• Title/Summary/Keyword: Motion Technique

Search Result 2,049, Processing Time 0.031 seconds

Motion-Capture-Based Animation in Mobile Embedded Systems Using Motion Capture Database Reduction Technique (데이터베이스 축소기법을 사용한 모바일 임베디드 시스템에서의 모션 캡쳐 기반 애니메이션)

  • Han, Young-Mo
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.437-444
    • /
    • 2007
  • The objective of this paper is to accommodate the existing motion-capture-based animation to small memories and low computing powers of mobile embedded systems. To use efficiently memories, we propose a paradigm in which a motion capture database is compressed on a PC and so-compressed motion capture database is decompressed little by little on mobile embedded systems and the decompressed data are eliminated right after used. As a compression method for this paradigm we propose an approach that compresses captured motion rendering parameters using a polynomial function fitting method. To enhance its performance we also propose an optimization method for the degree of the polynomial fitting function. Using so-obtained compression method we demonstrate motion-capture-based animation on commercial mobile embedded systems.

A Study on the Sway Control of a Container Crane Based on $H^{\infty}$ Gain-Scheduling Approach ($H^{\infty}$ Gain-Scheduling 기법을 이용한 컨테이너 크레인의 흔들임 제어에 관한 연구)

  • Kim, Yeong-Bok;Jeong, Yong-Gil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.7
    • /
    • pp.559-566
    • /
    • 2001
  • The sway control problem of the pendulum motion of a container hanging on the trolly, which transports containers from a container ship to trucks, is considered in the paper. In the container crane control problem, suppressing the residual swing motion of the container at the end of acceleration, deceleration or the case of that the unexpected disturbance input exists is main issue. For this problem, in general, the trolley motion control strategy is introduced and applied. In this paper, we introduce and synthesize a new type of swing motion control system in which a small auxiliary mass is installed on the spreader. The actuator reacting against the auxiliary mall applies inertial control forces to the container to reduce the swing motion in the desired manner. In this paper, we apply the $H^{\infty}$ based gain-scheduling control technique to the anti-swing motion control system design problem of the controlled plant. In this control system, the controller dynamics are adjusted in real-time according to time-varying plant parameters. And the simulation result shows that the proposed control strategy is shown to be useful for the case of time-varying system and, robust to disturbances such as winds and initial sway motion.

  • PDF

Three Clinical Cases on Acute Lumbar Sprain Patients with Limited Range of Motion by Chuna Treatment (Saban-Method Technique) and Oriental Medical Treatments (관절 가동범위 제한을 동반한 급성 요추부 염좌 환자에 요부사반법(腰部斜搬法)과 한방치료를 병행한 치험 3례)

  • Lee, Kyung-Moo;Ahn, Hee-Bin;Lim, Sang-Hoon;Kim, Soon-Joong;Jeong, Su-Hyeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.4
    • /
    • pp.189-202
    • /
    • 2009
  • Objectives : This study was performed to evaluate the effects of Chuna treatment (Saban-method technique) on acute lumbar sprain patients with limited range of motion(LOM). Methods : Three patients suffered from acute lumbar sprain with LOM, were treated with Chuna therapy(Saban-method technique), acupuncture, herbal medicine, physical therapy and measured by VAS(Visual Analogue Scale) and ODI(Oswestry Disability Index). Results : After Chuna treatment and oriental medical treatments, we found out a recovery from three patients suffering from acute low back pain with LOM. Conclusions : Through this study, we suggest that Chuna treatment(Saban-method technique) and oriental medical treatments was effective to cure acute lumbar sprain patient with LOM.

The Pilot Study on the Immediate Effects of Graston Technique for Lower Extremity Range of Motion, Muscle Strength, Walking Ability in Hemiplegic Patients (그라스톤을 이용한 연부조직가동술이 편마비 환자의 하지 관절 가동범위, 근력, 보행 능력에 미치는 즉각적인 영향에 관한 예비 연구)

  • Choi, Yul-jung;Sim, Hyun-po;Lee, Jun-yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.25 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Background: The purpose of this study was to investigate the effects of Graston technique for lower extremity range of motion (ROM), muscle strength, walking ability in hemiplegia patients. Methods: Twelve subjects participated in this study. The ROM of the knee extension was measured by 90-90 straight leg raise test, the hamstring and quadriceps muscle strength was collected by utilizing a handheld dynamometer. In addition walking speed was evaluated by 10 meter walking test. The group was applied intervention using a Graston instrument for one minute. After intervention, immediate effect was assessed. The significant level was set at ${\alpha}=.05$. Results: The ROM of the knee extension, quadriceps muscle strength and walking speed were significantly increased. Hamstring muscle strength was significantly reduced. Conclusion: The results of this study suggest that Graston instrument technique has the effect of instantaneously flexibility the muscles, and the muscle applied with the technique has weakened, while the muscle of the opposite side has increased the muscle strength. In addition, the muscle flexibility and the walking speed have increased.

