• Title/Summary/Keyword: Motion Comparison

Search Result 1,227, Processing Time 0.03 seconds

The Effect of Action on the Balance and the Trunk Control Ability in the Sit Position of Chronic Stroke Patients (동작관찰훈련이 만성 뇌졸중 환자의 앉은 자세에서 균형과 몸통조절능력에 미치는 영향)

  • Hwang, Junhyun;Lee, Yangjin;Joo, Mincheol;Kim, Seongryeol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.1-9
    • /
    • 2019
  • Purpose : To find out how action observation training for chronic stroke patients affects their balance and body control abilities in the posture seated in the rehabilitation of stroke. Methods : This study was conducted on 30 subjects who were diagnosed with stroke. The group conducted motion observation training through video clips, while the control group only conducted physical training, and the general physical therapy was performed equally by both counties. The static balance was measured using Biorescue and the dynamic balance was measured using Modified Functional Reach Test (MFRT), Postural Assessment Scale for Stroke, and Trunk Impairment Scale. Results : Static balance showed statistically significant difference in foot pressure (p<.05) as a result of comparison between pre and post exercise training. Dynamic balance was statistically significant (p>.05) as a result of comparing pre and post differences using modified functional reach test. The trunk control ability was statistically significant (p>.001). Comparison between the results of before and after motion observation training showed a statistically significant difference. Conclusion: This study confirmed that exercise training in sitting position was effective for static, dynamic balance ability and trunk control ability of hemiplegic patients due to stroke. These results suggest that the use of motion monitoring in stroke patients may have a positive impact on the diversity and function of rehabilitation.

Effect of the Proprioceptive Neuromuscular Facilitation Pattern Exercise and Scrambler Treatment on Pain, Range of Motion, and Shoulder Dysfunction in Breast Cancer Patients (고유수용성신경근촉진법 패턴 운동과 스크램블러 치료가 유방암 환자의 통증과 가동범위 및 어깨기능장애에 미치는 영향)

  • Jae-Cheol Park;Han-Kyu Park;Dong-Kyu Lee
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.53-61
    • /
    • 2023
  • Purpose: The study aims to examine the effects of the proprioceptive neuromuscular facilitation pattern exercise and scrambler therapy on pain, range of motion (ROM), and shoulder dysfunction in breast cancer patients. Methods: In total, 30 breast cancer patients were recruited and randomized to group I (n = 10), group II (n = 10), and group III (n = 10). Pain was measured using a visual analogue scale, ROM was measured using a goniometer, and shoulder dysfunction was measured using a shoulder pain and disability index. Group I practiced the proprioceptive neuromuscular facilitation pattern exercise and underwent scrambler therapy, group II underwent scrambler therapy only, and group III practiced the proprioceptive neuromuscular facilitation pattern exercise only. Results: A within-groups comparison showed that all groups demonstrated significant differences in pain, ROM, and shoulder dysfunction after the experiment (p<0.05). Further, according to a comparison of the three groups, group I showed a more significant difference in effectiveness than groups II and III in terms of pain, ROM, and shoulder dysfunction before and after the experiment (p<0.05). Conclusion: This study showed that the proprioceptive neuromuscular facilitation pattern exercise and scrambler therapy are effective in treating pain, ROM issues, and shoulder dysfunction in breast cancer patients.

A Novel System with EMG-controlled FES Enhanced Gait Function and Energy Expenditure for Older Adults

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung cheol Shin;Hwang-Jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.152-162
    • /
    • 2024
  • Objective: This study was conducted to analyze the effect of wearable Electromyography-controlled functional electrical stimulation (EMG-controlled FES) System on Gait Function and cardiopulmonary metabolic efficiency during walking in older adults. Design: Cross-section study Methods: Total 22 older adult participants suitable to selection criteria of this study participated in this study. The EMG-controlled FES System, which functions as a wearable physical activity assist FES system was used. All participations performed randomly assigned two conditions (Non-FES assist [NFA], FES assist [FA]) of walking. In all conditions, spatio-temporal parameters and kinematics and kinetics parameters during walking was collected via 3D motion capture system and 6 minutes walking test (6MWT) and metabolic cost during walking and stairs climbing was collected via a portable metabolic device (COSMED K5, COSMED Srl, Roma, Italy). Results: In Spatio-temporal parameters aspects, The EMG-controlled FES system significantly improved gait functions measurements of older adults with sarcopenia at walking in comparison to the NFA condition (P<0.05). Hip, knee and ankle joint range of motion increased at walking in FA condition compared to the NFA condition (P<0.05). In the FA condition, moment and ground reaction force was changed like normal gait during walking of older adults in comparison to the NFA condition (P<0.05). The EMG-controlled FES system significantly reduced net cardiopulmonary metabolic energy cost, net energy expenditure measurement at stairs climbing (P<0.05). Conclusions: This study demonstrated that EMG-controlled FES is a potentially useful gait-assist system for improving gait function by making joint range of motion and moment properly.

