• 제목/요약/키워드: Motion Artifacts

검색결과 179건 처리시간 0.025초

독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출 (Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation)

  • 전학재;김정도;임승주
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

데이터 기반 게이팅을 이용한 PET 영상의 움직임 인공물의 정량적 비교 (Quantitative Comparison of Motion Artifacts in PET Images using Data-Based Gating)

  • 김진영;진계환
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.91-98
    • /
    • 2023
  • 본 논문에서는 자체 제작한 움직임 팬텀을 이용하여 다양한 호흡모사를 하고, PET/CT 장비 내의 데이터기 기반 보정프로그램을 적용하여 영상을 획득하고, 영상의 SUVmax 및 병변 부피를 분석하여 호흡에 따른 장기 또는 종양의 움직임으로 인한 인공물의 감소효과를 확인하였다. 이동거리 3 cm에서 데이터 기반 게이팅을 적용한 영상이 데이터 기반 게이팅을 적용하지 않은 영상보다 SUVmax가 팬텀 구의 지름이 10 mm, 13 mm, 17 mm, 22 mm, 28 mm, 37 mm에서 각각 2.37, 2.02, 1.44, 1.20, 0.42, 0.52 향상시키는 것으로 나타났고, 향상률로 표시하면 각각 72.5%, 73.3%, 51.3%, 25.8%, 8.6%, 7.2%이었다. 크기가 작은 병소의 SUVmax의 개선효과가 크게 나타났다. 데이터 기반 게이팅을 적용하지 않았을 때에 비하여 적용하였을 때에 1 cm, 2 cm, 3 cm에서 각각 5%, 12%, 18%의 영상의 면적이 감소하는 개선효과가 있었고, 그리고 움직임에 의한 인공물이 클 때 감소 효과도 커졌다. 데이터 기반 게이팅을 적용하면 검사절차가 간소화되고, 사술자의 피폭선량 감소효과와 더불어 호흡으로 인한 인공물을 감소시켜 영상의 질을 개선할 수 있음을 확인하였다.

웨이브릿 변환 영역에서의 프랙탈을 이용한 동영상 압축 (Fractal Viedo Coding in Wavelet Transform Domain)

  • 배성호;한동석;박길흠
    • 한국정보처리학회논문지
    • /
    • 제4권4호
    • /
    • pp.1121-1131
    • /
    • 1997
  • 높은 앞축율을 가지는 동영상 압축 방법에 있어, 공간영역에서의 프랙탈을 이용한 동영상 앞축 방법은 복원영상의 블록화 현상이 두드러지는 단점이 있고, 웨이브릿 / 변환 영역에서의 동영상 압축 방법은 에지의 열화가 생기는 단점이 있다. 그러므로 본 논문에서는 이러한 단점을 보완하기 위해 높은 압축률에서도 에지가 선명하고 블록화 현상이 없는 웨이브릿 변환 영역에서의 프랙탈을 이용한 동영상 압축 방법을 제안한다 제안한 방법에서는 서로 다른 부대역간의 상관성을 이용하여 가변 블록 크기의 움 직임을 추정하고, 움직임 추청에 의하여 효과적으로 부호화되지 않는 웨이브릿 계수들은 저해상도 부대역에서 고해상도 부대역을 계층적으로 추정하는 프레임간 프랙탈 부호화 한다. 실험을 통하여 제안한 방법이 기존의 프랙탈과 웨이브릿을 이용한 동영상 부호와 방법도 더 좋은 성능을 나타냄을 보였다.