Computer Graphic Animation based on Forward Dynamic Simulation (Forward Dynamic 시뮬래이션을 이용한 컴퓨터 그래픽 애니매이션)

  • Park, Jihun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.1
    • /
    • pp.48-60
    • /
    • 1996
  • This paper present a new technique for doing realistic computer animation. The method is based on forward dynamic simulation and nonlinear problem solving (parameter optimization) technique. Objects are modelled physically and simulated faithfully while satisfying kinematic and geometric constraints. This forward dynamic simulation gives us very realistic motions especially for non-voluntary motions. Then we extend simulation technique to do animation using parameter optimization. The basic idea is to add motion control over the entire animation. The motion control is finding optimal solutions while satisfying user's animation goals. We provide two different animation technique; one is for rigid body without joint actuators and the other is for rigid body with linear joint actuators. To achieve motion control, we convert single simulation to single nonliner function evaluation while either setting initial conditions as variables for the function or allocating control variables in terms of time. This method is presented with two animation examples: dice-magic and human stand-up.

  • PDF

Video Production Method using Match Moving Technique (매치무빙 기법을 활용한 모션그래픽 영상제작에 관한 연구)

  • Lee, Junsang;Park, Junhong;Lee, Imgeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.755-762
    • /
    • 2016
  • Motion graphic is the recently emerged technique which extends the ways of expression in video industry. Currently, it is worldwide trends that the image design gets more attention in the field of movie, advertisement, exhibition, web, mobile, games and new media, etc. With the development of computer's new technologies, VFX methods for the visual content is dynamically changed. Such production methods combine the real scenary and CG(Computer Graphic) to compose realistic scenes, which cannot be pictured in the ways of ordinary filming. This methods overcome the difference between the real and virtual world, maximize the expressive ways in graphics and real space. Match moving is technique of accurate matching between real and virtual camera to provide realistic scene. In this paper we propose the novel technique for motion graphic image production. In this framework we utilize the match moving methods to get the movements of the real camera into 3D layer data.

Analysis of Performance for Entropy-Based ISAR Autofocus Technique (엔트로피 기반의 ISAR 자동 초점 기법에 대한 성능 분석)

  • Bae, Jun-Woo;Kim, Kyung-Tae;Lee, Jin-Ho;Im, Jeong-Heom
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1249-1258
    • /
    • 2006
  • Two-dimensional(2-D) radar images, namely, ISAR images from a maneuvering target include unwanted phase errors due to the target's motion. These phase errors make ISAR images to be blurred. The ISAR autofocus technique is required in order to remove these unwanted phase errors. Unless those unwanted phase errors produced by the target's motion are removed prior to target identification, we cannot expect a reliable target identification performance. In this paper, we use the entropy-based ISAR autofocus technique which consists of two steps: range alignment and phase adjustment. We analyze a relationship between the number of sampling point and a image quality in a range alignment algorithm and also analyze a technique for reducing computation time of the SSA(Stage-by-Stage Approachng) algorithm in a phase adjustment.

Distributed Coding Scheme for Multi-view Video through Efficient Side Information Generation

  • Yoo, Jihwan;Ko, Min Soo;Kwon, Soon Chul;Seo, Young-Ho;Kim, Dong-Wook;Yoo, Jisang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1762-1773
    • /
    • 2014
  • In this paper, a distributed image coding scheme for multi-view video through an efficient generation of side information is proposed. A distributed video coding technique corrects the errors in the side information, which is generated with the original image, by using the channel coding technique at the decoder. Therefore, the more correct the generated side information is, the better the performance of distributed video coding. The proposed technique is to apply the distributed video coding schemes to the image coding for multi-view video. It generates side information by selectively and efficiently using both 3-dimensional warping based on the depth map with spatially adjacent frames and motion-compensated temporal interpolation with temporally adjacent frames. In this scheme the difference between the adjacent frames, the sizes of the motion vectors for the adjacent blocks, and the edge information are used as the selection criteria. From the experiments, it was observed that the quality of the side information generated by the proposed technique was improved by the average peak signal-to-noise ratio of 0.97dB than the one by motion-compensated temporal interpolation or 3-dimensional warping. The result from analyzing the rate-distortion curves revealed that the proposed scheme could reduce the bit-rate by 8.01% on average at the same peak signal-to-noise ratio value, compared to previous work.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF