• Title/Summary/Keyword: Movement evaluation

Search Result 1,110, Processing Time 0.025 seconds

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Using the Arthroscopic Remplissage of Anterior Shoulder Instability with Hill-Sachs Lesion (전방 견관절 불안정성에서 Hill-sachs 병변의 관절경적 Remplissage)

  • Ko, Sang-Hun;Jung, Kwang-Hwan;Shin, Seung-Myeong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: We evaluated the minimal 1 year follow-up results (shoulder stability and the clinical and functional results) for the Remplissage technique to fill a Hill-Sachs lesion. Materials and Methods: The subjects were 12 patients who could be followed up for more than 12 months after the "Remplissage" procedures in our hospital from December 2008 to November 2009. Their mean age was 27.9 years old and the mean follow-up was 19 months. The evaluations included the ROM, the ASES score, the KSSI score, the ROWE score and postoperative MRI. Results: On the postoperative functional evaluation after an average of 16 months, the ASES score improved from 50.8 preoperatively to 78.3 postoperatively, the KSSI score improved form 44.5 preoperatively to 81.0 postoperatively and the ROWE score improved from 40.2 preoperatively to 84.3 postoperatively. After an average 14 months for all the cases, the range of movement was nearly in the normal range, which is 178.6${\pm}$18.6 (165~180) degrees for forward flexion and 49.3${\pm}$10 (43~60) degrees for external rotation. Conclusion: For recurrent shoulder instability with a large Hill-Sachs lesion, the Remplissage technique has a good outcome after more than 1 year follow-up in terms of the shoulder stability and the clinical and functional results.

Evaluation of Accuracy About 2D vs 3D Real-Time Position Management System Based on Couch Rotation when non-Coplanar Respiratory Gated Radiation Therapy (비동일평면 호흡동조방사선치료 시 테이블 회전에 따른 2D vs 3D Real-Time Position Management 시스템의 정확성 평가)

  • Kwon, Kyung-Tae;Kim, Jung-Soo;Sim, Hyun-Sun;Min, Jung-Whan;Son, Soon-Yong;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.601-606
    • /
    • 2016
  • Because of non-coplanar therapy with couch rotation in respiratory gated radiation therapy, the recognition of marker movement due to the change in the distance between the infrared camera and the marker due to the rotation of the couch is called RPM (Real-time The purpose of this paper is to evaluate the accuracy of motion reflections (baseline changes) of 2D gating configuration (two dot marker block) and 3D gating configuration (six dot marker block). The motion was measured by varying the couch angle in the clockwise and counterclockwise directions by $10^{\circ}$ in the 2D gating configuration. In the 3D gating configuration, the couch angle was changed by $10^{\circ}$ in the clockwise direction and compared with the baseline at the reference $0^{\circ}$. The reference amplitude was 1.173 to 1.165, the couch angle at $20^{\circ}$ was 1.132, and the couch angle at $1.0^{\circ}$ was 1.083. At $350^{\circ}$ counterclockwise, the reference amplitude was 1.168 to 1.157, the couch angle at $340^{\circ}$ was 1.124, and the couch angle at $330^{\circ}$ was 1.079. In this study, the phantom is used to quantitatively evaluate the value of the amplitude according to couch change.

Cryoanalgesia for the Post-thoracotomy Pain (늑간 신경 냉동요법에 의한 개흉술후 흉부 동통 관리)

  • Kim, Uk-Jin;Choe, Yeong-Ho;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 1991
  • Post-thoracotomy pain is so severe that lead to postoperative complications, such as sputum retention, segmental or lobar atelectasis, pneumonia, hypoxia, respiratory failure due to the patient`s inability to cough, deep breathing and movement. Many authors have been trying to reduce the post-thoracotomy pain, but there is no method of complete satisfaction. In 1974, Nelson and associates introduced the intercostal nerve block using the cryoprobe. The application of cold directly to the nerves causes localized destruction of the axons while preserving the endoneurium and connective tissue, thereby introducing a temporary pain block and able to complete regeneration of intercostal nerves. One hundred and two patients, who undergoing axillary or posterolateral thoracotomy at the Department of Thoracic and Cardiovascular Surgery in Korea University Medical Center between April 1990 and August 1990, were evaluated the effects of cryoanalgesia for the post-thoracotomy pain reduction. The patients were divided into two groups: Group A, control, the patients without the cryoanalgesia[No.=50], Group B, trial, the patients with cryoanalgesia[No.=52]. Before the thorax closed, in the group A, local anesthetics, 2% lidocaine 3cc, were injected to the intercostal nerves[one level with the thoracotomy, one cranial and caudal intercostal level and level of drainage tube insertion]. In the group B, cryoprobe was directly applied for 1 minute at the same level. Postoperative analgesic effects were evaluated by the scoring system which made arbitrary by author: The pain score 0 to 4, The limitation of motion score 0 to 3, The analgesics consumption score 0 to 3, The total score, the sum of above score, 0 to 10. For the evaluation of immediate analgesic effects, the score were evaluated at the operative day, the first postoperative day, the second postoperative day, and the seventh postoperative day. The effects of incision type, and rib cut to the post-thoracotomy pain were also evaluated. The results were as follows; 1. The intercostal block with cryoanalgesia reduced the immediate postoperative pain significantly compare with control group. 2. The intercostal block with cryoanalgesia improved the motion of the operation side significantly compare with control group. 3. The intercostal block with cryoanalgesia reduced the analgesics requirements at the immediate postoperative periods significantly. 4. The intercostal block with cryoanalgesia lowered the total score significantly compare with control group. 5. The intercostal block with cryoanalgesia were more effective to the mid-axillary incision than to the posterolateral incision 6. The intercostal block with cryoanalgesia were more effective to the patients without rib cut than to the patients with rib cut. 7. No specific complication need to be treated were not occurred during follow-up.