A comprehensive analysis on the discretization method of the equation of motion in piezoelectrically actuated microbeams

  • Zamanian, M.;Rezaei, H.;Hadilu, M.;Hosseini, S.A.A.
    • Smart Structures and Systems
    • /
    • v.16 no.5
    • /
    • pp.891-918
    • /
    • 2015
  • In many of microdevices a part of a microbeam is covered by a piezoelectric layer. Depend on the application a DC or AC voltage is applied between upper and lower side of the piezoelectric layer. A common method in many of previous works for evaluating the response of these structures is discretizing by Galerkin method. In these works often single mode shape of a uniform microbeam i.e. the microbeam without piezoelectric layer has been used as comparison function, and so the convergence of the solution has not been verified. In this paper the Galerkin method is used for discretization, and a comprehensive analysis on the convergence of solution of equation that is discretized using this comparison function is studied for both clamped-clamped and clamped-free microbeams. The static and dynamic solution resulted from Galerkin method is compared to the modal expansion solution. In addition the static solution is compared to an exact solution. It is denoted that the required numbers of uniform microbeam mode shapes for convergence of static solution due to DC voltage depends on the position and thickness of deposited piezoelectric layer. It is shown that when the clamped-clamped microbeam is coated symmetrically by piezoelectric layer, then the convergence for static solution may be obtained using only first mode. This result is valid for clamped-free case when it is covered by piezoelectric layer from left clamped side to the right. It is shown that when voltage is AC then the number of required uniform microbeam shape mode for convergence is much more than the number of required mode in modal expansion due to the dynamic effect of piezoelectric layer. This difference increases by increasing the piezoelectric thickness, the closeness of the excitation frequency to natural frequency and decreasing the damping coefficient. This condition is often indefeasible in microresonator system. It is concluded that discreitizing the equation of motion using one mode shape of uniform microbeam as comparison function in many of previous works causes considerable errors.

Difference of Early Muscle Strengthening Exercises on Pain, Function and Sleep Quality for Rotator Cuff Partial Tear Patients (회전근개 부분 파열환자의 조기 근력강화운동이 어깨관절의 통증, 기능 및 수면의 차이)

  • Bang, Hyoji;Lee, Hyojeong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.3
    • /
    • pp.1-15
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate the difference of early muscle strengthening exercise(starting at 1 week) on pain, function and sleep quality for rotator cuff partial tear patients. Method : Experimental group 15 people, control group 15 people, was a total of 30 people. Group-specific arbitration method, was applied to early muscle strengthening exercise (experimental group) and general movement treatment(Starting at 6 week) (control group). Both groups were subjected to 40 minutes of basic physical therapy interventions four times a week over an six-week intervention period. In this study, Pain, function and sleep quality measured by VAS, PPT and ROM, CMS, SST and PSQI. Result : 1. The VAS and PPT in the experimental group and control group before and after treatment were significant difference(p<.01). Comparison between the two groups in the change in motion before and after treatment also showed a statistically significant(p<.01). 2. Comparison functional Assessment of the shoulder ROM, CMS and SST in the experimental group and control group before and after treatment were significant difference(p<.01). ROM was not significant differences between the groups but CMS and SST were significant differences between the groups. 3. PSQI in the experimental group and control group before and after treatment were significant difference(p<.01). Comparison between the two groups in the change in motion before and after treatment also showed a statistically significant(p<.01). Conclusion : Therefore, early muscle strengthening exercise is useful to improve the shoulder function and pain for rotator cuff tear patients.

Is Adjacent Segment Disease More Frequent in Proximal Levels in Comparison with Distal Levels? Based on Radiological Data of at Least 2 Years Follow Up with More than 2 Level Thoracolumbar Fusions

  • Kim, Jung-Ho;Ryu, Dal-Sung;Yoon, Seung-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.603-609
    • /
    • 2019
  • Objective : The purpose of this retrospective study was to determine which of the proximal adjacent segment disease (ASD) and distal ASD was more prevalent and what parameters is more related to ASD in proximal levels and distal levels after more than 2 levels fusions. Methods : The medical records were reviewed retrospectively for 856 cases. A total of 66 cases of ASD were enrolled. On preop magnetic resonance imaging, disc degeneration was measured at the upper and lower parts of surgically treated levels and confirmed by the commonly used Pfirrmann grade. Segmental flexibility in sagittal plane was embodied in segment range of motion (ROM) obtained through flexion and extension X-ray before surgery. Coronal angle was recorded as methods Cobb's angle including fusion levels preoperatively. For the comparison of categorical variables between two independent groups, the chi-square test and Fisher exact test were performed. Results : Proximal ASD and distal ASD were 37/856 (4.32%) and 29/856 (3.39%), respectively. The incidence of proximal ASD was relatively high but insignificant differences. In comparison between ASD group and non ASD group, proximal Pfirmman was higher in proximal ASD and distal Pfirmman was higher in distal ASD group (p=0.005, p<0.008, respectively). However, in the ROM, proximal ROM was higher in proximal ASD, but distal ROM was not different between the two groups (p<0.0001, p=0.995, respectively). Coronal angle was not quite different in both groups (p=0.846). Conclusion : In spite of higher frequency in ASD in proximal level in spinal fusion, it is not clear that incidence of ASD in proximal level is not higher than that of distal ASD group in more than 2 level thoracolumbar fusions. Not only Pfirrmann grade but also proximal segmental ROM is risk factor for predicting the occurrence of ASD in patients more than 2 level of thoracolumbar spine fusion operation excluding L5S1.

Efficient SAD Processor for Motion Estimation of H.264 (H.264 움직임 추정을 위한 효율적인 SAD 프로세서)

  • Jang, Young-Beom;Oh, Se-Man;Kim, Bee-Chul;Yoo, Hyeon-Joong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.2 s.314
    • /
    • pp.74-81
    • /
    • 2007
  • In this paper, an efficient SAD(Sum of Absolute Differences) processor structure for motion estimation of H.264 is proposed. SAD processors are commonly used both in full search methods for motion estimation and in fast search methods for motion estimation. Proposed structure consists of SAD calculator block, combinator block, and minimum value calculator block. Especially, proposed structure is simplified by using Distributed Arithmetic for addition operation. The Verilog-HDL(Hard Description Language) coding and FPGA(Field Programmable Gate Array) implementation results for the proposed structure show 39% and 32% gate count reduction in comparison with those of the conventional structure, respectively. Due to its efficient processing scheme, the proposed SAD processor structure can be widely used in size dominant H.264 chip.

Evaluation of Accuracy and Inaccuracy of Depth Sensor based Kinect System for Motion Analysis in Specific Rotational Movement for Balance Rehabilitation Training (균형 재활 훈련을 위한 특정 회전 움직임에서 피검자 동작 분석을 위한 깊이 센서 기반 키넥트 시스템의 정확성 및 부정확성 평가)

  • Kim, ChoongYeon;Jung, HoHyun;Jeon, Seong-Cheol;Jang, Kyung Bae;Chun, Keyoung Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.228-234
    • /
    • 2015
  • The balance ability significantly decreased in the elderly because of deterioration of the neural musculature regulatory mechanisms. Several studies have investigated methods of improving balance ability using real-time systems, but it is limited by the expensive test equipment and specialized resources. Recently, Kinect system based on depth data has been applied to address these limitations. Little information about accuracy/inaccuracy of Kinect system is, however, available, particular in motion analysis for evaluation of effectiveness in rehabilitation training. Therefore, the aim of the current study was to evaluate accuracy/inaccuracy of Kinect system in specific rotational movement for balance rehabilitation training. Six healthy male adults with no musculoskeletal disorder were selected to participate in the experiment. Movements of the participants were induced by controlling the base plane of the balance training equipment in directions of AP (anterior-posterior), ML (medial-lateral), right and left diagonal direction. The dynamic motions of the subjects were measured using two Kinect depth sensor systems and a three-dimensional motion capture system with eight infrared cameras for comparative evaluation. The results of the error rate for hip and knee joint alteration of Kinect system comparison with infrared camera based motion capture system occurred smaller values in the ML direction (Hip joint: 10.9~57.3%, Knee joint: 26.0~74.8%). Therefore, the accuracy of Kinect system for measuring balance rehabilitation traning could improve by using adapted algorithm which is based on hip joint movement in medial-lateral direction.

Seismic Energy Demand of Structures Depending on Ground Motion Characteristics and Structural Properties (지반 운동과 구조물 특성에 따른 구조물의 에너지 요구량)

  • Choi, Hyun-Hoon;Kim, Jin-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.59-68
    • /
    • 2005
  • The energy-based seismic design method Is more rational in comparison with current seismic design code in that it can directly account for the effects of cumulative damage by earthquake and hysteretic behavior of the structure. However there are research results that don't reach a consensus depending on the ground motion characteristic and structural properties. For that reason in this study the influences of ground motion characteristics and structural properties on energy demands were evaluated using 100 earthquake ground motions recorded in different soil conditions, and the results obtained were compared with those of previous works. Results show that ductility ratios and sue conditions have significant influence on input energy. The results show that the ratio of hysteretic to input energy is considerably influenced by the ductility ratio, damping ratio, and strong motion duration, while the effect of site condition is insignificant.

A Rehabilitation Training System Using the infrared LED based Motion Analysis (적외선 LED 기반 모션 분석을 통한 재활훈련 시스템)

  • Choi, Wan;Lim, Chul-Su;Kim, Tae-Young
    • Journal of the Korea Computer Graphics Society
    • /
    • v.13 no.4
    • /
    • pp.29-36
    • /
    • 2007
  • The objective of this paper is to develop the motion recognition method for the rehabilitation program of the people with physical disabilities. Using the infrared ray LED, this method gets the information of the user's motion and tells the difference between the information we get and the pre-defined information. In order to get the fast recognition and comparison, this method positions the specific coordinates of infrared ray LED in the pre-classified sector which keeps certain distance and angle from the point of origin. The result in our experiment shows the speed over 20 frames per second in every motion, and we are satisfied the rate for the recognition of the motions which is near 98%.

  • PDF