• Title/Summary/Keyword: Motion distance

Search Result 975, Processing Time 0.026 seconds

Effect of Shoes Sole Form on Knee and Ankle Muscle Activity (신발 밑창 형태가 무릎 및 발목 근육의 근활성화에 미치는 영향)

  • Yoon, Se-Won;Lee, Jeong-Woo;Choi, Mung-Sim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.347-354
    • /
    • 2014
  • PURPOSE: This study was to examine changes in muscle activity of lower extremity shoes sole form (high heels, shoes with curved out sole, house shoes). METHODS: The subjects of this study were 12 women in their twenties. They put three kinds of shoes (high heels, shoes with curved out sole, house shoes) and walked 5m. The muscles activities of lower extremity muscles (rectus femoris, vastus medialis, tibialis anterior, gastrocnemius medial part) were measured using a wireless electromyogram (EMG). Rectus femoris was attached to 1/2 position at the distance between ASIS and knee bone and vastus medials was attached to 2cm from upper inside of knee bone. Tibialis anterior was attached to 75% position above line connecting knee joint and ankle joint and gastrocnemius medial part was attached to 3 5% position above knee joint and ankle. RESULTS: It was found that there were significant differences in changes of muscles activities of lower extremity muscles (rectus femoris, vastus medialis, tibialis anterior, gastrocnemius medial part) on shoes sole forms (p<.05). All lower extremity muscles were showed high muscles activities, when high heels wear (p<.05). Wearing shoes with curved out sole was showed high muscle activity of tibialis anterior and lower muscle activity of gastrocnemius medial part compared with wearing house shoes (p<.05). CONCLUSION: Shoes sole form should be considered when patients with knee and ankle joint problems choose shoes because muscles were showed different activities according to shoes sole forms.

The Ground Checkout Test of OSMI(Ocean Scanning Multispectral Imager) on KOMPSAT-1

  • Yong, Sang-Soon;Shim, Hyung-Sik;Heo, Haeng-Pal;Cho, Young-Min;Oh, Kyoung-Hwan;Woo, Sun-Hee;Paik, Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.375-380
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the KOMPSAT satellite to perform worldwide ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a wisk-broom motion with a swath width of 800 km and a ground sample distance (GSD) of<1km over the entire field of view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data compression/storage. The instrument also performs sun and dark calibration for on-board instrument calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400nm to 900nm using CCD Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands. KOMPSAT satellite with OSMI was integrated and the satellite level environment tests and instrument aliveness/functional test as well, such as launch environment, on-orbit environment (Thermal/vacuum) and EMl/EMC test were performed at KARI. Test results met the requirements and the OSMI data were collected and analyzed during each test phase. The instrument is launched on the KOMPSAT satellite in the late 1999 and the image is scheduled to start collecting ocean color data in the early 2000 upon completion of on-orbit instrument checkout.

  • PDF

The star catalogue in Seonggyeong - Comparison with the modern Hipparcos Catalogue

  • Kim, Dong-Bin;Kim, Chun-Hwey;Lee, Yong-Sam
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.19.2-19.2
    • /
    • 2011
  • In 1861 Nam Byeong-Gil published a book called as "Seonggyeong" which contains a star catalogue (NBGC) with the positions, magnitudes, and star maps for 1449 stars. The NBGC lists only the traditional Chinese stars selected from "the sequel to the Qing Dynasty Star Catalogue and Star Map." To identify each star from the NBGC with modern counterpart, we correct the positions of the Hipparcos stars brighter than 6.5 mag for proper motion, then precess the coordinates to the epoch of the NBGC. For each star in the NBGC, we find the nearest counterpart in the Hipparcos Catalogue (HC). If a much brighter star is at a slightly larger angular distance, we select that star as the secure counterpart. As a result, 95.5% of the stars in the NBGC were identified. We find a very good overall agreement of our results with a previous analysis by Ahn et al. (1996, Journal of the Korean History of Science Society, vol. I). For securely identified stars, we analyse its accuracy on the basis of comparison with data from the HC. The correlation of the errors between right ascensions and declinations is significantly deviated from spherical distribution. The magnitudes recorded in the NBGC correlate well with modern values. The accuracy of position decreases slowly with magnitude. Right ascensions and declinations have error distributions with ${\sigma}$ = 2.0' for the former while the latter with ${\sigma}$ = 1.6', but with much more errors >5' than expected for a Gaussian distribution.