  • PDF

Time of Initial Detection of the Gestational Structures by Ultrasonography Examination in Small Pet Dogs (소형 애완견에서 초음파 검사에 의한 임신 구조물의 최초 관찰 시기)

  • Park, Sang-Guk;Kim, Bang-Sil;Yun, Chang-Jin;Yeo, Woon-Chang;Park, Chul-Ho;Kim, Jae-Pung;Lee, Suk-Kyung;Moon, Jin-San;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-ho
    • Journal of Embryo Transfer
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • Serial ultrasonographic examinations were daily performed from 15 days after ovulation until parturition to determine the time of first detection and ultrasonographic appearance of the fetal and extra-fetal structures in pregnant 10 Maltese, 10 Yorkshire Terrier, 15 Shih-tzu, and 10 Miniature Schnauzer bitches, respectively. Gestational age was timed from the day of ovulation (day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0ng/ml. The gestational length was $63.4{\sim}63.6$ (range: $61{\sim}65$) days and the geatational length was no statistically significant difference among bitches (p>0.05). The initial detection of the extra-fetal structures were; gestational sac at days $18.9{\sim}19.5\;(17{\sim}22)$, zonary placenta at days $24.6{\sim}25.5\;(23{\sim}28)$, yolk sac membrane at days $24.6{\sim}25.5\;(23{\sim}27)$, yolk sac tubular shape at days $26.1{\sim}26.3\;(24{\sim}28)$, and amniotic membrane at days $26.1{\sim}28.2\;(24{\sim}31)$, respectively. The time of the first detection of the extra-fetal structures were no statistically significant difference among bitches (p>0.05). The initial detection of the fetal structures were; embryo initial detection at days $22.5{\sim}22.9\;(21{\sim}24)$, heartbeat at days $23.2{\sim}23.8\;(21{\sim}25)$, embryo bipolar shape $27.6{\sim}28.9\;(26{\sim}30)$, fetal movement at days $31.9{\sim}32.8\;(27{\sim}34)$, limb buds at days $29.1{\sim}30.7\;(27{\sim}33)$, stomach at days $31.1{\sim}33.1\;(29{\sim}34)$, urinary bladder at days $32.4{\sim}33.2\;(29{\sim}35)$, skeleton at days $34.7{\sim}35.9\;(34{\sim}39)$, and kidney at days $42.1{\sim}44.7\;(41{\sim}48)$, respectively. The the time of the first detection of the fetal structures were no statistically significant difference among bitches (p>0.05). These results indicate the evaluation of the time of first detection and ultrasonographic characteristics of the gestational structures might be useful for pregnancy diagnosis, estimating fetal age, embryonic resorption, fetal monster, abnormal fetal growth and fetal viability, respectively.

Deformation Monitoring of a Structure Using Kinematic GPS Surveying Technology (Kinematic GPS 측량기법에 의한 구조물의 변형 모니터링)

  • 이진덕
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.27-40
    • /
    • 1998
  • This paper addresses the suitability of GPS positioning technology to monitoring deformation and movement of structures. The first part of the study is an empirical quantitative study of the repeatability of GPS observations and the second part is a performance evaluation of kinematic GPS, which requires only a few minutes per a point, for monitoring deformation of an engineering structure. On the test network for monitoring of a earth am, four observations have been conducted repeatedly on different seasons and water levels. The reference network was observed in static mode, and monitoring points were observed respectively in rapid-static mode as well as in kinematic mode in each epoch and then the results were compared with those obtained by conventional surveying techniques. The repeatability of baseline vectors to better than average 7 mm in three dimensions was achieved in base line observations between reference points and also the unclosure of reference networks showed the range of 4 ppm to 27 ppm. Compared with conventional surveying techniques, the kinematic approach showed the differences of 3∼4 m in slope distances which were observed from reference points to monitoring points, and showed the differences of 4∼8 m in height. It was ascertained that the kinematic GPS technology provides an efficient alternative to deformation monitoring by conventional means which are capable of detecting movements in the order of 5 mm.

