• Title/Summary/Keyword: Movement plane

Search Result 379, Processing Time 0.031 seconds

Analysis of Kinematic Parameters of Gait in Normal Subject (정상 성인의 운동 형상학적 보행 분석)

  • Jung, Hwa-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2989-2995
    • /
    • 2014
  • This study was to performed to get the reference data of the kinematic parameters for normal subjects according to the arm movement type. Forty-five normal subjects participated in this study and preformed four sequence according to the arm movement type : normal arm movement, one arm movement, no arm movement, fitness arm movement. The study data was collected from June to August 2010. The kinematic data were measured using Vicon motion system 6MX3 cameras while each subjects walked through a 10m walkway. There were significant differences according arm movement type in the kinematic parameters such as range of motion (ROM) of the right pelvic, hip in sagittal plane, and ROM of the pelvic, hip, lumbar in coronal plane and ROM of the pelvic, thoracic, lumbar in transverse plane. This study can be utilized as the basic reference data in gait analysis for patients with pathologic gaits.

Effects of Occlusal Appliance on the Mandibular Position and the Mandibular Rotational Torque Movement during Speech (교합장치가 발음시 하악위 및 하악의 비틀림 회전운동에 미치는 영향)

  • Kim, Moon-Gyu;Han, Kyung-Soo;Kim, Jong-Young;Yang, Keun-Young
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.1
    • /
    • pp.59-73
    • /
    • 2001
  • This study was performed to investigate the effects of occlusal appliance on the mandibular position and the mandibular rotational torque movement during speech. For this study, 20 patients with temporomandibular disorders(TMDs) and 20 normal subjects without any signs and symptoms in the masticatory system were selected as the patient group and as the normal group, respectively. Biopak $system^{(R)}$(Bioresearch Inc., Milwaukee, USA) and a sentence of 'Sue is missing her house' were used for recording and for observing of speech pattern. There were five mandibular positions observed in this study, that is, mandibular rest position, 'ssi', 'her', 'ha', and 's' speech position. In each position, slant and A-P distance in sagittal plane, vertical distance and lateral distance in frontal plane were measured. Amount of the mandibular rotational torque movement were measured at 'her', 'ha' speech position and for all through speech movement. Centric relation splint(CRS) was placed in both groups, but anterior or posterior bite plane were placed in normal subjects only. Data collected were processed and analysed by SPSS windows program. The results of this study were as follows : 1. Mandibular positions in both groups were not different before adaptation, with CRS, and after removal, but total amount of the mandibular rotational torque movement was greater in patients. 2. Mandible was slightly placed anteriorly with CRS at 'her' and 'ha' speech position in patients, but was placed anteriorly at all the five positions in normal subjects. 3. Difference with type of occlusal appliance in normal subjects were noted only for vertical distance at 'ssi' and 'ha' speech position, and the distance with CRS were more than that with posterior bite plane. 4. Mandibular rotational torque movement at 'her' and 'ha' speech position was greater in patients, but the difference was disappeared after appliance removal. And the torque movement was greater at 'ha' speech position than that at 'her' speech position in frontal plane. It could be concluded that the adaptation of occlusal appliance showed a tendency to locate the mandible anteriorly during speech in both groups, but did not affect total mandibular rotational torque movement which was greater in patients.

  • PDF

Tool Path Analysis and Motion Control of 3D Engraving Machine

  • Smerpitak, Krit;Pongswatd, Sawai;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1245-1248
    • /
    • 2004
  • This paper presents a new technique to analyze data on the coordinate x, y, z and apply these data to design the motion control to improve the efficiency of the engraving machine so that it can engrave accordingly in 3 dimensions. First, the tool path on the x-y plane is analyzed to be synchronized with the z-axis. The digital data is then sent to the motion control to guide the movement of the engrave point on the x-y plane. Tool path moves along the x-axis with zero degree and different values of the y-axis according to the coordinate of the digital data and the analysis along z-axis to determine the depth for engraving. The depth can be specified from the gray level with the 256 levels of resolution. The data obtained includes the distances on x-axis, y-axis, and z-axis, the acceleration of the engrave point's movement, and the speed of the engrave point's movement. These data is then transfered to the motion control to guide the movement of the engrave point along the z-axis associated with the x-y plane. The results indicate that engraving using this technique is fast and continuous. The specimen obtained looks perfect in 3D view.

  • PDF

Rainstorm Tracking Using Statistical Analysis Method (통계적 기법을 이용한 국지성집중호우의 이동경로 분석)

  • Kim Sooyoung;Nam Woo-Sung;Heo Jun-Haeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.194-198
    • /
    • 2005
  • Although the rainstorm causes local damage on large scale, it is difficult to predict the movement of the rainstorm exactly. In order to reduce the rainstorm damage of the rainstorm, it is necessary to analyze the path of the rainstorm using various statistical methods. In addition, efficient time interval of rainfall observation for the analysis of the rainstorm movement can be derived by applying various statistical methods to rainfall data. In this study, the rainstorm tracking using statistical method is performed for various types of rainfall data. For the tracking of the rainstorm, the methods of temporal distribution, inclined Plane equations, and cross correlation were applied for various types of data including electromagnetic rainfall gauge data and AWS data. The speed and direction of each method were compared with those of real rainfall movement. In addition, the effective time interval of rainfall observation for the analysis of the rainstorm movement was also investigated for the selected time intervals 10, 20, 30, 40, 50, and 60 minutes. As a result, the absolute relative errors of the method of inclined plane equations are smaller than those of other methods in case of electromagnetic rainfall gauges data. The absolute relative errors of the method of cross correlation are smaller than those of other methods in case of AWS data. The absolute relative errors of 30 minutes or less than 30 minutes are smaller than those of other time intervals.

  • PDF

A Comparison of EMG Activity for the Middle and Lower Trapezius Muscle in the Frontal and Scapular Plane According to Shoulder Abduction Angles (어깨관절의 이마면과 어깨면에서 벌림각도에 따른 중간 등세모근과 아래 등세모근의 근 활성도 비교)

  • Kim, Byung-Kon;Lee, Myoung-Hee
    • PNF and Movement
    • /
    • v.14 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • Purpose: The purpose of this study was to compare muscle activities in the frontal plane and scapular plane of the middle fiber and lower fiber of the trapezius muscle at different shoulder abduction angles. Methods: Twenty male and female students in their 20s participated in this study. Each subject maintained shoulder abduction at $75^{\circ}$, $90^{\circ}$, $125^{\circ}$, and $160^{\circ}$ in a standing position and repeated motions three times each in the frontal plane and the scapular plane. While maintaining the motions for 10 seconds in each posture, surface electromyography (EMG) was used to measure muscle activity of the middle fiber and lower fiber of the trapezius muscle. The collected EMG data were normalized using maximal voluntary isometric contraction (MVIC). Differences in muscle activity of the middle fiber and lower fiber of the trapezius muscles according to the angles at each plane were statistically processed using repeated measured analysis of variance, and an independent t-test was used to examine the differences between the two planes at each angle. Results: Muscle activity of the middle and lower trapezius during shoulder abduction in the frontal plane and scapular plane significantly increased as the angles increased (p<.05). However, muscle activity of the middle trapezius was significantly lower in the scapular plane than in the frontal plane for all shoulder abduction angles (p<.05). Conclusion: The results of this study suggest that during shoulder abduction, angles should be different according to the goals, and for training during an acute phase or early phase for functional recovery, it is more efficient to perform the training in the scapular plane than in the frontal plane.

Study on Kinematic Calibration of a Parallel-typed Machining Center Tool (병렬기구형 공작기졔의 기구학적 보정에 관한 연구)

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2237-2244
    • /
    • 2002
  • This research develops a low-cost and high accuracy kinematic calibration method based on the following principles: 1) the platform locations are accurately measured by a constrained movement to inspect a calibration target; 2) the constrained movement is chosen to guarantee the parameter observability; 3) the mechanical fixture to constrain the movement and the sensor to check the constrained movement are implemented by low-cost and high-accuracy devices; 4) the calibration is easily done at an industrial environment. The kinematic parameters calibrated with respect to a single plane aren't influenced due to the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that all kinematic parameters are estimated by minimizing the cost function.

Effect of Movement Plane and Shoulder Flexion Angle on Scapular Upward Rotator During Scapular Protraction Exercise (운동면과 어깨 관절 굽힘 각도가 어깨뼈 내밈 운동 시 어깨뼈 위쪽 돌림근에 미치는 영향)

  • Choung, Sung-Dae;Weon, Jong-Hyuck;Jung, Do-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • PURPOSE: This study was to determine the effect of the plane of movement (sagittal plane vs. scapular plane) and shoulder flexion angle ($90^{\circ}$ vs. $130^{circ}$) during scapular protraction exercises in healthy subjects by investigating the elecromyographic (EMG) activities of the serratus anterior (SA), upper trapezius (UT), and pectoralis major (PM). METHODS: Twenty-one healthy subjects participated in this study. Subjects performed maximal scapular protraction at the $90^{\circ}$ or $130^{\circ}$ shoulder flexion angles in the sagittal or scapular planes. Surface EMG was recorded from the SA and UT, and PM muscles. Dependent variables were examined by 2 (plane) ${\times}$ 2 (angle) repeated measures of analysis of variance (ANOVA). RESULTS: Significantly increased EMG activities in the SA and UT were found during scapular protraction exercise at the $130^{\circ}$ shoulder flexion angle in the sagittal and scapular plane. Also, EMG activity of the PM significantly decreased at the $130^{\circ}$ shoulder flexion angle in the sagittal plane and the $90^{\circ}$ and $130^{\circ}$ shoulder flexion in the scapular plane. CONCLUSION: we recommend scapular protraction exercise at the $90^{\circ}$ shoulder flexion in the sagittal plane to selectively strengthen the SA muscle with limitation of upper trapezius activity and at the $130^{\circ}$ shoulder flexion in the scapular plane to selectively strengthen the SA muscle with limitation of pectoralis major activity.