  • PDF

ANALYSIS OF CLINICAL EFFECT OF $CO_2$ LASER ILLUMINATION AFTER SURGICAL EXTRACTION OF IMPACTED 3RD MOLAR (하악 매복치 발치 후 $CO_2$ laser 조사의 임상적 효과 분석)

  • Kim, In-Soo;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.349-352
    • /
    • 2001
  • Dental laser provides many advantages to the clinicians. Those are excellent hemostatic effect, good operating sight, minimal adjacent tissue injury, reduction of postoperative swelling & pain, reduction of postoperative infection, reduction of scar tissue & contraction, etc. The purpose of this study is to observe how these advantages work after surgical extraction of impacted third molar. From march 2000 to july 2000, we have randomly divided the patients who had been surgically extracted unilateral impacted third molar into two groups. The first group comprised $CO_2$ laser illumination with 3 watts, defocusing & continuous mode, rotating motion for about 3 minutes after finishing of surgical extraction & suture. The other group patients were not irradiated. The medications in two groups were same. We measured pain, swelling and trismus three times(pre-operation, first day after operation, and 7th day after operation). The number of the patients who had measured three times all are 64, laser irradiated groups are 36 and non-irradiated groups are 28. The age ranged from 19 to 50, with a mean of 27.9 years. The operative time ranged from 3 minutes to 50 minutes, with a mean of 12.1 minutes. In the $CO_2$ laser group, the pain intensity of the 7th day after operation was still increased significantly comparing with that of the pre-operation and the distance which were measured for the swelling was different significantly. In the other group, the mouth opening limitation was still decreased significantly.

  • PDF

Damped Oscill ations of the (Hard)Contact Lenses Posterior to the Blink (순목 후 콘택트(하드)렌즈의 감쇄 진동)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.173-184
    • /
    • 2005
  • A capillary action-induced tension develops in the tear layer between the contact lens and cornea, which leads to the restoring force due to difference in the layer thickness between either upper and lower or left and right side of the lens when it is displaced off the equilibrium position as a result of blinking. Suppose the lens was displaced a certain distance from the equilibrium position, lens starts to oscillate toward the equilibrium position with the decreasing amplitude due to the restoring force as well as the velocity dependent viscous damping force in the tear layer. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped oscillations of lenses. The model predicts the time dependence of lenses after the blink varying the various parameters such as Be, diameters, masses and positions displaced from equilibrium. As the Be and mass of lens increases the rate of amplitude reduction decreases, which requires a more time for the lens to return to the equilibrium position. It seems that varying the lens' displacement and diameters affect the lens' motion very little.

  • PDF

Observation of Semi-diurnal Internal Tides and Near-inertial Waves at the Shelf Break of the East China Sea

  • Park, Jae-Hun;Lie, Heung-Jae;Guo, Binghuo
    • Ocean and Polar Research
    • /
    • v.33 no.4
    • /
    • pp.409-419
    • /
    • 2011
  • Semi-diurnal internal tides and near-inertial waves are investigated using moored current meter measurements at four sites along the shelf break of the East China Sea during August 1987 and May-June 1988. Each mooring is equipped with four current meters spanning from near surface to near bottom. Spectral analyses of all current data reveal dominant spectra at the semi-diurnal frequency band, where the upper and lower current measurements show out-of-phase relationship between them with significant coherences. These are consistent with typical characteristics of the first-mode semi-diurnal internal tide. Strong intensification of the near-bottom baroclinic currents is observed only at one site, where the ratio of the bottom slope to the slope of the internal-wave characteristics at the semi-diurnal frequency is close to unity. An energetic near-inertial wave event is observed during the first half of May-June 1988 observation at two mooring sites. Rotary spectra reveal that the most dominant signal is clockwise rotating motion at the near-inertial frequency band. Upward phase and downward energy propagations, shown in time-depth contour plots of near-inertial bandpass filtered currents, are confirmed by cross correlations between the upper- and lower-layer current measurements. The upward-propagating phase speed is estimated to be about 0.13 cm $s^{-1}$ at both sites. Significant coherences and in-phase relationships of near-inertial currents at the same or similar depths between the two sites are observed in spite of their long distance of about 110 km.

