• Title/Summary/Keyword: Motion analysis system

Search Result 2,499, Processing Time 0.027 seconds

Design and Implementation of the Golf Swing Analysis System through Captured Motion Picture (골프 동작 분석을 위한 동영상 편집시스템 설계 및 구현)

  • Park, Young-Bom
    • The KIPS Transactions:PartB
    • /
    • v.9B no.4
    • /
    • pp.453-458
    • /
    • 2002
  • It is not easy to analyze dynamic sports motion, but it can be done easily by using an interactive playback of the recorded motion. Everybody is able to capture a golf swing owing to the popularization of PC and digital camcorder in these days. In this study, the system that can provide golf swing analysis is selected and implemented. Furthermore, editing method that can represent motion is applied and moving object tracking algorithm that can make this profess easy is applied to provide easy golf swing analysis.

Dynamics Analysis of a Small Training Boat ant Its Optimal Control

  • Nakatani, Toshihiko;End, Makoto;Yamamoto, Keiichiro;Kanda, Taishi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.342-345
    • /
    • 2005
  • This paper describes dynamics analysis of a small training boat and a new type of ship's autopilot not only to keep her course but also to reduce her roll motion. Firstly, statistical analysis through multi-variate auto regressive model is carried out using the real data collected from the sea trial on an actual small training boat Sazanami after the navigational system of the boat was upgraded. It is shown that the roll motion is strongly influenced by the rudder motion and it is suggested that there is a possibility of reducing the roll motion by controlling the rudder order properly. Based on this observation, a new type of ship's autopilot that takes the roll motion into account is designed using the muti-variate modern control theory. Lastly, digital simulations by white noise are carried out in order to evaluate the proposed system and a typical result is demonstrated. As results of simulations, the proposed autopilot had good performance compared with the original data.

  • PDF

Numerical Analysis of Offshore Installation Using a Floating Crane with Heave Compensator in Waves (Heave Compensator를 고려한 파랑 중 해상 크레인 설치작업 수치해석)

  • Nam, Bo-Woo;Hong, Sa-Young;Kim, Jong-Wook;Lee, Dong-Yeop
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.70-77
    • /
    • 2012
  • In this study, a numerical analysis of offshore installation using a floating crane with heave compensator is carried out in time domain. The motion analysis of crane vessels is based on floating body dynamics using convolution integral and the crane wire is treated as simple spring. The lifted structure is assumed as a rigid body with 3 degree-of-freedom translational motion. The heave compensator is numerically modelled by the generalized spring-damper system. Firstly, forced motion simulations of crane wire system are carried out to figure out the basic principle of heave compensator. The transfer function of crane wire system is obtained and effective wave period of heave compensator are found. Then, coupled analysis of crane vessel, crane wire, and lifted structure are performed in regular and irregular sea conditions. Two different crane vessels and two lifted structures (suction pile and manifold) are considered in this study. Through a series of numerical calculations, the effective zone of heave compensator is investigated with respect to wave period and crane wire length.

Emulation of Anti-alias Filtering in Vision Based Motion Mmeasurement (비전 센서의 앨리어싱 방지 필터링 모방 기법)

  • Kim, Jung-Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.6 no.1
    • /
    • pp.18-26
    • /
    • 2011
  • This paper presents a method, Exposure Controlled Temporal Filtering (ECF), applied to visual motion tracking, that can cancel the temporal aliasing of periodic vibrations of cameras and fluctuations in illumination through the control of exposure time. We first present a theoretical analysis of the exposure induced image time integration process and how it samples sensor impingent light that is periodically fluctuating. Based on this analysis we develop a simple method to cancel high frequency vibrations that are temporally aliased onto sampled image sequences and thus to subsequent motion tracking measurements. Simulations and experiments using the 'Center of Gravity' and Normalized Cross-Correlation motion tracking methods were performed on a microscopic motion tracking system to validate the analytical predictions.

Swing Motion of Miniaturized Humanoid Robot (소형 휴머노이드 로봇의 그네 운동)

  • 이수영;정길도;성영휘;박성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.267-272
    • /
    • 2004
  • In this Paper, we present analysis on the dynamics of human swing and its realization by a miniaturized humanoid robot. Since the motion of legs is the most important in the swing, the swing system can be approximated as a double pendulum. Based on Lagrangian analysis, the leg motion is designed to make the swing motion as sustained oscillation. In order to detect the peak instant of the swing and to synchronize the leg motion with the swing, we use ADXL acceleration/inclination sensor. The miniaturized humanoid in this paper has total 20 DOFs including 6 DOFs in each leg, 34cm in height, and 2kg in weight. As a result of realization of the swing by the humanoid, the sustained oscillation is verified through experiments.

A Numerical Simulation for Contractive and Dilative Periodic Motion on Axisymmetric Body

  • Kim, Moon-Chan
    • Journal of Ship and Ocean Technology
    • /
    • v.3 no.1
    • /
    • pp.1-11
    • /
    • 1999
  • Numerical simulation for the axisymmetric body with contractive and dilative periodic motion is carried out. The present analysis shows that a propulsive force can be obtained in highly viscous fluid by the contractive and dilative motion of axisymmetric body. An axisymmetric code is developed with unstructured grid system for the simulation of complicated motion and geometry. It is validated by comparing with the results of Stokes approximation with the problem of uniform flow past a sphere in low Reynolds number($R_n$ = 1). The validated code is applied to the simulation of contractive and dilative periodic motion of body whose results are quantitatively compared with the two dimensional case. The simulation is extended to the analysis of waving surface with projecting part for finding out the difference of hydrodynamics performance according to variation of waving surface configuration. The present study will be the basic research for the development of the propulsor of an axisymmetric micro-hydro-machine.

