• 제목/요약/키워드: Motion Technique

Search Result 2,049, Processing Time 0.031 seconds

Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 슬개건을 이용한 전방 십자 인대 재건술의 수술 후 합병증)

  • Zhu, Fang Zhen;Yoo, Moon-Jib;Kim, Myung-Ho;Park, Hee-Gon;Bahng, Seung-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: Evaluation and analysis of the incidence of postoperative complications after arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. Materials and Methods: We reviewed 172 cases of arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft in anterior cruciate ligament tear without meniscal injury. We performed Lysholm knee score and KT-2000 testing, simple radiograph, physical examination as evaluation factor. Also, around knee pain, swelling, limitation of motion, patellofemoral crepitation, paresthesia and pain on kneeling were evaluated. Results: The average follow up period was 49.8 months. In 172 patients, 148 males and 26 femlaes were evaluated. The average age was 34.4 years. The Lysholm knee score improved from 51.9 points preoperatively to 90.8 points at final follow up. Clinical outcome was excellent in 83%, good in 11%, fair in 4% and poor in 2%. There were many cases of complications, 24 cases (14%) of around knee pain, 12 cases (7%) of swelling, 45 cases (26.2%) of patellofemoral crepitation, 52 cases (30%) of donor site paresthesia, 65 cases (38%) of pain on kneeling, 10 cases (5.8%) of limitation of motion at extension, 13 cases (8%) of limitation of motion at flexion and 2cases (1.2%) of patellar fracture. Conclusion: Although arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone had good clinical results, many complications were noted. Some factors in surgical technique were suspected to be related to the complications and long term follow up will be necessary to further evaluated.

  • PDF

The Proprioceptive Function of Rotator Cuff Tear Patients: Preliminary Report of Pre-operative Function (회전근개 파열 환자의 고유 수용성 감각 기능: 수술전 기능의 예비 보고)

  • Lee, Hyunil;Heo, Jaewon;Yoo, Jae Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • Purpose: Proprioceptive function has been known to be important to shoulder stability. However, the function in rotator cuff tear patients is rarely investigated. The purpose of current study is to report the proprioceptive function in rotator cuff tear patients and to analyze the proprioceptive function regarding the tear size and the presence of subscapularis tear. Materials and Methods: Between 2011 and 2012, total 76 patients (male 28 and female 48) were recruited and average age was 61.7 years old (range, 38~76). Preoperatively, joint position senses in internal and external rotation were measured for proprioceptive function testing by method of active re-positioning technique. The absolute difference from set point was measured. Proprioceptive function was further analyzed according to tear size of rotator cuff, the presence of subscapularis tear, visual analogue scale of pain, shoulder functional score (American society of elbow and shoulder score), and ranges of motion in shoulder. Results: The absolute difference for external rotation was $4.9^{\circ}{\pm}2.9^{\circ}$, in normal joint and $4.9^{\circ}{\pm}3.0^{\circ}$for involved joint in rotator cuff tear patients. This difference was not significant statistically (p=0.87). The absolute difference for internal rotation was $4.0^{\circ}{\pm}2.7^{\circ}$in normal joint whereas $4.8^{\circ}{\pm}3.7^{\circ}$ for involved joint showing statistically significant difference (p=0.043). There was some trend that the proprioceptive function of internal rotation was more impaired in the bigger tear size group (more than medium tear) compared to the smaller tear size group (partial thickness and small tear, 5.0 vs. 4.0, p=0.061). The impairment of internal rotation proprioception was also accentuated in patients with subscapularis tear (4.8 vs. 4.0, p=0.065). The proprioceptive function of internal rotation was decreased when the pain visual analogue scale was increased (5.2 vs. 4.0 p=0.04), shoulder functional score was decreased (6.1 vs. 4.2, p=0.005), or range of motion in shoulder joint was restricted (5.3 vs. 3.7, p=0.041). Conclusion: The deficit of proprioceptive function was observed in rotator cuff tear patients. Proprioception for internal rotation was impaired in patients with the bigger tear size and subscapularis tear. Pain, shoulder function score, and range of motion were also shown to be related with the deficit in proprioceptive function.

