• Title/Summary/Keyword: Motion Synchronization

Search Result 91, Processing Time 0.023 seconds

LED Driver Solution for Backlighting large TFT-LCD Panels with Adaptive Power Control & Video Synchronization

  • Dhayagude, Tushar;Dilip, S;Santo, Hendrik;Vi, Kien;Chen, Sean;Kim, Min-Jong;Schindler, Matt;Ghoman, Ran
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1487-1490
    • /
    • 2008
  • mSilica developed a scalable integrated circuit solution for driving multiple arrays of LEDs to backlight TFT-LCD panels. The drivers incorporate adaptive power control of the DC-DC power supply powering the LEDs to improve the efficiency while synchronizing PWM dimming with video timing signals VSYNC and HSYNC to reduce motion blur.

  • PDF

Device Server Based Synchronization of a Simulator Reflecting Motion Base Characteristics (디바이스 서버를 이용한 모션 베이스 특성에 따른 시각적 동기화)

  • 박형근;김종국;정의정;송재복;고희동
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.47-52
    • /
    • 2002
  • 가상공간에서 탑승자에게 운동감을 제공하기 위해서 수많은 형태의 모션 시뮬레이터가 개발되어 왔다. 하지만 이러한 형태의 시뮬레이터들은 그 고유한 형태에 의해 정해진 동역학과 워시아웃 알고리즘을 거쳐야만 정밀한 시뮬레이터가 될 수 있다. 본 논문은 기존의 좁은 시야공간에서의 시뮬레이터가 아닌 넓은 시야를 제시하고, 모션 베이스와 독립적으로 운영되는 영상 제시기를 이용하여 탑승자에게 운동감을 제공하는 분리형 시뮬레이터를 대상으로 하여 영상과 모션을 동기화시켜서 제시하는 방법에 대해 논의하고자 한다.

  • PDF

New Decision Rules for UWB Synchronization (UWB 동기화를 위한 새로운 결정 법칙들)

  • Chong, Da-Hae;Lee, Young-Yoon;Ahn, Sang-Ho;Lee, Eui-Hyoung;Yoo, Seung-Hwan;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2C
    • /
    • pp.192-199
    • /
    • 2008
  • In ultra-wideband (UWB) systems, conventionally, the synchronization is to align time phases of a locally generated template and any of multipath components to within an allowable range. However, the synchronization with a low-power multipath component could incur significant performance degradation in receiver operation (e.g., detection) after the synchronization. On the other hand, the synchronization with a high-power multipath component can improve the performance in receiver operation after the synchronization. Generally, the first one among multipath components has the largest power. Thus, the synchronization with the first path component can make better performance than that with low-power component in receiver operation after the synchronization, Based on which, we first propose an optimal decision rule based on a maximum likelihood (ML) approach, and then, develope a simpler suboptimal decision rule for selecting the first path component. Simulation results show that the system has good demodulation performance, which uses new synchronization definition and the proposed decision rules have better performance than that of the conventional decision rule in UWB multipath channels. Between macroblocks in the previous and the current frame. On video samples with high motion and scene change cases, experimental results show that (1) the proposed algorithm adapts the encoded bitstream to limited channel capacity, while existing algorithms abruptly excess the limit bit rate; (2) the proposed algorithm improves picture quality with $0.4{\sim}0.9$dB in average.

Development of a Cardiac Catheter Remote Control Robot Platform for Radiofrequency Ablation Intervention (고주파 절제술을 위한 심장전극도자 원격 제어 로봇 플랫폼의 개발)

  • Park, Jun-Woo;Song, Seung-Joon;Lee, Jung-Chan;Choi, Hyuk;Lee, Jung-Joo;Choi, Jae-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1417-1426
    • /
    • 2011
  • Radiofrequency ablation through cardiac catheterization is one of minimally invasive intervention procedures used in drug resistant arrhythmia treatment. To facilitate more accurate and precise catheter navigation, systems for robotic cardiac catheter navigation have been developed and commercialized. The authors have been developing a novel robotic catheter navigation system. The system is a network-based master-slave configuration 3-DOF (Degree-Of-Freedom) robotic manipulator for operation with conventional cardiac ablation catheter. The catheter manipulation motion is composed of the translation (forward/backward) and the roll movements of the catheter and knob rotation for the catheter tip articulation. The master manipulator comprises an operator handle compartment for the knob and the roll movement input, and a base platform for the translation movement input. The slave manipulator implements a robotic catheter platform in which conventional cardiac catheter is mounted and the 3-DOF motions of the catheter are controlled. The system software that runs on a realtime OS based PC, implements the master-slave motion synchronization control in the robot system. The master-slave motion synchronization performance tested with step, sinusoidal and arbitrarily varying motion commands showed satisfactory results with acceptable level of steady state error. The developed system will be further improved through evaluation of safety and performance in in vitro and in vivo tests.

