• Title/Summary/Keyword: Motor Aging

Search Result 124, Processing Time 0.028 seconds

Development of the Auto-Aging Test Controller for a Hydraulic Motor (유압모터 길들이기 자동시험 제어기 개발)

  • Jung, Gyu Hong;Shin, Dae Young;Seo, Dong Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.28-34
    • /
    • 2015
  • Because heavy-duty construction vehicles such as excavators are required for good engine-room cooling capacity, a hydraulic gear motor is adopted in the cooling fan drive mechanism to actively control the output speed, instead of adopting the conventional ON/OFF type belt drive. While gear motors are normally limited to 140bars of operating pressure, those for the cooling fan are capable of operating at continuous pressures of up to 220bars. After assembly, all gear motors for high pressure must pass an aging test which is a kind of the wearing process between the gear teeth and motor housing. During the aging process with gradual pressure increments, gear sticking sometimes occurs due to abnormal wear, resulting in defects. This paper focuses on a gear-sticking free aging test controller that is designed together with the knowledge of an experienced operator and the analysis results of experimental data of the gear jamming phenomenon. From the aging experiment, it is demonstrated that the developed controller that can alter the setting pressure of the load pump is effective for stabilizing the abrupt increase in the motor input pressure, thus preventing the hydraulic motor from stopping. This is expected to be helpful for the reduction of defects and increase in productivity.

Change of Insulation Properties of Stator Coil fed by Inverter Source on Traction Motor (인버터 전원에 의한 견인전동기 고정자 코일의 절연특성 변화)

  • Jang, Dong-Uk;Park, Hyun-June;Lee, Gil-Hun;Choi, Jong-Sun;Lee, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.420-422
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper Presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging,. and the rate of which aging is taking pace. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and Predict the life of the traction motor in EMU.

  • PDF

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 전기적 열화특성)

  • Park Hyun-June;Jang Dong-Uk;Kim Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.623-627
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.

  • PDF

Properties of Electrical Performance by Inverter Surge on Stator Coil of Traction Motor (인버터 서지에 의한 견인전동기 고정자 권선의 전기적 특성 변화)

  • Park, Hyun-June;Jang, Dong-Uk;Choi, Nam-Ho;Choi, Jong-Sun;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1285-1287
    • /
    • 2003
  • The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking. the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss($tan{\delta}$), capacitance and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor.

  • PDF

A Study on the Condition Diagnosis for the Stator Coil of Traction Motor by Transient Surge (과도서지에 의한 견인전동기 고정자 코일의 상태진단 연구)

  • 박현준;장동욱;김길동;최종선;김정수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.247-252
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss(tan $\delta$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge (과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화)

  • 박현준;장동욱;이길헌;최종선;김저우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

Properties of Thermal Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 열적 열화특성)

  • Park Hyun-June;Lee Chang-Moo;Lee Han-Min;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.606-610
    • /
    • 2003
  • The 200 class insulation system which adopted to traction motor have excellent dielectric strength but weaken to thermal stress therefore deterioration phenomena analysis according to thermal stress is necessary. Accelerated thermal aging tests have been used to determine thermal reliability of stator coils used as traction motor in electric multiple unit. The conventional aging test is carried on according to IEC 60034-18-31 and IEEE Std. 275-1992. Variation in insulation resistance, P.I, capacitance, dielectric loss($tan{\delta}$) and partial discharge are measured during the aging cycle. Sample coils for traction motor were tested by accelerated aging test which composed of heat, vibration and moisture. Reliability and expected life were evaluated on the insulation system for traction motor.

  • PDF

Fault Diagnosis System for Traction Motor in Electric Multiple Unit (전동차 견인전동기 고장진단시스템)

  • Park, Hyun-June;Jang, Dong-Uk;Lee, Gil-Hun;Choi, Jong-Sun;Kim, Jung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.518-521
    • /
    • 2003
  • A new measurement system was developed by fault diagnosis system for traction motor using current signal analysis. The motor current signature analysis method is used for traction motor fault diagnosis. The diagnosis system program is constructed by artificial neural networks algorithm, those results from the program are used to train neural networks. The trained neural networks have the ability to compute adaptive results for non-trained inputs, and to calculate very fast due to original parallel structure of neural networks with high accuracy within destined tolerance. This system suggested that available test for checking, the probable extent of aging, and the rate of which aging is taking place.

  • PDF

Physiological Changes with Aging (노화(Aging)에 따른 생리학적 변화)

  • Kim Suhn-Yeop;Yi Seung-Ju
    • The Journal of Korean Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.79-87
    • /
    • 1993
  • The purpose of this literature review was to identify the physiological changes with aging. The results of this renew were to follows : We have seen a wide variety of such changes in the cells and in all organ systems. 1. At least 40 percent of people over 65 will die of cardiac disease, 15 percent of cerebrovascular disease, and possibly another 5 percent of other types of vascular impairment. 2. The increase rigidity of the thoracic wall and the decreased strength of the expiratory muscles decrease the propulsive effectiveness of the cough. 3. The density of capillaries per motor units is decreased. 4. Starting before age 40 in both sexes there is a shift from an increase in bone mass to a progressive decrease. 5. Histologic studies show a lim age-correlated decrease in the number of Pacini's. Merkel's, and Meissner's corpuscles.

  • PDF

Natural Aging Properties Analysis of HTPB Propellant (HTPB계 고체추진제의 자연노화 물성 분석)

  • Park, Jung-Ho;Ryu, Nam-Sun;Park, Jae-Beom;Jung, Gyoo-Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • Hydroxy-terminated polybutadiene (HTPB) propellants of solid rocket motors age differently under different storage temperatures. The shelf life of a solid rocket motor depends on the aging ratio of the HTPB propellant; it can be estimated through the viscoelastic properties by an aging test. This study analyzed the initial and natural aging properties during long-term storage. The initial properties were obtained from characterization and accelerated test results. The test results were obtained by analyzing the strain on cylindrical grains when a thermal load was applied.