• Title/Summary/Keyword: Movement evaluation

Search Result 1,110, Processing Time 0.035 seconds

Evaluation of friction of esthetic brackets according to different bracket-wire angulations (심미 브라켓의 종류와 브라켓-호선 각도에 따른 마찰 저항에 대한 연구)

  • Je, Young-Ji;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.5
    • /
    • pp.341-350
    • /
    • 2007
  • The purpose of this study was to evaluate how the friction that occurs during the sliding movement of the archwire through esthetic brackets is differently affected by bracket materials, slot designs, and tip angulations of the archwire. Methods: Eight types of brackets with 0.018 inch slots (composite: Brillant (BR); composite with metal slot: Spirit MB (SP); ceramic: Inspire (IN), Signature (SI), Cristaline V (CR); ceramic with metal slot: Clarity (CL), Luxi II (LU); and metal bracket: Integra (IT)), and placed into groups of 20 brackets in each group, were tested in artificial saliva with 0.018 inch stainless steel wire. The wire tip angulations were given as 0, 4 and 8 degrees. Results: CR group significantly showed the lowest frictional force with all wire tip angulations of 0,4, and 8 degrees. IN significantly showed the highest frictional force (p < 0.001). BR (polyoxymethylene) had significantly less frictional force than SP (polycarbonate) (p < 0.001) and showed no significant difference between metal brackets. Friction was increased as the wire tip angulations were increased, but no notches were observed on any parts of the archwire. Conclusions: According to the results of this study, esthetic brackets are superior or similar to 55 brackets from a frictional point of view.

The effect of temporomandibular joint movement on tinnitus (턱의 운동이 이명에 미치는 영향)

  • Kim, Jeong-Mo;Kim, Tae Su;Nam, Eui-Cheol
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.333-338
    • /
    • 2013
  • Purpose: A growing number of studies have been providing evidence for neural connections between the auditory and somatosensory systems that might be a critical part of the mechanisms underlying certain forms of tinnitus. The aim of this study was to investigate the effect of temporomandibular joint (TMJ) movements on tinnitus. Methods: One hundred sixty-three tinnitus patients participated in this study. All patients underwent a thorough audiological examination including pure-tone audiometry, tinnitus handicap inventory, and evaluation of tinnitus loudness, frequency and severity on a visual analog scale. Somatic testing consisting of nine forceful jaw muscle contractions was performed to evaluate the effect of TMJ movements on modulation of tinnitus. Results: 66.9% of patients had unilateral tinnitus. Somatic testing modulated tinnitus loudness in 125 ears (57.6 %) of 217 ears tested. An increase in tinnitus loudness was observed more often than a decrease. Loudness was most commonly increased by opening and clenching jaw. Tinnitus could be induced by opening, clenching and deviating jaw to the left. Conclusion: Our study showed evidence that TMJ movements may aggravate and even evoke tinnitus and somatic testing can be used for evaluating if stimulation of the TMJ induces or aggravates tinnitus.

EFFECTS OF THE SITE AND THE EXTENT OF BLOWOUT FRACTURE ON ENOPHTHALMOS AND DIPLOPIA (Blowout 골절의 부위와 정도가 안구함몰 및 복시에 미치는 영향)

  • Hwang, Ung;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.292-300
    • /
    • 2004
  • Orbital blowout fractures are common consequence to blunt periorbital trauma. Pure orbital blowout fractures first occur at the weakest point of the orbital wall. Computed tomography(CT) is recognized to be the best imaging technique to evaluate orbital fractures. The extent and location of a blowout fractures in the CT scan were noted to have an effect on the clinical outcome. In the early posttraumatic period, the presence of significant enophthalmos is difficult to detect because of orbital edema. Early surgical intervention may improve the ultimate outcome because open reconstruction becomes more difficult if surgery is delayed. In this study, we evaluated isolated blowout fractures of the orbital floor by region-of-interest measurements from CT scans and their relationship to ophthalmologic findings. Six patients of the medial orbital wall fractures, eleven patients of the inferior orbital wall fractures, nineteen of the medial and the inferior orbital wall fractures confirmed by CT scan, were evaluated. The area of fracture and the volume of the displaced orbital tissue were determined from CT scan using linear measurements. Each of the calculated values for the area and the volume were compared with the degree of the enophthalmos, the diplopia, and the eyeball movement limitation to determine whether there was any significant relationship between them. The fracture area and the volume of the herniated orbital tissue were significantly positively correlated with the enophthalmos and the ocular motility limitation and not correlated with the diplopia. For the enophthalmos of 2mm or greater, the mean fracture area was 3.55{\pm}1.25cm^2$ and the volume of the herniated orbital tissue was $1.74{\pm}0.97cm^3$; for less than 2mm enophthalmos, $1.43{\pm}0.99cm^3$ and $0.52{\pm}0.49cm^3$, respectively. The enophthalmos of 2mm can be expected with $2.92cm^2$ of the fracture area and $1.40cm^3$ of the herniated orbital tissue. In conclusion, the enophthalmos of 2mm or more, which is a frequent indication for surgery. It can be expected when area of fracture is $2.92cm^2$ or more, or the volume of herniated orbital tissue is $1.40cm^3$ or more. And the CT scan using linear measurements has an application in the assessment of patients with blowout fractures and provides useful information in the posttraumatic evaluation of orbital fractures.

