• Title/Summary/Keyword: Movement Pattern

Search Result 1,146, Processing Time 0.029 seconds

Pattern Development using the Curvature Plot of 3D Human Scan Data (3차원 인체의 곡률분포를 이용한 패턴 전개)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.9
    • /
    • pp.1478-1486
    • /
    • 2008
  • The human body composed of concave and convex curvatures, and the current 3D scanning technology which involves inherent measurement errors make it difficult to extract distinct curvature plot directly. In this study, a method of extracting the clear curvature plot and its application to the cycling pants design were proposed. We have developed the ergonomic pattern from the 3D human body reflecting cycling posture. For the ergonomic design line on the 3D human body, the 3D information on the lower part of four male bodies with flexed posture was analyzed. The 3D scan data of four subjects were obtained using Cyberware. As results, the iteration of the tessellated shell was executed 100 times to obtain optimized curvature plots of the muscles on the body surface, and the boundaries of the curvature plots were applied to the design lines. Maximum(Max-pattern) and mean curvature plots(Mean-pattern) were adopted in the design line of the cycling pants, and performance of those lines was compared with that of conventional princess line(Con-pattern). The average error of total area and length in the 2D pattern developed from the 3D flexed body surface in this study were very minimal($4.58cm^2$(0.19%) and 0.15mm(0.46%)), which was within the range of tolerable limits in clothing production. The pattern obtained from the flexed body reflecting cycling posture already included the contraction and extension of the cycling skin, so that the extra ease for movement and good fit was not need to be considered.

What is the Most Effective Way to Facilitate the Abductor Hallucis Muscle during PNF Leg Pattern-Emphasized Hallux Abduction? (엄지발가락벌림을 강조한 PNF 다리패턴 시 엄지발가락벌림근을 활성화시킬 수 있는 가장 효과적인 방법은?)

  • Kim, Yong-Hun;Park, Du-Jin
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.97-106
    • /
    • 2020
  • Purpose: This study aimed to determine the most effective way to facilitate the abductor hallucis muscle during PNF leg pattern-emphasized hallux abduction. Methods: The study recruited 18 healthy adults. All participants agreed voluntarily to take part in the study following an explanations of its purpose and procedures. They randomly performed the PNF leg pattern-emphasized hallux abduction variations in a hook-lying or sitting position. Activation of the abductor hallucis (AbH), adductor hallucis (AdH), extensor hallucis longus (EHL), and tibialis anterior (TA) muscles, and the ratio of AbH/AdH, were measured during PNF exercises using electromyography. One-way repeated ANOVA was used to compare the activation of foot intrinsic and extrinsic muscles during the four PNF exercises. Results: PNF leg pattern-emphasized hallux abduction using normal timing was significantly higher in TA compared to PNF leg pattern-emphasized hallux abduction using timing for emphasis, regardless of the starting position. The PNF leg pattern-emphasized hallux abduction using timing for emphasis in the hook-lying position was significantly higher in AbH than in other exercises. Although there was no statistically significant difference in the ratio of AbH/AdH, it was higher in the hook-lying position. Conclusion: PNF leg pattern-emphasized hallux abduction using timing for emphasis in the hook-lying position can be recommended as a method to optimize the activation of AbH and the ratio of AbH/AdH.

Effects of Irradiation on the Muscle Activity Around an Amputation Site During Proprioceptive Neuromuscular Facilitation Pattern Exercise for Upper Extremity and Scapular Exercise on the Non-Amputated Part -A Case Study- (비 절단부에 적용한 PNF 상지 패턴과 견갑골 움직임에 의한 방산이 절단부 주변 근육 활성도에 미치는 영향 -단일 사례연구-)