  • PDF

Analysis for Angle, Center of Mass and Muscle Activity on Good and Bad Motion of the Pirouette in Ballet (발레 삐루엣 동작 수행정도에 따른 각도, 중심변인 및 근활동 분석)

  • Kwon, An-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.2
    • /
    • pp.181-187
    • /
    • 2011
  • The purpose of this study was to identify major factors on pirouette in ballet, and especially angle, Center of Mass(CM) & muscle activity aspects. The data were collected by using Motion Analysis System with 12 cameras to analyze kinematic variables with 120 Hz and Electromyography(EMG; 4,000 Hz) & Force Platform(1,000 Hz) to analyze kinetic variables. The subjects of this study were 8 female ballet dancers. The results as follow. First of all, full extension of knee joint and full plantar flexion of ankle joint appeared at the similar point. Secondly, in the rotational phase, total movement of segments in Good motion is smaller than that of Bad motion(in Good motion, head movement 2.70 cm, right shoulder movement 0.72 cm, left shoulder 4.26 cm, left wrist 17.4 mm smaller than Bad motion). Third, CoP distance of Good motion is 11.76 mm, and CoP distance of Bad motion is 11.76 mm, so Good motion is 5.98 mm smaller). Lastly, Pirouette need more retus femur activity than gastrocnemius activity in extention phase and rotation phase of support leg.

Total Dynamic Analysis of Deep-Seabed Integrated Mining System (심해저 광물자원 채광시스템의 통합거동 해석)

  • Kim, Hyung-Woo;Hong, Sup;Choi, Jong-Su;Yeu, Tae-Kyeong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.311-314
    • /
    • 2006
  • This paper concerns about total dynamic analysis of integrated mining system. This system consists of vertical steel pipe, intermediate buffer station, flexible pipe and self-propelled miner. The self-propelled miner and buffer are assumed as rigid-body of 6-dof. Discrete models of vertical steel pipe and flexible pipe are adopted, which are obtained by means of lumped-parameter method. The motion of mining vessel is not considered. Instead, the motion of mining vessel is taken into account in form of various boundary conditions (e.g. forced excitation in slow motion and/or fast oscillation and so on). A terramechanics model of extremely soft cohesive soil is applied to the self-propelled miner. The hydrodynamic forces and moments are included in the dynamic models of vehicle and lifting pipe system. Hinged and fixed constraints are used to define the connections between sub-systems (vertical steel pipe, buffer, flexible pipe, miner). Equations of motion of the coupled model are derived with respect to the each local coordinates system. Four Euler parameters are used to express the orientations of the sub-systems. To solve the equations of motion of the total dynamic model, an incremental-iterative formulation is employed. Newmark-b method is used for time-domain integration. The total dynamic responses of integrated mining system are investigated.

  • PDF

Computer aided design system for robotic painting line (동장공정의 로보틱자동화를 위한 설계지원 시스템)

  • Suh, Suk-Hwan;Cho, Jung-Hoon;Kang, Dae-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.171-179
    • /
    • 1994
  • For successful implementation of robotic painting system, a structured design and analysis procedure is necessary. In designing robotic system, both functional and economical feasibility should be investigated. As the robotization is complicated task involving implemen- tation details (such as robot selection, accessory design, and spatial layout) together with operation details, the computer aided design and analysis method should be sought. However, conventional robotic design systems and off-line programming systems cannot accommodate these inquiries in a unified fashion. In this research, we develop an interactive design support system for robotization of a cycle painting line. With the developed system called SPRPL (Simulation Package for Robotic Painting Line) users can design the painting objects (via FRAME module), select robot model (ROBOT), design the part hanger (FEEDER), and arrange the workcell. After motion programming (MOTION), the design is evaluated in terms of: a) workpace analysis, b) coating thickness analysis, and c) cycle time (ANALYSIS).

  • PDF

Presentation of central motion techniques: limpness motion function and limpness sensory unit function

  • Kim, Jeong-lae;Kim, Kyu-dong
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.3
    • /
    • pp.56-61
    • /
    • 2016
  • Central motion techniques are to mention the central-motion by the limpness motion function and limpness sensory unit function on the body. Central body motion is consisted of the limpness central function by the central body system. To evaluate the signal of central body motion, we are investigated a limpness value of the central function by the central body function on the static state. The concept of limpness motion function was checked the reference of limpness motion signal and limpness sensory signal by the central motion body. For assessment on the limpness sensory variation of the maximum and average in terms of central motion from the static function, and limpness value that was a limpness value of the vision condition of the Vi-${\lambda}_{MAX-AVG}$ with $8.71{\pm}-3.2units$, that was a limpness value of the vestibular condition of the Ve-${\lambda}_{MAX-AVG}$ with $3.05{\pm}-6.52units$, that was a limpness value of the somatosensory condition of the So-${\lambda}_{MAX-AVG}$ with $2.4{\pm}1.9units$. The static sensory motion was made mention of check out at the condition of the limpness sensory unit motion for the comparable values of limpness central motion that was expressed the analysis capacity by the limpness nerve system. Limpness sensory system will be to propose of the minute motion by static central motion situation and was to imply a limpness motion data of static body sensory function.