  • PDF

Biomechanical Testing and Evaluation for Korean Badminton Shoes Project(I) (한국형 배드민턴화 개발을 위한 생체역학적 성능평가(I))

  • Park, Seung-Bum;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.149-157
    • /
    • 2009
  • The purpose of this project was to determine biomechanical differences between Type A(Korean brand) and Type B(world top brand) badminton shoes and to make recommendations to improve the fit and function of Type A badminton shoes. Measurements of shoe shape and dimensions, foot movement within the shoe, cushioning of ground reaction forces, in-shoe pressure and outsole traction were performed. In addition, subjective feedback of the fit and function of the shoes was quantified for 17 recreational badminton players. Type A shoe had a much higher heel and shallower heel cup, so the heel was not secured well in the shoe and the ankle joint was higher off the ground. Foot slippage was up to 40% greater in Type A shoe than Type B shoe. Impact forces and peak pressures under the foot were generally higher with Type A shoe compared to Type B shoe. The flexion axis of Type A shoe occurred in the midfoot, not at the ball of the foot like Type B shoe, where you would want the shoe flexion to occur. In summary, there are several characteristics where A Type shoe and B Type differ. Therefore, a few recommendations are provided to help improve the fit and function of A Type shoe.

Improvement of the HCM Delay Estimation Model for Exclusive Permitted Left Turns (비보호 좌회전 지체도 추정모형의 개선)

  • 김진태
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.2
    • /
    • pp.107-118
    • /
    • 2003
  • Highway Capacity Manual (HCM) provides an analytical delay estimation model to assist the evaluation of traffic at a signalized intersection. The model revised and included in the HCM published in the year 2000 reflects the results of recent studies and is utilized in various fields of transportation studies. For the implementation of the model in the case of permitted left turns, the HCM supplement provides a computational procedure to adjust the saturation flow rate of permitted left toms. The model however, is originally designed for a protected movement and thus underestimates the delay of permitted left turns due to its difference right-of-way nature. This document describes (1) a review of the theoretical background of the HCM delay estimation model, (2) problems embedded in the model for the delay estimation of permitted left turns, (3) a proposed model developed in this study to improve the delay estimation for permitted left turns and (4) a set of verification tests. In order to reflect various traffic and control conditions in the test, simulation studies were performed to by using the field data based on 120 different permitted left-turn scenarios. Comparison studies conducted between sets of delays estimated by the HCM and the proposed models against a set of the CORSIM delays and showed that the proposed model improved the estimation of the permitted left-turn delays. The explanatory variable of the relationship between the HCM delay and the simulation delay was 0.47 and the one between the delay estimated by the proposed model and the simulation delay was 0.77.

Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response (유전율에 의한 지반 매질내 유류침투거동 분석)

  • Kim Man-Il;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2005
  • For detecting a ground contamination survey, soil sampling method have been used a drilling or coring technique in general. However these methods are very difficult to systematically real-time monitoring of variation of contamination degree in field. ]'n this research frequency Domain Reflectometry (FDR) system was suggested and carried out to experimental approaches for determination of oil contamination on surface and underground. Experimental method using FDR method was discussed with feasibility of measurement in the laboratory column test. It is determined to degree of oil contamination due to response of dielectric constant re-lated with volumetric water content(θ/sub w/) and volumetric oil content( θ/sub al/ ) of saturated and unsaturated soil media. And physical properties such as effective porosity and oil residual ratio of saturated soil media were also measured through real-time monitoring works using installed FDR measurement sensors, which are defected characteristics of oil movement in the saturated soil media under the soil column tests. In the results of these experiments, a range of effective porosity was estimated to about 0.35 compared with initial porosity 0.40 of manufactured saturated soil media, which is also calculated to about 87.5% to the ratio of initial porosity to effective porosity. Finally oil residual ratio which is compared with volumetric water content and volumetric oil content was calculated about 62.5%.

A Development of Remote Bird Observation System Using FMCW RADAR (FMCW 레이더를 이용한 원격 조류(鳥類) 관측 시스템 개발)

  • Lee, Hee-Yong;Hwang, Hun-Gyu;Choi, Myung-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.247-256
    • /
    • 2014
  • Recently, camera and RADAR are used for more effective and accurate observation of the bird migration. In recent years, many researches on the bird migration using RADAR are undertaking and in active, thus causes the advent of "RADAR ornithology" as a new academic field. Due to the lack of accessibility, economic feasibility and mobility of weather RADAR, airport searching RADAR and tracking RADAR, Nowadays, a marine RADAR is widely used for a bird observation. In this paper, we deals with a study on development of a remote bird observation system using marine FMCW RADAR, which monitors, records and analyzes bird movement by RADAR image processing and target recognition technology. Also, we conduct first test and second test for availability of the developed system, and verify the system to apply in bird observation domain. Consequently, we figured problems out, and correct the problems to improve the system. The developed system can apply in other domains such as environment evaluation. In the future, the system needs to improve accuracy of statistics and to track migration route of bird.