  • PDF

유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선 (Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination)

  • 이재흔;김현진;임인철
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.307-314
    • /
    • 2015
  • 유방 자기공명영상검사 시 확산강조영상에서 발생하는 심장과 폐에 의한 불수의적 움직임 인공물과 감소된 영상영역 에코평면영상기법으로 발생하는 둘러겹침 인공물을 추가적인 사전포화기법을 사용하여 이를 저감화시키고자 하였다. 2014년 08월 1일부터 11월 30일까지 여성 환자 38명을 대상으로 하였으며 사용 장비로는 유방 검사에 최적화된 3.0T와 유방 전용 코일을 사용하였다. 영상의 평가와 분석은 정량적, 정성적 분석을 하였으며 통계적 유의성은 Paired T-test와 Wilcoxon rank test를 하였다. 결과적으로 추가적인 사전포화펄스의 사용으로 정량적인 평가에서는 병변에서 15.69%, 병변 근접 부위에서 13.72%, 지방에서 20.63%의 증가를 보였으며, 대조도 대 잡음비의 경우는 병변과 병변 근접 부위에서 10.58%, 병변과 지방 부위에서 12.03%의 증가로 나타났다. 정성적인 평가에서는 확산경사계수 0에서 22.05%, 1000에서 21.42%, 현성확산계수에서 16.10%의 증가로 나타났으며, 통계적 평가에서는 신호 대 잡음비와 대조도 잡음비, 확산경사계수와 현성확산계수에서 모두 유의한 결과로 나타났다(p<0.05). 따라서 사전포화펄스의 추가적인 사용으로 유방 자기공명영상 검사에서 확산강조영상 획득 시 위상 부호화 방향으로 발생하는 불수의적 움직임 인공물과 둘러겹침 인공물이 감소가 되어 최적의 영상을 얻을 수 있을 것으로 판단된다.

저 전송율 비디오 부호화를 위한 효율적인 고속 움직임추정 알고리즘과 영상 분할기법 (Efficient Fast Motion Estimation algorithm and Image Segmentation For Low-bit-rate Video Coding)

  • 이병석;한수영;이동규;이두수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.211-214
    • /
    • 2001
  • This paper presents an efficient fast motion estimation algorithm and image segmentation method for low bit-rate coding. First, with region split information, the algorithm splits the image having homogeneous and semantic regions like face and semantic regions in image. Then, in these regions, We find the motion vector using adaptive search window adjustment. Additionally, with this new segment based fast motion estimation, we reduce blocking artifacts by intensively coding our interesting region(face or arm) in input image. The simulation results show the improvement in coding performance and image quality.

  • PDF

단일 영상 비균일 블러 제거를 위한 다중 학습 구조 (Multi-task Architecture for Singe Image Dynamic Blur Restoration and Motion Estimation)

  • 정형주;장현성;하남구;연윤모;권구용;손광훈
    • 한국멀티미디어학회논문지
    • /
    • 제22권10호
    • /
    • pp.1149-1159
    • /
    • 2019
  • We present a novel deep learning architecture for obtaining a latent image from a single blurry image, which contains dynamic motion blurs through object/camera movements. The proposed architecture consists of two sub-modules: blur image restoration and optical flow estimation. The tasks are highly related in that object/camera movements make cause blurry artifacts, whereas they are estimated through optical flow. The ablation study demonstrates that training multi-task architecture simultaneously improves both tasks compared to handling them separately. Objective and subjective evaluations show that our method outperforms the state-of-the-arts deep learning based techniques.

Reliability-Based Deblocking Filter for Wyner-Ziv Video Coding

  • Dinh, Khanh Quoc;Shim, Hiuk Jae;Jeon, Byeungwoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권2호
    • /
    • pp.129-142
    • /
    • 2016
  • In Wyner-Ziv coding, video signals are reconstructed by correcting side information generated by block-based motion estimation/compensation at the decoder. The correction is not always accurate due to the limited number of parity bits and early stopping of low-density parity check accumulate (LDPCA) decoding in distributed video coding, or due to the limited number of measurements in distributed compressive video sensing. The blocking artifacts caused by block-based processing are usually conspicuous in smooth areas and degrade the perceptual quality of the reconstructed video. Conventional deblocking filters try to remove the artifacts by treating both sides of the block boundary equally; however, coding errors generated by block-based processing are not necessarily the same on both sides of the block boundaries. Such a block-wise difference is exploited in this paper to improve deblocking for Wyner-Ziv frameworks by designing a filter where the deblocking strength at each block can be non-identical, depending on the reliability of the reconstructed pixels. Test results show that the proposed filter not only improves subjective quality by reducing the coding artifacts considerably, but also gains rate distortion performance.

