• Title/Summary/Keyword: Motor grade

Search Result 144, Processing Time 0.025 seconds

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권3호
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

유도전동기의 구속운전에 따른 전기 및 발열 특성 연구 (A Study on the Electrical and Heat Generation Characteristics of an Induction Motor under Restrained Operation)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.25-33
    • /
    • 2023
  • In this study, we determined the failure rate and fire status of electric motors widely used in domestic and industrial devices and analyzed the associated fire risks by identifying the electrical and temperature characteristics of electric motors under the normal and restrained operation modes in industrial sites and laboratories. A 2.2kW motor used for driving a conveyor during the vulcanization process in a rubber product manufacturing plant was employed as the study object and was exposed to a high- temperature environment as this motor is widely used in industrial sites. The current amplitude was 4.45-4.50 A during normal operation and 38.2-41.5 A during restrained operation due to the pinching of products and semi-finished products (i.e., 8.5 times higher than that during normal operation). The leakage current amplitude was 0.33 mA during both operation modes. The temperature of the workplace in summer was 42.38℃, indicating a poor environment for the installed motor. In the laboratory, the current and temperature of the coil inside a 3.7kW motor were measured under the restrained operation mode as performing measurements of the coil inside the motor in industrial sites is challenging. The current amplitude during normal operation was 3.5 A, whereas that during restrained operation for 30 s was 51.7-58.6 A, which is 14.8-16.7 times higher than that of normal operation. Moreover, the temperature of the motor coil increased from 22.9℃ to 101℃. Based on the experimental data, we derived the temperature increase formula according to the restrained operation time by performing a regression analysis and verified the time at which the temperature exceeded the stipulated limit for the insulation grade. The findings presented in this paper can be utilized to establish fire-prevention measures and perform safety management of motors of the same type or with a similar capacity.

고유-전정감각 중심의 감각통합 중재가 초등학교 저학년 아동의 글씨쓰기와 소운동에 미치는 영향 (The Effect of Sensory Integrative Intervention Focused on Proprioceptive-Vestibular Stimuli on the Handwriting and Fine Motor Function in Lower Grade Elementary School Children)

  • 황지혜;김희정;정혜림
    • 대한감각통합치료학회지
    • /
    • 제15권1호
    • /
    • pp.10-20
    • /
    • 2017
  • 목적 : 본 연구는 고유-전정감각 중심의 감각통합 중재가 초등학교 저학년 아동의 글씨쓰기와 소근육 능력 향상에 영향을 미치는지 알아보고자 하였다. 연구방법 : 본 연구는 부산 소재 초등학교에 재학 중인 저학년 아동 8명을 대상으로 단일집단 사전-사후 설계(one group pretest-posttest design)를 사용하였다. 2016년 5월에서 10월까지 주 2회, 총 14회기의 고유-전정감각 중심의 감각통합중재를 실시하였으며 글씨쓰기와 소근육 능력에 대한 측정은 한글자모쓰기검사와 Bruininks-Oseretsky Test of Motor Proficiency (BOTMP)의 Fine motor영역 검사를 실시하였다. 결과 : 중재 후 한글자모쓰기검사 결과 자음쓰기와 전체 총점은 통계적으로 유의한 차이를 나타냈으며 모음쓰기는 통계적으로 유의한 차이는 없었으나 점수의 향상을 나타내 글씨쓰기 능력의 향상을 나타냈다. BOTMP-Fine motor결과 Response Speed항목은 통계적으로 유의한 차이를 나타냈으며 Visual-Motor control항목은 중재 전후로 점수의 증가가 있었으나 통계적으로 유의한 차이는 없었다. 결론 : 본 연구는 고유-전정감각 중심의 감각통합 중재가 초등학교 저학년 아동의 글씨쓰기와 소근육 능력 향상에 긍정적 영향을 미치는 것을 확인하였다.

철도건널목 사고방지를 위한 지능화 방안 연구 (Accident prevention and damage reduction technology development through intelligence of Highway-railroad grade crossing)

  • 조봉관;류상환;황현철;조흥식;이호용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.175-177
    • /
    • 2008
  • The level crossing collision accident which comprises more than 90 percent of all level crossing accidents is one of the most serious safety problems. There is a critical need for providing safe strategy and is focusing on the level crossing information rather than measures at a grade crossing. This study is intended to develop technology for accident prevention and damage reduction based on accident cases analysis result and improvement direction to complement shortcomings of safety equipment of conventional level crossing and to establish safety of travelers(train, motor vehicle, person).