  • PDF

Radiofrequency thermal Shrinkage for Elongated Anterior Cruciate Ligament after Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술 이후 이완된 전방십자인대에 시행한 고주파 에너지 열 수축)

  • Kim, Yeung-Jin;Chun, Churl-Hong;Kim, Tae-Kyun;Yang, Hwan-Deok;Kim, Hyoung-Joon;Kim, Young-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: To evaluate the clinical results of the patients who underwent radiofrequency thermal shrinkage (RFTS) for treatment of anterior cruciate ligament (ACL) laxity after ACL reconstruction. Material and Methods: From October 1999 to March 2006, we performed 133 cases of ACL reconstruction. Among them we experienced 16 patients who had the laxity of reconstructed ACL in second look arthroscopy. Mean follow-up was 20.4 months. Mean age was 33.5 years. 12 cases were male and 4 cases were female. The elongated ACL were treated by bipolar radiofrequency energy with an output of grade II. Subjective and objective parameters were utilized in analyses, such as: the mean range of motion, Lysholm knee score, Tegner activity score, Lachman test, IKDC score. Wilcoxon signed-rank test was used to perform the data analysis. P<0.05 was considered to be statistically significant. Results: Postoperative mean Lysholm knee score (preop: $82.2{\pm}5.2(77{\sim}85))$ (P=0.04), postop: $85.2{\pm}4.8$(82-90)) and anterior displacement by the Telos stress test (preop: $5.4{\pm}4.6(3{\sim}10)mm$, postop: $2.1{\pm}1.9(0{\sim}4)mm)$ (P=0.02), Lachman's test, and IKDC scores (P=0.04) demonstrated significant differences statistically compared to the preoperative. There were no statistical differences in mean range of motion, Tegner activity scale. Conclusions: Arthroscopic shrinkage for the ACL laxity after ACL reconstruction with radiofrequency device showed good clinical results and was applicable operative technique.

  • PDF

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

Functional Result of Limb Salvage Surgery with Tumor Prosthesis for Osteosarcoma of Proximal Tibia (근위 경골 골육종의 종양대치물을 이용한 사지 구제술 후의 기능 평가)

  • Bahk, Won-Jong;Sohn, Jong-Min;Chung, Yang-Guk;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.139-143
    • /
    • 2001
  • Purpose : Limb salvage for osteosarcoma of proximal tibia is challenging problem due to difficulties in mobilizing or retracting the main neurovascular structure, inadequate soft tissue coverage, and unsolved problem of patellar tendon reattachment to endoprosthesis. The authors analyzed the functional result of limb salvage using tumor prosthesis with medial gastrocnemius rotation plasty for osteosarcama of the proximal tibia. Materials and Methods : Eleven patients with histologically proven osteosarcoma of the proximal tibia, treated with adjuvant and neoadjuvant chemotherapy and limb salvage operation with tumor prosthesis between January 1992 and December 1998 at our Medical Center, were selected. There were 6 male and 5 female. Age ranged from 15 years to 23.7 years with an average of 23.7 years. Follow-up period ranged from 1 year to 4.5 years with an average of 2.5 years. The final functional result was evaluated using the method by ISOLS, 1993. The factors include pain, functional activities, emotional acceptance, use of external supports, walking ability and gait. Each of the factors has been scored from 0 to 5 depending on the appropriate description or data. The rating score is determined by dividing the individual factor scores into the total score and indicates percentage of normal function. Results : The overall functional result ranged from 53,3% to 86.7% with an average of 68.3% of normal function. In details, the averages were 82.5% for pain, 62.5% for functional activities, 67.5% for emotional acceptance, 77.5% for use of external supports, 62.5% for walking ability, and 57.5% for gait. The average range of motion of the knee joint was $5^{\circ}$ extension and $85^{\circ}$ flexion. Five patients have extension lag ranged from $5^{\circ}$ to $15^{\circ}$ with an average of $10^{\circ}$. Two patients suffered postoperative infection. One was treated with antibiotics injection only, but the other needed removal of the prosthesis and knee fusion. Both of them showed unsatisfactory result. C o n c l u s i o n : The overall functional result after limb salvage using tumor prosthesis with medial gastrocnemius rotational flap for osteosarcoma of the proximal tibia was relatively satisfactory in case of no postoperative infection. The patients were less satisfactory in functional activities, emotional acceptance and gait than pain, use of external supports due to limitation of motion and extension lag. More aggressive postoperative physical therapy and protection with brace for 6~9 months as well as surgical technique is mandatory for more satisfactory result.

