• Title/Summary/Keyword: Movement noise

Search Result 304, Processing Time 0.024 seconds

User-Adaptive Movement Noise Detection Algorithm Using Wavelet Transform (Wavelet을 이용한 사용자 적응 동잡음 판단 알고리즘)

  • Ban, Dahee;Kwon, Sungoh
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1120-1129
    • /
    • 2015
  • In this paper, we propose an algorithm to detect movement noise in PPG(Photoplethysmography) measurements. Movement noise significantly deteriorate PPG signals in measurement, so that a movement noise detection algorithm is critical before using measured PPG signals for applications such as diagnosis. To detect movement noise, we apply wavelet transform to PPG signals instead of short-time Fourier transform and decide if the measured signlas include movement noise. To that end, we adaptively choose a wavelet, which is the most similar to the subject's PPG pattern. In the case when movement noise is intentionally added in the 20% and 30% of the total experiment time, our algorithm detects time-slots including movement and outperforms previous works.

Patterns of Mandibular Movement of Patients with TMJ Noise (악관절잡음 환자의 하악운동양상)

  • Sung Chang Chung;Young Ok Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.11 no.1
    • /
    • pp.19-27
    • /
    • 1986
  • Registration of the mandibular movement in patients with temporomandibular joint noise (clicking and/or crepitus) was performed using one of mandibular tracking devices(SAPHON VISI-TRAINER CII,Tokyo Shizai-sha Inc.,Japan). The obtained results were follows : 1. In many cases, the movement pattern of light emitting diode(LED) attached on the mandibular midline showed lateral deviation from a vertical reference line which was pronounced in association with TMJ noise during opening and closing. 2. In patients with unilateral TMJ noise the mandibular midline usually towards the side demonstrating TMJ noise during opening. 3. A distinct V-shaped discontinuity in the trace of velocity of mandibular movement was found at the point of the TMJ noise. 4. In patients with TMJ noise the velocity of mandibular movement at the point of the TMJ noise was decreased rapidly. 5. In several cases, TMJ noise could be eliminated by traning of Rocabado`s control of TMJ rotations.

  • PDF

A Noise Prediction Method on the Movement Measuring Points at Measurement for Aircraft Noise (항공기 소음 측정 시 이동측정지점에 대한 소음도 예측방법)

  • Woo, Jeong Ha;Lee, Byung Chan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.12
    • /
    • pp.901-906
    • /
    • 2015
  • It is difficult to measure aircraft noise at many points, because the noise measurement is need to long time, 24 hours and consecutive 7 days, which results in high costs. As an alternative, movement measuring points are set to measure aircraft noise for less than 24 hours, and so it is needed to overcome the limitation of shorter measuring time. Thus, this study measured military aircraft noise on movement measuring points and conducted a comparative analysis on the data according to each measuring time. The data of measuring noise for 24 hours and less than 24 hours were compared to suggest appropriate measuring time on the movement measuring points. As a result of comparing data of measuring noise, an error was within 3 dB in case of measuring time of 3 hours, and an error was within 1 dB in case of 6 hours of measurement.

The Design of Temporal Bone Type Implantable Microphone for Reduction of the Vibrational Noise due to Masticatory Movement (저작운동으로 인한 진동 잡음 신호의 경감을 위한 측두골 이식형 마이크로폰의 설계)

  • Woo, Seong-Tak;Jung, Eui-Sung;Lim, Hyung-Gyu;Lee, Yun-Jung;Seong, Ki-Woong;Lee, Jyung-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.144-150
    • /
    • 2012
  • A microphone for fully implantable hearing device was generally implanted under the skin of the temporal bone. So, the implanted microphone's characteristics can be affected by the accompanying noise due to masticatory movement. In this paper, the implantable microphone with 2-channels structure was designed for reduction of the generated noise signal by masticatory movement. And an experimental model for generation of the noise by masticatory movement was developed with considering the characteristics of human temporal bone and skin. Using the model, the speech signal by a speaker and the artificial noise by a vibrator were supplied simultaneously into the experimental model, the electrical signals were measured at the proposed microphone. The collected signals were processed using a general adaptive filter with least mean square(LMS) algorithm. To confirm performance of the proposed methods, the correlation coefficient and the signal to noise ratio(SNR) before and after the signal processing were calculated. Finally, the results were compared each other.

Visualization of pass-by noise by means of a line array of microphones affixed to the ground (지면에 고정된 선형 마이크로폰 어레이를 이용한 pass-by 소음의 가시화)

  • Park, Soon-Hong;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1479-1486
    • /
    • 2000
  • This paper introduces the improved moving frame acoustic holography (MFAH) method and its application. MFAH allows us to visualize the noise generated by moving noise sources by employing a vertical line array of microphones affixed to the ground. The sound field generated by moving sources is different from that of stationary ones due to the movement of the sources. Therefore the measured sound pressure by the microphone on the ground has to be processed so that it cooperates the effect of the movement. This paper discusses the effect of moving noise sources on the obtained hologram by MFAH. This assures the applicability of MFAH to the visualization of moving sources. This paper also reviews the improved MFAH that can visualize a coherent narrow band noise and a pass-by noise. The practical applicability of the improved MFAH was demonstrated by visualizing tire noise during a pass-by test.

