• Title/Summary/Keyword: Movement evaluation

Search Result 1,110, Processing Time 0.028 seconds

QoS Guaranteed Handover Scheme for Global Roaming in Heterogeneous Proxy Mobile IPv6 Networks (이기종 프록시 이동(모바일) IPv6 네트워크에서 QoS가 보장된 글로벌 로밍 핸:드오버 방식)

  • Go, Kwang-Sub;Kim, Soo-Hyun;Kim, Mi-Sun;Mun, Young-Song
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Mobility and quality of service (QoS) are becoming the more important issues in wireless communications. The traditional Internet service is expanding into new access media and applications. Since wireless communication services are accompanied by frequent handovers at remote sites, scalable and fast handover has become a prerequisite for ubiquitous communication. In this paper, the differentiated service (Diffserv) model is deployed in heterogeneous proxy mobile IPv6 (PMIPv6) networks to satisfy the QoS guaranteed service and fast handover requirements. The operational procedures for QoS guaranteed global roaming are presented. In addition, QoS management and handover cost evaluation schemes based on a mobile host's movement scope are proposed. This paper analyzes the reduction in handover delay in a network-based localized mobility management framework. We propose and analyze a PMIPv6 optimized with a global mobile access gateway (G-MAG), which is a network-based entity, to further improve the handover performance in terms of handover delay while maintaining minimal signaling overhead in the air interface among converged heterogeneous wireless networks. The handover signaling procedures with host-based MIPv6 are compared with network-based proxy MIPv6 (PMIPv6) and fast PMIPv6 assisted by G-MAG to show how much handover delay reduction can be achieved. Analytical results show that the handover delay is significantly reduced.

Preliminary Study to Develop an Objective Method for Evaluating Facial Palsy Sequelae Using Facial Scanning System (안면계측검사를 통한 안면마비후유증 객관적 평가도구 개발을 위한 기초 연구)

  • Ryu, Soo Hyeong;Lee, Su Yeon;Kim, Hong Guk;Ryoo, Dek Woo;Kim, Sung Jin;Jeong, Seong Mok;Baek, Seung Won;Goo, Bon Hyuk;Kim, Min Jeong;Park, Yeon Cheol;Seo, Byung Kwan;Nam, Sang Soo;Baek, Yong Hyeon
    • Journal of Acupuncture Research
    • /
    • v.33 no.3
    • /
    • pp.89-99
    • /
    • 2016
  • Objectives : This study was performed to develop objective methods for evaluating facial palsy sequelae using a 3D Facial Scanning System. Methods : Fifty-eight patients with facial palsy sequelae were selected. Their medical records were reviewed to collect demographic data, facial palsy sequelae evaluation, Facial Disability Index questionnaire, and test results (3D Facial Scanning System). Five different facial expressions (at rest, eye closure, eyebrow elevation, smiling, and whistling) were photographed. Sunnybrook Scale was associated with distances between predetermined facial points. Results : The average Sunnybrook composite score was $58.88{\pm}17.31$. Secondary movements (mouth to eye synkinesis, contracture of eye, and contracture of mouth) showed significant difference according to the Sunnybrook Scale. In voluntary movements, eyebrow height at eyebrow elevation, length between mouth angle and central line while whistling, and eyelid width at maximum eye opening showed significant difference. Facial palsy Sequelae Index (FSI) was correlated with Sunnybrook sub-scales (resting symmetry, voluntary movement, and synkinesis). Conclusion : These results demonstrate that a 3D Facial Scanning System is useful for evaluating facial palsy sequelae. This method may facilitate objective evaluation for facial palsy sequelae and it could be applied in clinical trials.

Performance Evaluation of PCR Kits for Detecting Genetically Modified Crop Ingredients (유전자 변형 작물 성분 검출용 PCR Kit의 성능 평가 연구)

  • 윤시온;정순천;윤원기;박상규;문제선;이정현;김환묵
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.101-108
    • /
    • 2004
  • The different social reflections about the benefits and the potential risks of genetically modified (GM) crops have evolved with .different reactions in different countries. Many countries including Korea are working toward setting down new guidelines. Korea requires companies to label all food that contains more than 3% GM ingredients. One of the rapid and convenient detection methods of GM ingredients is amplification of the introduced DNAs by polymerase chain reaction (PCR). Many PCR kits for this purpose are commercially available. The objective of this study was to evaluate performance of commercialized GM crop detection kits. The results showed that 6 out of 15 kits tested did not meet the requirements even purposed by the manufacturers themselves in terms of stability, reproducibility, and detection limits, suggesting a potential quality control problem in their design stage or production line. The evaluation also suggests that, although the duplex and triplex detection kits allowed unambiguous detection in a single PCR reaction, the monoplex detection kits were the most sensitive to the detection of GM ingredients. The detection limits also differ between soybean and corn. Results from this study will be useful in the development of sound qualitative tracking systems of GM ingredients for monitoring throughout the cultivation of GM crops, their trans-boundary movement, and food production using GM grains as well as for complying with government guidelines associated with GM crops.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Algorithm of Generating Adaptive Background Modeling for crackdown on Illegal Parking (불법 주정차 무인 자동 단속을 위한 환경 변화에 강건한 적응적 배경영상 모델링 알고리즘)