A Study on Sensor-Based Upper Full-Body Motion Tracking on HoloLens

  • Park, Sung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2021
  • In this paper, we propose a method for the motion recognition method required in the industrial field in mixed reality. In industrial sites, movements (grasping, lifting, and carrying) are required throughout the upper full-body, from trunk movements to arm movements. In this paper, we use a method composed of sensors and wearable devices that are not vision-based such as Kinect without using heavy motion capture equipment. We used two IMU sensors for the trunk and shoulder movement, and used Myo arm band for the arm movements. Real-time data coming from a total of 4 are fused to enable motion recognition for the entire upper body area. As an experimental method, a sensor was attached to the actual clothes, and objects were manipulated through synchronization. As a result, the method using the synchronization method has no errors in large and small operations. Finally, through the performance evaluation, the average result was 50 frames for single-handed operation on the HoloLens and 60 frames for both-handed operation.

Detection of Neuronal Activity by Motion Encoding Gradients: A Snail Ganglia Study

  • Park, Tae-S.;Park, Ji-Ho;Cho, Min-H.;Lee, Soo-Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.24-28
    • /
    • 2007
  • Presuming that firing neurons have motions inside the MRI magnet due to the interaction between the neuronal magnetic field and the main magnetic field, we applied motion encoding gradients to dissected snail ganglia to observe faster responding MRI signal than the BOLD signal. To activate the snail ganglia in synchronization with the MRI pulse sequence, we used electrical stimulation with the frequency of 30 Hz and the pulse width of 2s. To observe the fast responding signal, we used the volume selected MRI sequence. The magnetic resonance signal intensity, measured with 8 ms long motion encoding gradient with a 20mT/m gradient strength, decreased about $3.46{\pm}1.48%$ when the ganglia were activated by the electrical stimulation.

A study on the Performance Improvement in Trapping Signal Processing Method of RLG (RLG Trapping 신호처리 기법의 성능개선에 관한 연구)

  • Yoo, Ki-Jeong;Kim, Cheon-Joong;Shim, Kyu-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.10
    • /
    • pp.1003-1010
    • /
    • 2008
  • In this paper, we propose the new method to decrease the navigation error by measurement time synchronization error in RLG Trapping signal processing. There are two methods to eliminate the dither motion in RLG. One is the stripping signal processing method. Another is the trapping signal processing method. This two methods have various error sources in measurement output. We perform the error modelling and analysis for the measurement time synchronization error between angular rate from RLG and acceleration from accelerometer in the trapping signal processing method. And we verify the navigation performance through simulation and experiment. Results of simulation and experiment show that the proposed method is very effective in decreasing the navigation error.

The Evaluation of Performance of 2-Axis Polishing Robot Attached to Machining Center (머시닝센터 장착형 2축 연마 로봇의 성능평가)

  • 박준혁
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.411-416
    • /
    • 2000
  • Cutting process has been automated by progress of CNC and CAD/CAM, but polishing process has been depended on only experiential knowledge of expert. To automate the polishing process, a polishing robot with w degrees of freedom which is attached to a machining center with 3 degrees of freedom has been developed. This automatic polishing robot is able to keep the polishing tool normal on the curved surface of die to improve a performance of polishing. Polishing task for a curved surface die demands repetitive operation and high precision, but conventional control algorithm can not cope with the problem of disturbance such as a change of load. In this research, a new sliding mode control algorithm is applied to the robot. The signal compression method is used to identify polishing robot system. to obtain an effect of 5 degrees of freedom motion, a synchronization between the machining center and polishing robot is accomplished by using M code of machining center. And also a trajectory for polishing the curved surface die by 5 degrees of freedom motion, a synchronization between the machining center and polishing robot is accomplished by using M code of machining center. And also a trajectory for polishing the curved surface die by 5 axes machining center is divided into data of two types for 3 axes machining center and 2 axes polishing robot. To evaluate polishing performance of the robot. various experiments are carried out.

  • PDF

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.

Nonlinear Adaptive Control for Position Synchronization of a Gantry-Moving-Type Linear Motor (겐트리형 리니어 모터의 동기화를 위한 비선형 적응제어)

  • Han, Sang-Oh;Kim, In-Keun;Huh, Kun-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1925-1930
    • /
    • 2010
  • For high-speed/high-accuracy position control of a gantry-moving-type linear motor, we propose a nonlinear adaptive controller including a synchronization algorithm. Linear motors are easily affected by force ripple, friction, and parameter variations because there is no mechanical transmission to reduce the effects of model uncertainties and external disturbances. Synchronization error is also caused by skew motion, model uncertainties, and force disturbance on each axis. Nonlinear effects such as friction and ripple force are estimated and compensated for. The synchronization algorithm is used to reduce the synchronous error of the two side pillars. The performance of the controller is evaluated via computer simulations.