement to follow the control objective at various profile angle curves. 3) To validate the general-purpose applicability and performance of the developed control methods and algorithms by simulation and its data analysis at various conditions. It was found that the proposed methods and algorithms can prevent the direct glare on the work-plane at all the time and also increase the incoming daylight and solar irradiation.

A study of upper airway dimensional change according to maxillary superior movement after orthognathic surgery (양악 수술 시 상악골 상방 이동에 따른 상기도 변화)

  • Kim, Yong-Il;Park, Soo-Byung;Kim, Jong-Ryoul
    • The korean journal of orthodontics
    • /
    • v.38 no.2
    • /
    • pp.121-132
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the upper airway dimensional change according to maxillary superior movement after orthognathic surgery and to identify the relationship between the amount of maxillary movement and upper airway dimensional changes. Methods: The samples consisted of 24 adult patients (9 males and 15 females) who had a skeletal discrepancy and had received presurgical orthodontic treatment. They underwent Le Fort I superior impaction osteotomy and mandibular setback surgery. Cephalometric x-rays were taken at 3 stages - T0 (before orthognathic surgery), T1 (just or within 2 weeks after orthognathic surgery), T2 (6 months after surgery) Results: 1, Pharyngeal airway space (PAS (R)-nasopharynx) was decreased after surgery (T1) but recovered at 6 months after surgery; 2, Pharyngeal airway space (PAS (NL)-palatal plane) was increased after surgery and at 6 months after surgery; 3, Pharyngeal airway space (PAS (OL)-occlusal plane) was increased at T1 and was decreased at T2; 4, Soft palate thickness was increased at T1 but it became the same or thinner at T2; 5, There is no statistically significant relation between the amount of maxillary superior movement and pharyngeal airway space. Conclusions: These findings suggested that the maxillary superior movement of about an average of $4.40{\pm}1.14 mm$ did not affect upper pharyngeal airway space changes.

Evaluation of Accuracy and Inaccuracy of Depth Sensor based Kinect System for Motion Analysis in Specific Rotational Movement for Balance Rehabilitation Training (균형 재활 훈련을 위한 특정 회전 움직임에서 피검자 동작 분석을 위한 깊이 센서 기반 키넥트 시스템의 정확성 및 부정확성 평가)

  • Kim, ChoongYeon;Jung, HoHyun;Jeon, Seong-Cheol;Jang, Kyung Bae;Chun, Keyoung Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.228-234
    • /
    • 2015
  • The balance ability significantly decreased in the elderly because of deterioration of the neural musculature regulatory mechanisms. Several studies have investigated methods of improving balance ability using real-time systems, but it is limited by the expensive test equipment and specialized resources. Recently, Kinect system based on depth data has been applied to address these limitations. Little information about accuracy/inaccuracy of Kinect system is, however, available, particular in motion analysis for evaluation of effectiveness in rehabilitation training. Therefore, the aim of the current study was to evaluate accuracy/inaccuracy of Kinect system in specific rotational movement for balance rehabilitation training. Six healthy male adults with no musculoskeletal disorder were selected to participate in the experiment. Movements of the participants were induced by controlling the base plane of the balance training equipment in directions of AP (anterior-posterior), ML (medial-lateral), right and left diagonal direction. The dynamic motions of the subjects were measured using two Kinect depth sensor systems and a three-dimensional motion capture system with eight infrared cameras for comparative evaluation. The results of the error rate for hip and knee joint alteration of Kinect system comparison with infrared camera based motion capture system occurred smaller values in the ML direction (Hip joint: 10.9~57.3%, Knee joint: 26.0~74.8%). Therefore, the accuracy of Kinect system for measuring balance rehabilitation traning could improve by using adapted algorithm which is based on hip joint movement in medial-lateral direction.