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MR Imaging of the Liver

  • Kim, Doo Ri;Kim, Bong Soo;Lee, Jeong Sub;Choi, Guk Myung;Kim, Seung Hyoung;Goh, Myeng Ju;Song, Byung-Cheol;Lee, Mu Sook;Lee, Kyung Ryeol;Ko, Su Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.71-81
    • /
    • 2017
  • Purpose: To compare three, motion-resistant, T1-weighted MR sequences on the hepatobiliary phase for gadoxetic acid-enhanced MR imaging of the liver. Materials and Methods: In this retrospective study, 79 patients underwent gadoxetic acid-enhanced, 3T liver MR imaging. Fifty-nine were examined using a standard protocol, and 20 were examined using a motion-resistant protocol. During the hepatocyte-specific phase, three MR sequences were acquired: 1) gradient recalled echo (GRE) with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); 2) radial GRE with the interleaved angle-bisection scheme (ILAB); and 3) radial GRE with golden-angle scheme (GA). Two readers independently assessed images with motion artifacts, streaking artifacts, liver-edge sharpness, hepatic vessel clarity, lesion conspicuity, and overall image quality, using a 5-point scale. The images were assessed by measurement of liver signal-to-noise ratio (SNR), and tumor-to-liver contrast-to-noise ratio (CNR). The results were compared, using repeated post-hoc, paired t-tests with Bonferroni correction and the Wilcoxon signed rank test with Bonferroni correction. Results: In the qualitative analysis of cooperative patients, the results for CAIPIRINHA had significantly higher ratings for streak artifacts, liver-edge sharpness, hepatic vessel clarity, and overall image quality as compared to, radial GRE, (P < 0.016). In the imaging of uncooperative patients, higher scores were recorded for ILAB and GA with respect to all of the qualitative assessments, except for streak artifact, compared with CAIPIRINHA (P < 0.016). However, no significant differences were found between ILAB and GA. For quantitative analysis in uncooperative patients, the mean liver SNR and lesion-to-liver CNR with radial GRE were significantly higher than those of CAIPIRINHA (P < 0.016). Conclusion: In uncooperative patients, the use of the radial GRE sequence can improve the image quality compared to GRE imaging with CAIPIRINHA, despite the data acquisition methods used. The GRE imaging with CAIPIRINHA is applicable for patients without breath-holding difficulties.

게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백 (Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study)