  • PDF

Arthroscopic Double-Bundle Reconstruction of Anterior Cruciate Ligament (관절경을 이용한 전방 십자 인대의 이중 다발 재건술)

  • Jung, Young-Bok;Park, Se-Jin;Jung, Ho-Joong;Yoo, Jae-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Purposes: The purpose of this study was to report surgical technique of double bundle anterior cruciate ligament(ACL) reconstruction and to compare the short-term clinical results between arthroscopic single-bundle and double-bundle ACL reconstruction. Materials and Methods: From May 2005 to May 2006, ninety-eight patients were underwent ACL reconstruction. We designed prospective study with sixty-one patients who were revealed isolated ACL injury. We serially checked clinical and radiologic data preoperatively and postoperatively. We compared single-bundle with double-bundle ACL reconstruction patients with preoperative datas and postoperatively 1-year data. There were 30 single bundle reconstruction and 31 double bundle reconstruction. Stability was assessed objectively by anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer. The clinical results were assessed by IKDC(International Knee Documentation Committee) and OAK(Orthopadische Arbeitsgruppe Knie) scores. Also, we evaluated postoperative thigh circumference and range of motion. All of operations were done by only one surgeon. Results: At single-bundle reconstruction group, preoperative AP instability which was checked by $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer was $7.9{\pm}3.3$ and $7.4{\pm}2.0$, respectively. At double-bundle reconstruction group, it was $8.3{\pm}3.5$ and $7.9{\pm}3.2$, respectively. Residual AP laxity checked at 1 year after operation was $1.9{\pm}1.2$ and $2.2{\pm}1.6$ in single-bundle reconstruction group, and $1.1{\pm}0.9$ and $1.0{\pm}1.0$ in double-bundle reconstruction group. So, double-bundle reconstruction had better results in both anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer, and there were significant differences in statistics. But, clinical results such as IKDC(International Knee Documentation Committee) scores, OAK(Orthopadische Arbeitsgruppe Knie) scores, thigh circumference and range of motion had no significant difference between two groups. Conclusions: On the basis of stability, the side-to-side anterior laxity of double-bundle ACL reconstruction was significantly better than that of single-bundle reconstruction, although there were no significant differences in the other clinical measures among them.

  • PDF

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

Comparison of Wind Vectors Derived from GK2A with Aeolus/ALADIN (위성기반 GK2A의 대기운동벡터와 Aeolus/ALADIN 바람 비교)

  • Shin, Hyemin;Ahn, Myoung-Hwan;KIM, Jisoo;Lee, Sihye;Lee, Byung-Il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1631-1645
    • /
    • 2021
  • This research aims to provide the characteristics of the world's first active lidar sensor Atmospheric Laser Doppler Instrument (ALADIN) wind data and Geostationary Korea Multi Purpose Satellite 2A (GK2A) Atmospheric Motion Vector (AMV) data by comparing two wind data. As a result of comparing the data from September 2019 to August 1, 2020, The total number of collocated data for the AMV (using IR channel) and Mie channel ALADIN data is 177,681 which gives the Root Mean Square Error (RMSE) of 3.73 m/s and the correlation coefficient is 0.98. For a more detailed analysis, Comparison result considering altitude and latitude, the Normalized Root Mean Squared Error (NRMSE) is 0.2-0.3 at most latitude bands. However, the upper and middle layers in the lower latitudes and the lower layer in the southern hemispheric are larger than 0.4 at specific latitudes. These results are the same for the water vapor channel and the visible channel regardless of the season, and the channel-specific and seasonal characteristics do not appear prominently. Furthermore, as a result of analyzing the distribution of clouds in the latitude band with a large difference between the two wind data, Cirrus or cumulus clouds, which can lower the accuracy of height assignment of AMV, are distributed more than at other latitude bands. Accordingly, it is suggested that ALADIN wind data in the southern hemisphere and low latitude band, where the error of the AMV is large, can have a positive effect on the numerical forecast model.