  • Joo, Sung-Il;Jun, Young-Min;Choi, Hyung-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.6
    • /
    • pp.117-125
    • /
    • 2008
  • The Object tracking by real-time image analysis is one of the major concerns in computer vision and its application fields. The Object detection process of real-time images must be preceded before the object tracking process. To achieve the stable object detection performance in the exterior environment, adaptive background model generation methods are needed. The adaptive background model can accept the nature's phenomena changes and adapt the system to the changes such as light or shadow movements that are caused by changes of meridian altitudes of the sun. In this paper, we propose a robust background model generation method effective in an illegal parking auto-detection application area. We also provide a evaluation method that judges whether a moving vehicle stops or not. As the first step, an initial background model is generated. Then the differences between the initial model and the input image frame is used to trace the movement of object. The moving vehicle can be easily recognized from the object tracking process. After that, the model is updated by the background information except the moving object. These steps are repeated. The experiment results show that our background model is effective and adaptable in the variable exterior environment. The results also show our model can detect objects moving slowly. This paper includes the performance evaluation results of the proposed method on the real roads.

  • PDF

Occlusal Analysis in the Policemen with Temporomandibular Disorders Using T-scan II System (경찰 종사자의 측두하악장애환자에서 T-scan II System을 이용한 교합분석)

  • Lim, Hyun-Dae;Jung, Seung-Ah;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.365-373
    • /
    • 2006
  • This study suggested correction of excessive mouth opening or maximum occlusal contact to analyse occlusal contact time, occlusal contact number and force through evaluation of occlusal pattern in policemen with temporomandibular disorders. The community of policemen influence on temporomandibular disorder's development and progress due to other condition of mouth opening and maximal occlusal contact. Repeated training or changes of usual life style may cause imbalance of stomatognathic system including the masticatory muscle, then develop or aggravate pain of temporomandibular joints and associated structures. This study uses T-scan II system(Tekscan Co., USA) for evaluation on occlusal pattern may influence temporomandibular disorders, and then the subjects take a sensor at 20 mm opening for maximal occlusal contact force. The policemen with temporomandibualr disorders get more long time on maximum contact timing, more short on end contact timing, and more force on end contact force than general society's. So they get closure of mouth with more short time and more force, then transfer remaining load to temporomandibular joint. There are no statistically significances between affected side and occlusal pattern of occlusal contact time and force. There are Left -right dental arch imbalances seems on Rt. dental arch if affected side is right and Lt. dental arch if affected side is left. In above results, It's worth due consideration that policemen with temporomandibular disorders get more smooth mandibualr movement and less force on maximal occlusal contact position.

Behavior Evaluation of Thin Bonded Continuously Reinforced Concrete Overlay on Aged Jointed Concrete Pavement(2) (노후 줄눈 콘크리트 포장 보수를 위한 얇은 연속 철근 콘크리트 덧씌우기 포장의 거동 평가(2))

  • Ryu, Sung-Woo;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.101-110
    • /
    • 2010
  • In this paper, it has been studied about the CRCO to maintain or rehabilitate the aged JCP. The CRCO and JCO was constructed at useless section of Seo-Hae-Ahn express highway in South Korea. The performance evaluation was conducted. Especially, it was focused on the roll of longitudinal reinforced steels inserted into the CRCO. On crack survey results from field construction section, the reflection cracks at joint of the existing pavement occurred in CRCO. However, due to the constraints of longitudinal reinforced steels, crack width was small. Total crack length and quantity in the CRCO more than that in the JCO. And crack spacing in the CRCO was narrower than it in the CRCP. Through the bonding strength test results, if the cold milling and cleaning as well as surface treatment is applied, there will be no debonding problem at interlayer in the early age. From analysis of the horizontal behavior at the joint, the longitudinal reinforced steels constrained crack width which became wider than initial state over time. Also, that steel in the CRCO reduced the horizontal movement due to temperature variation(4 times than that in the JCO). But, if interface is debonded, the roll decreased. Vertical VWG data showed that CRCO did not occur debonding problem at steel location, but there was some problem in JCO. It was confirmed by field coring. The tensile strain appeared in the CRCO, But the compressive strain occurred in the JCO in early age. Through the FWD test result, deflection in the CRCO was less than that in the JCO. And K value in the CRCO was greater than it in the JCO.

