• 제목/요약/키워드: Motor unit activation patterns

검색결과 5건 처리시간 0.019초

등장성 수축 결합기법의 특성에 대한 고찰 - 원심성 훈련의 중요성 - (Review of characteristics of the isotonic combination: Importance of eccentric training)

  • 김미현;배성수
    • PNF and Movement
    • /
    • 제2권1호
    • /
    • pp.25-33
    • /
    • 2004
  • Purpose : The purpose of this article is to summarize the characteristics of isotonic combination. Method : Some studies of the motor unit activation patterns during isometric, concentric, and eccentric actions, neural strategies in the control of muscle force, and concentric versus combined concentric-eccentric training were reviewed. Results & Conclusions : Eccentric torque may be relatively higher than concentric torque for two potential reasons: 1) stretch responses in the antagonist are not elicited to restrain the motion as can occur concentrically and 2) stretch responses in the agonist may augment eccentric torque production. Concentric-eccentric training has a greater influence on functional capacity than that of concentric training. Both maximal force and average force throughout the motion were significantly higher when the dynamic action was started with preactivation as compared to the mode without preactivation. The peak torques observed during the concentric phase of the eccentric-concentric muscle actions were higher than those noted in the pure concentric contraction.

  • PDF

뇌졸중 환자에서 운동단위의 초기 방전 양상 (Initial Motor Unit Discharge Pattern in Patients with Stroke)

  • 이상무;배재천
    • Annals of Clinical Neurophysiology
    • /
    • 제4권1호
    • /
    • pp.12-15
    • /
    • 2002
  • Background : Changes in firing pattern and in the recruitment order of single motor unit(MU) have been claimed to be characteristic of central motor lesions, and a reduced firing rate was found in upper motor neuron lesions. But these findings have been rarely studied before in Korea, so we studied initial MU recruitment pattern in stroke patients with hemiparesis. Methods : We studied six patients(3 men and 3 women) whose mean age was $60.6{\pm}7.4$ years. A mean $20.6{\pm}16.2$ months had elapsed since the stroke. To compare the initial MU activation patterns in proximal and distal segments of paretic limb with their contalateral unaffected counterparts, we studied the onset and recruitment intervals in biceps brachii(BB) and first dorsal interossei(FDI) muscles in paretic and healthy arms. In a single muscle we examined from 5 to 10 individual MUs. And in a single motor unit, both the onset interval and the recruitment interval was examined. Results : The mean onset interval in paretic limb was significantly(p<0.05) longer than unaffected limb at proximal and distal location: BB $118.5{\pm}17.8$ msec vs $96.1{\pm}8.3$ msec(n=58); FDI $125.8{\pm}16.7$ msec vs $101.5{\pm}17.2$ msec(n=38). The mean recruitment interval in paretic limb was also significantly(p<0.05) longer than unaffected limb: BB $87.7{\pm}14.9$ msec vs $73.4{\pm}11.5$ msec(n=53); FDI $96.3{\pm}16.4$ msec vs $87.7{\pm}14.1$ msec(n=38). Conclusion : The first recruited MU had a lower baseline firing rate and the second recruited motor unit potential appeared earlier in paretic than in healthy muscles. And these findings may explain one of the reasons for paresis in patients with stroke.

  • PDF

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

뇌 운동피질의 기능적 영상: 고식적 Gradient Echo기법과 EPI기법간의 비교 (Functional MR Imaging of Cerbral Motor Cortex: Comparison between Conventional Gradient Echo and EPI Techniques)

  • 송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.109-113
    • /
    • 1997
  • 목적: 고식적인 spoiled gradient echo(SPGR) 기법과 EPI기법간의 뇌의 운동피질에 대한 기능적 영상의 차이를 평가하고자 하였다. 대상 및 방법: 5명의 정상 성인을 대상으로 1.5T 자기공명영상기기에서 SPGR기법(TR/TE/flep angle=50ms / 40ms / $30^{\circ}$, FOV=300mm, matrix $size=256{\times}256$, 단면두께=5mm)과 기법(TR / TE / flip angle=3000ms / 40ms / $90^{\circ}$, FOV=300mm, matrix $size=128{\times}128$, 단면두께=5mm)을 사용하여 MR 에이터를 얻었다. EPI기법의 경우, 총 6개의 단면에 대해 총 960개의 영상을 얻었고 SPGR 기법 겨우, 위 6개의 단면 중 운동중추영역이 포함된 한 단면에 대해 총 160개의 영상을 얻었다. 사용된 paradigm은 각각 8번의 휴지 기간과 활성 기간으로 구성되었고 활성기간동안에 시행된 작업은 오른손 손가락의 쥠과 펼침 운동이었다. 뇌의 활성영역을 국소화 하기 위해 사용된 통게적인 처리방법은 cross-correlation 방법이었다. 두 기법의 활성화 영상에 대해 활성 영역에서의 휴지 기간과 활성 기간간의 신호 크기의 변화와 연속적인 MR 데이터의 신호 대 잡음비의 측정, 그리고 활성 영역의 위치와 그 범위를 비교 분석하였다. 결과: 두 기법 모두에서 운동중추영역인 전운동피질이 잘 관찰되었다. 휴지 기간과 활성 기간간의 신호 크기의 변화는 두 기법간의 유의한 차이가 없었다. 그러나, 연속적인 MR 데이터의 신호 대 잡음비에 있어서는 EPI 기법이 SPGR 기법보다 약 2배 높았다. 또한, 활성 영역에 있어서 EPI 기법이 SPGR기법보다 낮은 쪽으로의 p값의 분포를 보여 주었다. 결론: 본 연구는 운동중추영역에 대한 뇌의 기능적 영상을 얻는 데에 있어서 두 기법 모두 유용함을 보여주었다. 그러나, EPI 기법에서 얻을 수 있는 높은 신호 감도 특성에 의해 EPI 기법이 SPGR 기법보다 뇌의 기능적 영역에 대한 더 정확한 정보를 제공하는 장점을 지닌다.

  • PDF

무릎근력 지원용 모듈식 웨어러블 시스템 개발 (Development of a Modular-type Knee-assistive Wearable System)

  • 유승남;한정수;한창수
    • 대한인간공학회지
    • /
    • 제29권3호
    • /
    • pp.357-364
    • /
    • 2010
  • This study proposes a lower-limb exoskeleton system that is controlled by a wearer's muscle activity. This system is designed by following procedure. First, analyze the muscle activation patterns of human leg while walking. Second, select the adequate actuator to support the human walking based on calculation of required force of knee joint for step walking. Third, unit type knee and ankle orthotics are integrated with selected actuator. Finally, using this knee-assistive system (KAS) and developed muscle stiffness sensors (MSS), the muscle activity pattern of the subject is analyzed while he is walking on the stair. This study proposes an operating algorithm of KAS based on command signal of MSS which is generated by motion intent of human. A healthy and normal subject walked while wearing the developed powered-knee exoskeleton on his/her knees, and measured effectively assisted plantar flexor strength of the subject's knees and those neighboring muscles. Finally, capabilities and feasibility of the KAS are evaluated by testing the adapted motor pattern and the EMG signal variance while walking with exoskeleton. These results shows that developed exoskeleton which controlled by muscle activity could help human's walking acceptably.