Detection and Quantification of Screw-Home Movement Using Nine-Axis Inertial Sensors

  • Jeon, Jeong Woo;Lee, Dong Yeop;Yu, Jae Ho;Kim, Jin Seop;Hong, Jiheon
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.6
    • /
    • pp.333-338
    • /
    • 2019
  • Purpose: Although previous studies on the screw-home movement (SHM) for autopsy specimen and walking of living persons conducted, the possibility of acquiring SHM based on inertial measurement units received little attention. This study aimed to investigate the possibility of measuring SHM for the non-weighted bearing using a micro-electro-mechanical system-based wearable motion capture system (MEMSS). Methods: MEMSS and camera-based motion analysis systems were used to obtain kinematic data of the knee joint. The knee joint moved from the flexion position to a fully extended position and then back to the start point. The coefficient of multiple correlation and the difference in the range of motion were used to assess the waveform similarity in the movement measured by two measurement systems. Results: The waveform similarity in the sagittal plane was excellent and the in the transverse plane was good. Significant differences were found in the sagittal plane between the two systems (p<0.05). However, there was no significant difference in the transverse plane between the two systems (p>0.05). Conclusion: The SHM during the passive motion without muscle contraction in the non-weighted bearing appeared in the entire range. We thought that the MEMSS could be easily applied to the acquisition of biomechanical data on the knee related to physical therapy.

Constraint Operator for the Kinematic Calibration of a Parallel Mechanism

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo;Kwon, Sung-Ha
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.23-31
    • /
    • 2003
  • This paper introduces a constraint operator for the kinematic calibration of a parallel mechanism. By adopting the concept of a constraint operator, the movement between two poses is constrained. When the constrained movements are satisfied, the active joint displacements are taken and inputted into the kinematic model to compute the theoretical movements. A cost function is derived by the errors between the theoretical movement and the actual movement. The parameters that minimize the cost function are estimated and substituted into the kinematic model for a kinematic calibration. A single constraint plane is employed as a mechanical fixture to constrain the movement, and three digital indicators are used as the sensing devices to determine whether the constrained movement is satisfied. This calibration system represents an effective, low cost and feasible technique for a parallel mechanism. A calibration algorithm is developed with a constraint operator and implemented on a parallel manipulator constructed for a machining center tool.

A Study on Mandibular Rotational Torque Movement in Subjects with Temporomandibular Joint Sounds (악관절음 환자의 하악 비틀림회전운동에 관한 연구)

  • So, Jong-Seob;Lee, Kyoung-Ho;Chung, Sung-Chang
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.4
    • /
    • pp.455-466
    • /
    • 1999
  • The purpose of this study was to investigate the magnitude of mandibular rotational torque movements in subjects with TMJ sounds, and to analyse correlation between quantitative characteristics of TMJ sounds and mandibular rotational torque movement. Twenty dental college students with TMJ clicking and twenty students without any TMD signs and symptoms were examined by mean of SonoPak and Rotate program of BioPAK system(Bioresearch Inc. MilWaukee, wisconsin, USA) in this study. Mandibular rotational torque movements were recorded and analysed during maximum mouth opening, protrusion, and lateral excursion in frontal and horizontal planes. The obtained results were as follows: 1. On maximum mouth opening, mandibular rotational angle and distance of clicking group were significantly greater than those of control group in frontal plane. (P<0.05). 2. During maximum mouth opening closing, maximum mandibular rotational angle and distance of clicking group were significantly greater than those of control group in frontal plane. (P<0.01). 3. On protrusion, mandibular rotational angle and distance of clickin group were significantly greater than those of control group in horizontal plane. (P<0.05). 4. On lateral excursion, there was no significant difference in mandibular rotational angle and distance between clicking group and control group in frontal and horizontal planes. 5. There were significant correlations between peak amplitude of TMJ sounds and maximum mandibular rotational distance during maximum mouth opening (r=-.481) and mandibular rotational distance on maximum mouth opening (r=-.455) in horizontal plane. 6. There were significant correlations between Above 300/(0-300)Hz ratio of TMJ sounds and mandibular rotational angle (r=-.499) and distance (r=-.457) on maximum mouth opening in frontal plane.

  • PDF