Correlations between Air Freight Logistic Service and Business Performance of Forwarder (항공화물 물류관리 서비스와 경영성과의 상관성: Forwarder의 수익률 효과분석)

  • Kim, Joong-Kwan
    • International Commerce and Information Review
    • /
    • v.16 no.1
    • /
    • pp.145-161
    • /
    • 2014
  • The study has try to find out the relationship between airfreight service quality and satisfaction in international forwarding practice which has focused to figure out the mediating role of performance that measured as subjective evaluation on profit. For the purpose of this paper, questionnaire survey has been performed on the relationship among the procedure of the air freight service quality was found to have not only direct influence but also indirect impact through performance on satisfaction. This research made some contribution both academicals and logistic practices. Academically, it is the first research to address the relationship between air freight service quality and profit performance in Korean academic field. Practically, this study provides justification for the investment to improve forwarding service quality. The results of this study bear some implications on international shipping and practice. The quality of the air cargo transportation management system for customer satisfaction and its impact on business performance in the process to make an empirical identifies. The role and influence of the working-level analysis to derive the performance as transportation management, as well as the effectiveness of customer satisfaction for quality and promote a point. Arrange this point take advantage of air cargo companies are composed of service quality management system for the dimension of course aims to foster a competitive advantage in terms of performance. This paper suggest that real-time movement of the consignment route provides information such as verification and business cooperation for the purpose of proper features a reflecting on the stability of cargo air freight management system, that improve the quality of services on this performance to increase the customer satisfaction strategy in connected getting and so on, is in the process of the formation of customer satisfaction.

  • PDF

A Study on Securing a Stable GM for Each Ship Type Considering the Ship's Operating Status (선박의 운항 상태를 고려한 선종별 안정적인 GM 운용에 관한 연구)

  • Kim, Hong-Beom;Kim, Jong-Kwan;Lee, Yun-Sok
    • Journal of Navigation and Port Research
    • /
    • v.44 no.4
    • /
    • pp.275-282
    • /
    • 2020
  • Recently, the occurrence of a ship capsizing was analyzed as the main cause of the lack of stability or loss because of the improper management of the center of gravity, the movement of cargo or heavy weight when excessive steering occurs or when navigating during bad weather. Thus, to prevent a ship from capsizing, it is necessary to secure stability to enable the ship's return to its upright position, even if a dangerous heel occurs. The GM is a crucial evaluation factor regarding stability, which the navigation officer uses to preserve stability. In this study, based on the stability data collected from the operating of ships for five years, The GM by ship's type according to the operating status was analyzed specifically such as a ship's length, breadth, and gross tonnage. The feature of the GM distribution according to a ship's length was confirmed, and after performing the correlation analysis between the breadth and the GM, the ratio of the GM to breadth was calculated, and the result was compared with the previous ratio. Additionally, a simple approximation formula and minimum GM for the estimation of the GM by ship type were proposed by the regression analysis of the GM using the gross tonnage (GT)/breadth (B) to reflect the trend of larger ships being built. The results of this study are expected to be used as data for the review of securing a stable GM on ships.

A Study on Backup Route Setup Scheme in Ad Hoc Networks (애드혹 네트워크에서의 보조 경로 설정 기법에 관한 연구)

  • Jung Se-Won;Lee Chae-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.8 s.350
    • /
    • pp.47-58
    • /
    • 2006
  • Due to the movement of nodes, ad-hoc networks suffer from the problems such as the decrease of data delivery ratio, the increase of end-to-end delay, and the increase of routing overhead. The backup routing schemes try to solve these problems by finding the backup routes during the route discovery phase and using them when a route fails. Generally the backup routing schemes outperform the single-path routing schemes in terms of data delivery ratio, end-to-end delay, and routing overhead when the nodes move rapidly. But when the nodes don't move rapidly, the backup routing schemes generate more routing traffics than the single-path routing schemes because they need to exchange packets to find the backup route. In addition, when the backup route fails earlier than the main route, it can not use the backup route because in many backup route algorithms, the backup route is found only at the initial route discovery phase. RBR(Reactive Backup Routing Algorithm) proposed in this paper is an algorithm that provides more stable data delivery than the previous backup routing schemes through the selective maintenance of backup route and the backup route rediscovery. To do that RBR prioritize the backup routes, and maintain and use them selectively Thus it can also decrease the routing overheads. Also, RBR can increase data delivery ratio and decrease delay because it reestablishes the backup route when the network topology changes. For the performance evaluation, OPNET simulator is used to compare RBR with the single-path routing scheme and some of the well known backup routing schemes.