  • Choi, Su-Hong;Rhee, Min-Hyung;Ha, Kyung-Jin;Lee, Sang-Yeol
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 2019
  • Purpose: This study verifies the muscle activity around the amputation site during proprioceptive neuromuscular facilitation (PNF) pattern exercise for the upper extremities on the non-amputated part in upper extremity amputees and provides basic data on effective exercise around an amputation site. Methods: Manual resistance was applied to the PNF upper extremity pattern of the non-amputated part to generate muscle activity around the amputation site. The resistance was adjusted to an intensity that could cause maximal isometric contraction. The muscle activity of the amputation site and the non-amputated part was measured using a surface electromyogram for the upper trapezius, middle trapezius, infraspinatus, serratus anterior, and pectoralis major. Results: During the scapular exercise in the painless range, the amputated side showed significantly lower muscle activity and a lower muscle contraction ratio compared with the non-amputated side. During the PNF pattern exercise in the painless range, the amputated side showed lower muscle activity and a lower muscle contraction ratio compared with the non-amputated side. When the direct scapular exercise of the amputated side was compared with the PNF pattern exercise of the non-amputated side, their muscle contraction ratios were similar. Conclusion: This study confirmed the effectiveness of the PNF pattern exercise of the non-amputated part as a way to indirectly train the injured site with no pain for rehabilitation of patients with serious body injuries, such as amputation. It is necessary to develop effective exercise programs for the rehabilitation of the amputation site based on the results of this study.

Implement pattern lock security enhancement using thread to measure input time (입력시간을 측정하는 쓰레드를 활용한 패턴 잠금 보안 강화 구현)

  • An, Kyuhwang;Kwon, Hyeokdong;Kim, Kyungho;Seo, Hwajeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.4
    • /
    • pp.470-476
    • /
    • 2019
  • The pattern locking technique applied to smart phones is a locking technique that many people use conveniently. However, the safety of pattern locking techniques is very low compared with other techniques. The pattern locking technique is vulnerable to a shoulder surfing attack, which is based on the user's input and can be interpreted by looking at the movement of the shoulder, and the smudge attack is also vulnerable due to fingerprint drag marks remaining on the mobile phone pad. Therefore, in this paper, we want to add a new security method to check the pressed time by using a thread in the pattern locking scheme to secure the vulnerability. It is divided into short, middle, and long click according to the pressing time at each point. When dragging using the technique, security performance enhances $3^n$ tiems. Therefore, even if dragging in the same 'ㄱ' manner, it becomes a completely different pattern depending on the pressing time at each point.

Effects of Skater and Sprinter Combined Pattern in PNF on Muscle Contraction Onset Time and Muscle Activation of Trunk Muscle (고유수용성신경근촉진법의 스케이터와 스프린터 통합패턴이 몸통근육의 근활성도와 근수축 개시에 미치는 영향)

  • Kim, Yoonhwan;Lee, Hyoungsoo
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.55-64
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the effect of the sprinter and skater combined patterns on muscle contraction onset time and muscle activation of body stabilizing muscles. Method : Our study included young and healthy men in their 20s. The participants used the sprinter and skater combined patterns of the proprioceptive neuromuscular facilitation (PNF) methods to measure muscle activation and muscle contraction onset time of the trunk muscles. To measure muscle contraction onset time and muscle activation, electrodes were attached to the rectus abdominis (RA), external oblique (EO), internal oblique (IO), and erector spinalis (ES) regions. Significant differences were identified using a paired t-test and a one-way analysis of variance (ANOVA) analysis. Result : In the sprinter combined pattern, the muscle with the fastest onset time of contraction was the RES, and that with the slowest was the RRA (p<.001). In the skater combined pattern, the muscle with the fastest onset time of contraction was the LES, and that with the slowest was the LRA (p<.001). In the sprinter combined pattern, the REO and LIO presented medium muscle contraction onset times (p<.001). In the skater combined pattern, the LEO and RIO presented medium muscle contraction onset times (p<.001). Conclusions: Based on these results, these patterns could be used as exercise methods for the elderly with delayed proactive response speeds of the body stabilization methods due to imbalances in body stabilizing muscles or limbs movement.