Effects of Therapeutic Exercise on Posture, Pain and Asymmetric Muscle Activity in a Patient with Forward Head Posture: case report (치료적운동이 전방두부자세 환자의 자세, 통증 및 비대칭적 근육활성에 미치는 영향: 증례보고)

  • Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.1
    • /
    • pp.71-82
    • /
    • 2016
  • PURPOSE: The purpose of this case report was to determine the effect of therapeutic exercise on posture, pain, and muscle activity in two patients with forward head posture (FHP). METHODS: A-31-year-old male (patient A) and a 19-year-old women (patient B) presented with FHP, neck pain, and headache. The therapeutic exercise program consisted of cervical mobilization, deep cervical flexors strengthening, and cervical extensors stretching, for 40 min/d, 2 d/week, for 8 weeks. Neck pain (VAS), neck disability (NDI), cervical range of motion (CROM), lateral view of cervical spine X-ray (indicating the FHP), and asymmetrical neck and shoulder muscular activity ratio were measured before, after 4 weeks, and after 8 weeks of corrective exercise. RESULTS: VAS and NDI decreased in patients A and B after exercise compared to before the program. CROM increased in patients A and B at flexion, extension, side bending, and rotation after exercise compared to before the program. FHP decreased in patients A and B at distance after exercise compared to before the program. In addition, asymmetrical neck and shoulder muscles activity ratio improved in patients A and B after exercise compared to before the program. CONCLUSION: We demonstrated in a case report that therapeutic exercise increases ROM, decreases pain and disability of neck, FHP, and asymmetry muscle activity ratio in patients with FHP. These finding have clinical implications for therapeutic exercise in patients with FHP.

Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units (Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교)

  • Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources (치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교)

  • Kim H.;Lee K.Y.;Park S. H.;Jung I. Y.;Jeon S. B.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

Spatial Experience and Design Method in the Installation Projects of Olafur Eliasson - Focusing on Relationship between Human and Surrounding - (올라퍼 엘리아슨의 설치 작품에 나타난 공간 경험 및 디자인 방법 - 인간, 환경 사이의 관계성을 중심으로 -)

  • Lee, Song-Hak;Kim, Jong-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.33-40
    • /
    • 2014
  • The Danish-Icelandic artist, Olafur Eliasson who was born in 1967 is known for installation projects employing materials such as colour, fog, mirror and light to rethink the relationship between human and surrounding. Since he started the early projects, Eliasson has been interested in the relationship between an art, a viewer and space. He has used the medium from nature because he thought nature is very common subject to derive new idea of relationship between human and surrounding. Eliasson revealed the idea of relationship between human and surrounding by three characteristics of spatial design such as 'reinterpretation of placeness by juxtaposition of mediums and defamilarization', 'ambiguity and extensity of depth distance of space by mediums' and 'change in spatiality by movement of viewers and time'. This paper focused on four case projects : The mediated motion in 2001, The weather project in 2003, The blind pavilion in 2003, Your rainbow panorama in 2011. It is aimed to discover relationship between human and surrounding in the case projects under three characteristics. This study found that three characteristics were differently applied in the case projects in terms of spatial experience and design methods. Inside & outside locations, formal quality, visual-perceptual relationships in and around each case are crucial elements and tools. The unique relationship between human and surrounding of Eliasson and three characteristics are applicable to architecture and spatial design.