Analysis on Reactions of Full-Scale Airframe Static Structural Test (항공기 전기체 정적구조시험의 반력 분석)

  • Shim, Jae-yeul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.3
    • /
    • pp.195-205
    • /
    • 2020
  • This study addresses analysis on reactions which are induced in restraint system for airframe full-scale static structural test. This system restraints 6 degrees of freedom of a test article. It is valuable to study evaluating test error through analysis on the reactions which include all errors in a test. It is required to calculate fistly right reactions for the evaluation. This study focuses on calculation of the right reactions. The reaction is represented by sum of nominal reaction(Rn) and testing error reactions(Rce, Rerr) and is analyzed by two steps (inital vs relative reaction) in this study. It would evaluate intrinsic error at 0%DLL and error induced from applying test load, separately. Based on analysis using test data of a full-scale static test(canard type aircraft), resultant force of Rces and Rce_rs are distributed within 82.8N while resultant force of Rerr_rs shows to increase upto max. 808N as load level increment. Such well distribution of the Rce within the small range is caused from TMF values characteristics which are well distributed within -30N~40N. Additionally, it is shown through qualitative analysis on three components(X0, Y0, Z0) of the relative reaction(Rerr_r) that the reactions must be calculated with considering deformation of test article to calculate correctly reactions. This study shows also that equations characterizing deformation of components of test article are required to calculate the correct reactions, the equations must include information which will be used to calculate movement of all loading points.

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET (13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가)

  • Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.20-23
    • /
    • 2016
  • Purpose Because of heart movement, PET image of heart is very blur. So, PET scan gated with ECG is necessary to improve a spatial resolution of heart PET image. In this study, we will evaluate a image quality of both gated $^{13}N-ammonia$ PET scan and non-gated one. Materials and Methods Before start a heart PET, we attached a ECG electrode on patients (n = 5, $aged=54{\pm}17$). And we started a list mode PET scan that used by a mCT40 PET/CT (siemens, germany) during 10 minute, injected $^{13}N-ammonia$ ($378{\pm}50MBq$) to a patients at same time. By using this list mode data, we reconstructed both gated PET image and non-gated PET image. Then we analysed a profiles of those images, performed a blind test, and subtracted a gated image on non-gated image. Results FWHM of a gated image is improved about 23% and there is a differency count distribution at a subtracted image from non-gated image to a gated image. But in case of blind test, everybody select the gated image as a better quality among each images. Conclusion As a result, we can find that image quality will improve by using gated PET scan. In additional, we can calculate a EF valve, apply QGS, QPS of PET. Therefore, the gated PET scan help improving an accuracy, applying a more information for a diagnosis.

  • PDF

The Study on the Skin Penetration of Cosmetic Ingredient with in vivo Raman Spectroscopy and in vitro Franz Cell (라만 분광 피부 측정기를 이용한 기능성 화장품 성분의 in vivo 피부 투과 측정 및 in vitro 비교 평가 연구)

  • Jeon, Serim;Han, Min-Hee;Chung, Dae-Kyun;Hwang, Jae-Sung
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • At present, there are few research papers on skin penetration of cosmeceutical ingredients. What is worse is that in vivo studies are hard to find. In this study, we measured skin epidermal penetration of cosmeceutical ingredients using in vivo Raman spectroscopy and compared with the results obtained from experiments using in vitro franz cell. Results showed that ascorbyl-2-glucoside, retinol, retinyl palmitate, and kojic acid were good for penetration ratio in measurement in vitro and retinol, vitamin C, and arbutin were good in measurement in vivo. Among them, retinol was best in skin penetration in vivo experiment using Raman spectroscopy and ascorbyl-2-glucoside was best in skin penetration in vitro experiment using Franz cell system. It is estimated that the differences were originated from the experimental procedures of two different methods; in vivo Raman experiment can be sensitive to the effect of epidermis and dermis as characteristics of matter by estimating the stratum corneum and in vitro measurement is evaluation of material to penetrate skin of hairless mouse. However, most penetration barrier is the stratum corneum, thus it is important to examine movement of material in the stratum corneum. We expect that these results provided useful information for many cosmetic related research.