Calcium Movement in Carbachol-stimulated Cell-line (Calcium수송기전에 미치는 Carbachol의 영향)

  • Lee, Jong-Hwa
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.3
    • /
    • pp.355-363
    • /
    • 1995
  • It has been well known that the intracellular calcium concentration $([Ca^{2+}]_i)$ in living cell is very sensitive to live or to survive, but the transmembrane system of calcium ion, especially mechanism of calcium ion movement in unexcitable state has been little elucidated. Though many proposed theories for calcium ion transport have been reported, it is still unclear that how could the sustained maintenance in cytosolic calcium level be done in cell. Since one of possible mechanisms of calcium transport may be related to the acetylcholine receptor-linked calcium channel, author performed experiment to elucidate this mechanism of calcium influx related to cholinergic receptor in ml muscarinic receptor-transfected RBL-2H3 cell-line. 1) The effects of carbachol both on calcium ion influx and on the secretion of hexosaminidase were respectively observed in the manner of time-related or concentration-dependent pattern in this model. 2) The effects of several metal cations on calcium transport were shown in carbachol-induced cell-line. 3) Atropine was administered to examine the relationship between cholinergic receptor and calcium ion influx in this model. 4) PMA (Phorbol 12-myristate 13-acetate) or PTx (Pertussis toxin) was respectively administered to examine the secondary mediator which involved pathway of calcium ion movement in carbachol-induced cell-line. The results of this experiments were as follows; 1) Carbachol significantly stimulated both the calcium influx and the secretion of hexosaminidase in the manner of the concentration-dependent pattern. 2) Atropine potently blocked the effects of carbachol in concentration-response manner. 3) Administered metal cations inhibited the calcium influx in carbachol-stimulated this model to the concentration-related pattern. 4) PMA did not inhibit carbachol-induced secretion of hexosaminidase, but blocked the calcium influx in this cell-line. 5) The suppression of carbachol-induced hexosaminidase secretion was shown in PTx-treated cell -line.

  • PDF

THE CHANCE OF TOOTH NOBILITY FOLLOWING ORTHODONTIC TOOTH MOVEMENT : A SHORT-TERM STUDY (교정적 치아이동 후 치아동요도 변화에 관한 연구)

  • Hwang, Hyeon-Shik;Kim, Jae-Hyuk;Choi, Joon-Kyu;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.379-389
    • /
    • 1998
  • The purpose of the present study was to evaluate the change of tooth mobility following orthodontic tooth movement. Six orthodontic patients which had been treated with edgewise appliance were used. Tooth mobility was measured with Periostest at the time of the removal of orthodontic appliance and 1, 2, 3, 4, 6, 8, 10, 12, 16, 20, 24 weeks after appliance removal. Following results were obtained: 1. Tooth mobility upon the removal of orthodontic appliance showed individual variation while incisor showed greater mobility than the other teeth. 2. Tooth mobility showed continued decrease pattern until 24 weeks after appliance removal. 3. While maxillary incisors showed continued decrease pattern during the study period, the other teeth showed steep decline pattern during the first 12 weeks and gentle slope during the second 12 weeks. 4. The tooth mobility of the maxillary second premolar showed the most typical change in terms of the consistency of the decline. 5. There were no significant differences of tooth mobility between heavy- and light-contacted anterior teeth during experimental period. The results of the present study suggested that periodontal reorganization is not completed even in 24 weeks following orthodontic tooth movement.