A CASE REPORT ABOUT CORRECTION OF IMPLANT POSITION AT HORIZONTAL PLANE AFTER CORTICOTOMY (피질골 절단술을 이용한 수평면에서의 임플란트의 위치 교정에 대한 치험례)

  • Choi, Bin;Oh, Hae-Soo;Kim, Jin-Chul;Kil, Yong-Gab;Kim, Kyoung-Soo;Kim, Jwa-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Preface: Dental implant is important method that may solve the mastication, occlusion, esthetic, temporomandibular joint, and psychologic problem in oral and maxillofacial surgery. It is ideal that all of the implant are well positioned by adequate technique. By the way it‘s not always possible because of some anatomic, physiologic factor. In this case, If the implant can be moved to adequate position, it may be possible more esthetically and implanted patients more satisfied, but the majority of Implantists and orthodontists have thought that it is not possible. However, Implant, in fact, can be moved. and thus we can overcome the limit of implantation more. The aim of the present study was to evaluate the possibility of implant movement after corticotomy. Case report: Patient missed the upper right first molar. and implantation was done after completion of socket healing. We wait six months for osseointegration. Then, corticotomy was done under local anesthesia and close coil was used for orthodontic force. After traction during 3 weeks, we find the change of implant position at horizontal plane. we can not see the degenerative change on adjacent structure and tracted implant. there is a clinical mobility on upper right second premolar that used for anchorage but it subside spontaneously at the timing of prosthetic restoration without additional treatment. Discussion: As we could have some knowledge with this experiment, we report the case of implant movement after corticotomy and suggest a method about more esthetic implant treatment with a review of literature.

Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches

  • Miresmaeili, Amirfarhang;Sajedi, Ahmad;Moghimbeigi, Abbas;Farhadian, Nasrin
    • The korean journal of orthodontics
    • /
    • v.45 no.5
    • /
    • pp.236-244
    • /
    • 2015
  • Objective: The aim of this study was to investigate three-dimensional molar displacement after distalization via miniscrews and a horizontal modification of the trans-palatal-arch (TPA). Methods: The subjects in this clinical trial were 26 Class II patients. After the preparation of a complete set of diagnostic records, miniscrews were inserted between the maxillary 2nd premolar and 1st molar on the palatal side. Elastic modules connected to the TPA exerting an average force of 150-200 g/side parallel to the occlusal plane were applied. Cone-beam computed tomography was utilized to evaluate the position of the miniscrews relative to the adjacent teeth and maxillary sinus, and the direction of force relative to molar furcation. The distances from the central point of the incisive papilla to the mesiopalatal cusps of the 1st maxillary molars and the distances between the mesiopalatal cusps of the left and right molars were measured to evaluate displacement of the maxillary molars on the horizontal plane. Interocclusal space was used to evaluate vertical changes. Results: Mean maxillary 1st molar distalization was $2.3{\pm}1.1mm$, at a rate of $0.4{\pm}0.2mm/month$, and rotation was not significant. Intermolar width increased by $2.9{\pm}1.8mm$. Molars were intruded relative to the neighboring teeth, from 0.1 to 0.8 mm. Conclusions: Distalization of molars was possible without extrusion, using the appliance investigated. The intrusive component of force reduced the rate of distal movement.

A Study on the Inner Space of Frank Lloyd Wright's Early Houses(1900-1910) Characterized by the Movement of American Housing Development - Focused on American Art & Crafts Movement - (전환기 미국 주택개선운동의 수용에 따른 Frank Lloyd Wright의 초기주택(1900-1910) 내부 공간 특성에 관한 연구 - 미국 수공예 운동을 중심으로 -)

  • 견진현;양재혁
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.108-115
    • /
    • 2003
  • Between 1890-1914, the fundamental changes of the housing in United Sates of America were provoked to attempt the housing developments to adapt modern social system. The worthy of notice is that F L. Wright's Prairie House had been tested and built during the period as 'the first and second era' Despite the transition period in America, this represents that Wright's Prairie House series were developed. There are possibilities that some of the reformers assertion for Housing Development, on behalf of Arts & Crafts Movement, led to Wright's early house inner space design. For this reason, this study is to examine Ideologies that Wright has been accepted between the turning point of America's Arts & Crafts Movement and Hull House Circle. In terms of the ideologies acceptance, the study is also to examine how to be represented his inner space design characteristics. As the result, between'Simplification'housing development and the traditional housing In America, F L. Wright sublimated his own architectural aesthetic as accepting all functional elements to consider inevitability in this period, such as the association between economical and rational space, the plan to led on free plane, the spatial side and the stability of family life and the community, through the unification space having the consecutiveness.