  • 김태호;;;;이레나;김시용
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.72-78
    • /
    • 2014
  • 연구의 목적은 의사호흡정지(QBH) 바이오 피드백이 의료영상획득 시간의 큰변화 없이 잔류 호흡 운동을 조절함으로써 호흡 운동에 의한 영상 오류를 줄이고, 게이트 3차 흉부 자기 공명 영상을 향상시킬 수 있다는 가설을 실험하는 것이다. 가설을 확인하기 위해 건강한 다섯 사람을 대상으로 3T 지멘스 엠알아이의 호흡 탐색기가 포함된 T2 가중 스페이스 엠알 펄스 시퀀스를 이용해 두번의 게이트 자기공명 영상 연구를 시행 하였다: 자유 호흡 상태와 의사호흡정지 바이오 피드백 호흡상태, 의사호흡정지 바이오 피드백 시스템은 알피엠(RPM) 시스템(실시간 위치 관리시스템, 베리안)을 사용하여, 복부의 외부 위치를 측정하고, 음향과 시각적으로 각각의 호흡주기의 90% 위치에서 2초 숨을 정지하도록 안내하는 방법을 사용했다. 평가방법은 의사호흡정지 바이오 피드백 시스템을 이용시 간 상부의 호흡정지모습의 재현성이 게이팅 영역 내에서 향상되는지를 지원자의 실험을 통해 평가하였다. 자유호흡상태와 의사호흡정지 바이오 피드백상태에서 3차 흉부자기공명영상내에 호흡 운동에 의한 영상 오류와 게이팅영역 내에서의 잔류 호흡 운동 조절여부도 함께 평가했다. 또한, 복부 변위의 RMSE도 (제곱근오차) 조사되었다. 의사호흡정지 바이오 피드백방법을 사용함으로 자유호흡의 경우보다 게이트 3차 흉부 엠알 영상에서 폐와 간에서 호흡운동에 의한 영상오류의 감소 결과를 획득했다(영상획득시간: ~6분). 이는 의사호흡정지 바이오 피드백사용시, 게이팅 영역에서 복부 운동 감소와 횡경막의 잔류 움직임 감소가 일치함을 의미한다. 따라서, 알피엠을 통해 얻은 복부 변위의 전체 자료에서평균 RMSE는 (제곱근오차) 자유 호흡의 2.0 mm에 비해 7 mm (67% 감소, p값=0.02)로 감소하였으며, 게이팅영역만을 고려했을때는 자유 호흡의 1.7 mm가 의사호흡정지 바이오 피드백 호흡을 사용함으로써 0.7 mm (58 % 감소, p값=0.14) 로 개선되었다. 선형 피팅을 사용하여 얻은 평균 기준 이동값은 의사호흡정지 바이오 피드백 을 사용하면 자유 호흡 5.5 mm/분보다 0.6 mm/분(89% 감소, p값=0.017)으로 감소되었다. 이 연구는 의사호흡정지 바이오 피드백을 이용해 게이트 3차 흉부 자기 공명 영상 중에 간 상부의 호흡정지 재현성이 향상되는 것을 보여 주었다. 이 시스템은 내부 해부학의 운동을 조절함으로써 게이트 의료 영상과 방사선 치료에 임상적으로 적용 할 수 있다.

선형 움직임 기반 프레임률 향상 기법 (Motion Linearity-based Frame Rate Up Conversion Method)

  • 김동형
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.734-740
    • /
    • 2017
  • 낮은 프레임률을 가지는 동영상을 높은 프레임률 디스플레이 장치를 통해 재생하는 경우 프레임률 향상기법이 필요하다. 프레임 향상 기법은 연속된 원본 프레임 사이에 프레임을 보간함으로써 생성하며 이러한 프레임 보간방법은 크게 프레임 복사 기법과 움직임벡터 기반의 보간기법으로 나뉜다. 프레임 복사 기법은 단순히 보간하고자 하는 프레임의 이전 또는 이후 프레임을 복사하는 기법으로 매우 낮은 복잡도를 가지지만 저키현상이 발생하는 단점이 있다. 움직임 벡터 추정 및 보상을 통한 프레임 보간기법은 다시 화소단위의 방법과 블록단위의 움직임 추정 방법으로 나눌 수 있다. 화소기반의 경우 영역별 다른 보간 방법을 사용하여 보간을 수행하며 높은 복잡도를 가지는 단점이 있다. 블록기반 방법은 상대적으로 낮은 복잡도를 가지지만 블록킹현상이 발생한다는 단점을 가진다. 제안하는 방법은 블록단위의 움직임 추정 기반 프레임률 향상기법으로 프레임내 움직임의 선형성을 이용하여 움직임을 추정한다. 이 과정에서 보간하고자 하는 프레임 이전 두 프레임과 이후 한 프레임을 사용하여 움직임 추정 및 보상을 수행함으로써 프레임을 보간하다. 실험결과 제안한 알고리즘은 객관적 화질 측면에서 이전의 다른 방법과 비교하여 높은 성능을 보이고 특히 해상도가 높은 경우 더욱 우수한 성능을 가지는 것으로 나타났으며 주관적 화질 또한 상대적으로 우수한 것을 볼 수 있었다.