  • PDF

Magnetic Guidance Vehicle using Up-and-down Rotating Type Differential Drive Unit (상하 회전형 차동 구동부를 이용한 자기 유도 무인운반차)

  • Song, Hajun;Cho, Hyunhak;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.123-128
    • /
    • 2014
  • This paper presents the study about MGV(Magnetic guidance vehicle) with up-and-down rotating type differential drive unit. Previous MGV needs the landmarks to get the driving information and additional sensor to recognize the landmarks except for localization sensor. Previous MGV requires at least 2 drive units when common fixed differential drive unit is used because it occurs the problems with driving control and localization error from imbalance of the MGV's weight. To solve such problems, we propose the MGV using up-and-down rotating type differential drive unit. Proposed MGV recognizes the driving information from the pattern which is consisted of both pole of magnet without landmarks and additional sensors, and it control the backward movement using up-and-down rotating type differential drive unit instead of common drive units. Proposed MGV considers KF(Kalman filter) to improve the localization accuracy. To verify the performance of proposed method, we designed MGV for the experiment. As the results, we can confirm the performance of propoesed method to recognize the pattern and to control the backward movement. With respect to localization, proposed method has the less RMSE about 5.6904 mm than previous method.

Frequent Origin-Destination Sequence Pattern Analysis from Taxi Trajectories (택시 기종점 빈번 순차 패턴 분석)

  • Lee, Tae Young;Jeon, Seung Bae;Jeong, Myeong Hun;Choi, Yun Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.461-467
    • /
    • 2019
  • Advances in location-aware and IoT (Internet of Things) technology increase the rapid generation of massive movement data. Knowledge discovery from massive movement data helps us to understand the urban flow and traffic management. This paper proposes a method to analyze frequent origin-destination sequence patterns from irregular spatiotemporal taxi pick-up locations. The proposed method starts by conducting cluster analysis and then run a frequent sequence pattern analysis based on identified clusters as a base unit. The experimental data is Seoul taxi trajectory data between 7 a.m. and 9 a.m. during one week. The experimental results present that significant frequent sequence patterns occur within Gangnam. The significant frequent sequence patterns of different regions are identified between Gangnam and Seoul City Hall area. Further, this study uses administrative boundaries as a base unit. The results based on administrative boundaries fails to detect the frequent sequence patterns between different regions. The proposed method can be applied to decrease not only taxis' empty-loaded rate, but also improve urban flow management.

Evaluation of the Movement Pattern of Squaliobarbus curriculus Inhabiting in the Mid-lower Part of Geum River Using Acoustic Telemetry (수중 음향 측정방식을 이용한 금강 중.하류의 눈불개 이동성 평가)

  • Yoon, Ju-Duk;Kim, Jeong-Hui;In, Dong-Su;Hwang, Eun-Ji;Yoon, Johee;Lee, Young-Joon;Chang, Kwang-Hyeon;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.4
    • /
    • pp.482-489
    • /
    • 2012
  • Visual monitoring is hard to apply on fish because they are living in a water system. To overcome this problem, acoustic telemetry, which is effective for underwater monitoring, is often used for studying fish behaviors, such as movement distance, route and patterns. In this study, in order to monitor the movement pattern of Squaliobarbus curriculus (family Cyprinidae), we used acoustic telemetry and identified the home range and movement distances. A total of nine individuals were released at two different locations: one is at the estuary barrage (Sc1~3) and the other is at the lower part of Baekjae Weir (Sc4~9), located in Geum River. Approximately, a 70 km section from the estuary barrage was investigated. Fish, which were released at the estuary barrage, utilized up to 12.7 km upstream as home range from the release site. At the lower part of Baekjae Weir, most of the fish moved and stayed within a 7.2 km downstream area, except for Sc6, which moved 53.4 km (linear maximum distance from release site) downstream from the release site. Relatively small sized fish (Sc7~9) did not show any movement. Accumulated movement distance significantly correlated with the standard length of S. curriculus ($r_s$=0.715, p=0.03). Moreover, the standard length of moving fish was significantly larger than that of not moving fish (Mann-Whitney U test, p=0.024). Therefore, the movement distance of S. curriculus has been correlated with fish size; movement distance was increased with the standard fish length. Although the sample size of monitored fish was small, various meaningful data were collected by acoustic telemetry. Consequently, this technique could be a method available for effectively monitoring the behavior and ecology of native Korean and endemic species.