  • PDF

Assessment of Sleep Disturbance on Night-time Instantaneous Railway Noise by using Actiwatch (Actiwatch 를 이용한 철도소음에 의한 수면방해의 정량적 평가)

  • Hong, Ji-Young;Kim, Jae-Hwan;Lim, Chang-Woo;Kim, Ku-Tae;Sung, Dong-Won;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.759-763
    • /
    • 2006
  • The World Health Organization(WHO) has recommended population of sleep disturbance as one of the environmental health indicators. But the percentage of respondents who felt highly sleep disturbed, that is, %HSD can???thave application to sleep disturbance from instantaneous noise. Therefore, this study has been carried out to present the technique for assessing sleep disturbance on instantaneous noise quantitatively. The study of sleep disturbance on night time instantaneous railway noise has been undertaken. Noise monitor has been in operation from 22 hours to 7 hours during 6 nights at 12 locations. To assess instantaneous noise induced sleep disturbance, it was decided to measure body movement by actiwatch. %motility was used as indicators of sleep disturbance. %motility is the expected value of probability of motility value during 7 epochs (105s) of any noise event. The measures of instantaneous motility have been related to measures of instantaneous railway noise events. The relationship shows that %motility is a good predictor for assessing sleep disturbance and Korean is more sensitive to noise than European although the railway noise have been considered in this study. This study can be extended to assessing long-term sleep disturbance and give a guideline far policy decision.

  • PDF

Development and Evaluation Archery Posture Analysis System using Inertial Sensor (관성센서를 이용한 양궁자세 분석 시스템 구축 및 평가)

  • Cho, WooHyeong;Quan, Cheng-Hao;Kwon, Jang-Woo;Lee, Sangmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1746-1754
    • /
    • 2016
  • In this paper, we provide a development and evaluation method for an archery posture analyzing system, using an inertial sensor. The system was developed using LabVIEW2014 by National Instruments and evaluated using the DTW algorithm. To convert the voltage value of the inertial sensor into a physical value, a coordinate transformation matrix bias was applied. To evaluate the similarity of movement in archery shooting, the DTW distance was calculated and similarity was confirmed based on simple mechanical movement, the same person's shooting movement, shooting movement with another person, and the noise signal. The average similarity comparison results were as follows: simple mechanical movement was 17.05%, the same person's shooting movement was 26.48%, shooting movement with another person was 62.8%, and the noise signal was 328.5%; a smaller value indicates a higher level of similarity. We confirmed the possibility of analyzing the archery posture using 3-axis acceleration of the inertial sensor. We inferred that the proposed method might be important means for assessing shooting skills, evaluation of archer's progress, and finding talented archers in advance.

Dynamic analysis of an elastic shaft with consideration about Journal bearing (압축기의 Bearing 윤활을 고려한 탄성체 Shaft의 동적 거동 해석)

  • Lee, Yun-gon;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.768-770
    • /
    • 2014
  • A shaft of a reciprocating compressor receives bending force by piston, which makes movement of the shaft. The movement of the shaft affects durability and becomes a source of noise. In this paper, a cylinder is modeled by considering motion of a suction and discharge valve. The journal bearing is modeled by Bernoulli's equation. The trajectory of shaft which is considered cylinder and journal bearing can be calculated by finite element method. It will help a design of shaft to increase durability and reduce noise.

  • PDF

A Real Time QRS Detection Algorithm Based-on microcomputer (마이크로 컴퓨터를 이용한 실시간 QRS검출 앨고리즘)

  • 김형훈;이경중;이성환;이명호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.4
    • /
    • pp.127-135
    • /
    • 1986
  • This paper represents a real time algorithm which improves the some drawbacks in the past methods for detection of the QRS conplexes of ECG signals. In the conventional method we can't detect QRS complex and QRS duration more correctly in case of (1) the contaminated ECG with 60Hz noise, muscle noise. (2) the movement of the baseline for a QRS complex. (3) being abnormal QRS complex with prolonging QRS. Therefore, we have proposed a new algorithm which can detect accurate QRS complex detection in case of the contaminated ECG with 60Hz noise, muscle noise, and movement of baseline for QRS complex. Moreover, in case of prolonging QRS we accomplished to detect not only QRS complex but also a single pulse that has a width proportional to QRS duration. This algorithm which is proposed in our paper in our paper in programmed with 6502 assembly language for real time ECG signal processing.

  • PDF

Noise Reduction of PPG Signal During Free Movements Using Adaptive SFLC(Scaled Fourier Linear Combiner) (적응 SFLC(Scaled Fourier Linear Combiner)를 이용한 활동 중의 PPG 신호의 잡음 감소)

  • Kim, Sung-Min;Cha, Eun-Jong;Kim, Deok-Won;Yoo, Jae-Ha;Kim, Dong-Yon;Kim, Soo-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.138-141
    • /
    • 2006
  • Blood flow is one of vital signals related to human physiological information. Photoplethysmograph (PPG) has been used to measure indirectly heart rate, blood oxygen saturation ($SpO_2$), and so on. Because PPG signal is weak and sensitive to motion artifacts, it is very important to continuously obtain stable PPG signal during free movement. In this study, we applied the scaled Fourier linear combiner (SFLC) using both the adaptive filter and FLC to remove effectively the motion artifacts as well as background noise in the real time without additional signal correlated with motion from a accelerometer. The proposed method would be useful to reduce the movement and background noise which are not synchronized with heart rate.