  • PDF

한방병원에 입원한 뇌경색 환자의 기능회복과 관련된 특성에 대한 연구 (The Study about Characteristics Affecting Functional Recovery of Stroke Patients Treated in an Oriental Medical Center)

  • 김영지;김미영;이승엽;최원우;박주영;권승원;정우상;문상관;조기호;김영석;박성욱;박정미;고창남;배형섭;나병조
    • 대한한방내과학회지
    • /
    • 제30권4호
    • /
    • pp.719-731
    • /
    • 2009
  • Objectives : Stroke is the most common disabling neurological disease of adult life. The treatment and rehabilitation of stroke patients is an important and challenging area in the field of medicine. In Korea, a lot of stroke patients are treated using oriental medicine and there have been reports on their functional recovery. The aim of this study was to prove the therapeutic effect of oriental medicine on ischemic stroke. We also tried to identify characteristics of patients whose functional recovery was prominent and studied whether or not the use of fluids, anticoagulants, antiplatelets and neuroprotective agents increased the functional recovery of patients. Methods : We studied 794 patients within 2 weeks after first attack of ischemic stroke who were admitted to Kyung-Hee Oriental Medical Center from 1999 to 2000. Their maximum admission period was 60 days. Results : Motor power grade, NIHSS and MBI scores of patients improved during hospitalization significantly. Factors affecting functional recovery were admission period, motor power grade, NIHSS and MBI at admission. Age, waist-hip ratio and HDL cholesterol also affected functional recovery of patients. Whether or not fluids, anticoagulants, antiplatelets and neuroprotective agents were administered had nothing to do with functional recovery. Conclusion : Oriental medicine is effective for treatment and rehabilitation of ischemic stroke patients. When we manage stroke, we have to consider some important factors.

  • PDF

A Novel Efficiency Optimization Strategy of IPMSM for Pump Applications

  • Zhou, Guangxu;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.515-520
    • /
    • 2009
  • According to the operating characteristics of pump applications, they should exhibit high efficiency and energy saving capabilities throughout the whole operating process. A novel efficiency optimization control strategy is presented here to meet the high efficiency demand of a variable speed Permanent Magnet Synchronous Motor (PMSM). The core of this strategy is the excellent integration of mended maximum torque to the current control algorithm, based on the losses model during the dynamic and the grade search method with changed step by fuzzy logic during the steady. The performance experiments for the control system of a variable speed high efficiency PMSM have been completed. The test results verified that the system can reliably operate with a different control strategy during dynamic and steady operation, and the system exhibits better performance when using the efficiency-optimization control.

연속주조기에서 Driven Roll Motor의 Load Sharing 제어 (Load Sharing Control of Driven Roll in Continuous Caster)

  • 천창근;신건;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.715-718
    • /
    • 2002
  • As the modern technology of continuous casting plant is focused on improvement of slab quality, the control system of strand driven roll which has positive effect is investigated in this paper. An irregular distribution of withdrawal force gives rise to horizontal crack in high and middle grade carbon steel. Based on the basic understanding on design concept of high technology company, monitoring the withdrawal force distribution of strand driven roll and analysis of the control system was Performed at continuous casters of POSCO. The control algorithm of withdrawal force distribution for A.C motor vector control, which was derived from above study and had been applied for POSCO Kwangyang 1-4 continuous casting plant, is presented.

  • PDF

SMART 연구로 주냉각재펌프의 검증시험 (Qualification Test of a Main Coolant Pump for SMART Pilot)

  • 박상진;윤의수;오형우
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

퍼지추론을 이용한 전동기구동 펌프시스템의 고장진단 (Fault Diagnosis of motor driven pump system based on fuzzy inference)

  • 조윤석;류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.689-691
    • /
    • 1995
  • In this paper, a fault detection and isolation unit(FDIU) for a centrifugal pump system driven by DC-motor is proposed. The proposed scheme can be classified into the dedicated observer scheme(DOS). A fuzzy logic based inference engine is adopted for the isolation of each faults. Having the fuzzy inference engine, the proposed FDIU resolve a few important problems of the conventional DOSs with conventional two valued logic. The ouputs of the proposed FDIU are not "ith fault occurred" but the grade of memberships that indicate the consistency of observered symptoms(residuals) with each fault symptoms stored in the rule base. The ouputs can easily be transferred to the ranking of the fault possibilities and it will provide very useful informations in monitoring the process. The simulation results show that the FDIU has very good diagnostic ability even in the noisy environment.

  • PDF

Posterior Interbody Fusion using Cage for T4 Bursting Fracture

  • Kim, Seok-Won;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권5호
    • /
    • pp.389-391
    • /
    • 2005
  • We report a case of T4 bursting fracture with paraparesis that recovered by posterior approach. A 47-year-old man presented with paraparesis (grade III) which had progressed rapidly after motor cycle accident. After sacrificing the T4 nerve root (right), posterior interbody fusion using cage following T4 corpectomy and T3-4, T4-5 discectomy was performed. After operation, lower extremities motor power improved and he could walk after one month. And this is the first report of posterior approach using cage by corpectomy and two level discectomy in case of upper thoracic burst fracture in Korea.