Tracheal Resection and End to End Anastomosis for Tracheal Stenosis in Children (기관절제 및 단단문합술에 의한 소아 기관협착증의 치료)

  • Choi, Jong-Ouck;Chung, Keun;Kim, Young-Hwoan;Kim, Hye-Jung;Park, Chan;Choi, Geon
    • Korean Journal of Bronchoesophagology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 1997
  • Background and Objectives : In children with tracheal stenosis, operative management remains a challenging problem due to difficulties of operative techniques and postoperative care. The purpose of this study was to determine the effectiveness of tracheal resection with end to end anastomosis as operative management for tracheal stenosis in children. Materials and Methods : 6 children with severe tracheal stenosis underwent tracheal resection with end to end anastomosis. Causes of stenosis were trauma in 1 case and prolonged intubation or tracheotomy in 5 cases. The diagnoses were made by radiologic evaluation (plain X-ray, CT, 3-Dimensional CT) and confirmed by direct laryngoscopy and ventilating bronchoscopy under general anesthesia. Thyroplasty and unilateral arytenoidectomy were performed in 1 case. Suprahyoid release was done in 1 case with severe adhesion. Decanulation was achieved following postoperative endoscopic examination and pulmonary function test. Postoperative physical and radiologic examinations were given at regular intervals. Results : Stenosis were improved from grade III grade I in 4 cases and from grade II to grade I in 2 cases. Decanulation was achieved on average postoperative 6 months in 5 cases, and 10 years in 1 case due to exertional dyspnea. There were 1 each case of immediate postoperative subcutaneous emphysema, pneumothorax and wound infection. Postoperative granulomas at anastomosis site were treated with laser vaporization under suspension laryngoscope and bronchoscope in 3 cases. There was 1 each case of delayed postoperative vocal cord palsy, aspiration pneumonia and loss of cough reflex. Conclusion In tracheal stenosis of children, tracheal resection with end to end anastomosis has good result with preservation of normal airway. Preoperative evaluation of local factors such as swallowing, vocal cord movement and cough reflex and general condition was important for successful treatment. As the cases in adults, authors considered this operation to be a curable operative management for tracheal stenosis.

  • PDF

A Study on Evaluation of Slope Stability and Range of Rockfall Hazard of Daljeon-ri Columnar Joint in Pohang, Korea (천연기념물 제415호 포항 달전리 주상절리의 사면안정성 평가 및 낙석 위험 범위 설정)

  • Kim, Jae Hwan;Kang, Mu Hwan;Kong, Dal-Yong;Jwa, Yong-Joo
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.505-515
    • /
    • 2021
  • In this study, we evaluated the slope stability of the Pohang Daljeon-ri columnar joint (Natural Monuments # 415) and calculated the maximum energy, jumping height and moving distance of rockfalls using a simulation. Based on the results, we established the range of rockfall risk. The slopes of the Pohang Daljeon-ri columnar joint have dip directions of 93.79°, 131.99°, 165.54° and 259.84° from left (SW) to right (NE). Furthermore, they have a fan-like shape. The Pohang Daljeon-ri columnar joints are divided into four sections depending on the dip direction. The measurement results of the discontinuous face show that zone 1 is 125, zone 2 is 261, zone 3 is 262, zone 4 is 43. The results of slope stability analyses for each section using a stereographic projection method correspond to the range of planar and toppling failure. Although it is difficult to diagnose the type of failure, risk evaluation of currently falling rocks requires further focus. The maximum movement distance of a rockfall in the simulation was approximately 66 m and the rockfall risk range was the entire area under slope. In addition, it is difficult to forecast where a rock will fall as it rolls in various directions due to topographic factors. Thus, the installation of measures to prevent falling is suggested to secure the stability based on the results of the rockfall simulations and its probabilistic analysis.

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su;Choi, Chansoo;Kim, Chan Hyeong;Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Kim, Seonghoon;Choi, Sang Hyoun;Lee, Soon Sung;Kim, Jina;Hwang, JinHo;Kang, Youngnam
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.103-109
    • /
    • 2019
  • Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.