• Title/Summary/Keyword: Motion Analysis System

Search Result 2,516, Processing Time 0.028 seconds

Intratester Reliability of 3 Dimensional Motion Analysis System on Normal Subjects by a Tester (3차원 운동분석 시스템을 이용한 보행분석에 있어서 검사간의 재현도)

  • Lee, Moon-Sook;Wui, Hyang-Mi
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.1
    • /
    • pp.383-392
    • /
    • 1995
  • The purpose of this investigation was to determine the intratester reliability of measurements obtained with 3 Dimensional Motion Analysis System(3DMAS) by tester on normal subject. Twenty subjects between the ages of 9 and 29(x=22) were evaluated with 3DMAS using a test-retest reliability procedure after a familiarization session. Computerized 3DMAS was done with 4 50 - Hz CCD cameras connected to the ELITE system(B. T. S., Italy) and kinetic data were collected from the AMTI force platform(AMTI., U. S. A). Data were analyzed by the Eliclinic software to obtain gait parameters, joint angles and joint internal moment and power. Test-retest revealed intraclass correlation coefficients from .80 to .99. A series of paired t-tests revealed no significant differences between test and retest values. Finally, it was concluded that tester with 3DMAS could obtain reliable measurements with 3DMAS for determining kinetic, kinematic and gait parameters in normal subjects.

  • PDF

Parameter Analysis of Muscle Models for Arm Movement (팔 근육운동의 파라미터 분석)

  • Kim, Lae-Kyeom;Tak, Tae-Oh
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.155-161
    • /
    • 2008
  • Muscle force prediction in forward dynamic analysis of human motion depends many muscle parameters associated with muscle actuation. This research studies the effects of various parameters of Hill type muscle model using the simple hand raising motion. Motion analysis is carried out using motion capture system, and each muscle force is recorded for comparison with muscle model generated muscle force. Using Hill type muscle model, muscle force for generating the same hand rasing motion was setup adjusting 5 activation parameters. The test showed the importance of activation parameters on the accurate generation of muscle force.

  • PDF

Development of a motion system operating software for a driving simulator (차량 시뮬레이터의 운동시스템 구동소프트웨어 개발)

  • 박경균;박일경;조준희;이운성;김정하
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.496-499
    • /
    • 1997
  • This paper describes the operating software of a motion system developed for a driving simulator, consisting of a six degree of freedom Stewart platform driven hydraulically. The drive logic, consisting of an washout algorithm, inverse kinematic analysis, and a control algorithm, has been developed and applied for creating high fidelity motion cues. The basic environment of the operating software is based on LabVIEW 4.0 and DLL modules compiled by Fortran.

  • PDF

Implementation of A 3-D Animation System Based on The MPEG-4 SNHC Standard (MPEG-4 SNHC 표준을 따르는 3차원 애니메이션 시스템의 구현)

  • 윤승욱;안정환;전정희;호요성
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.129-132
    • /
    • 2002
  • In this paper, we propose a 3-D animation system to track and analyze motion of the human object. The proposed system consists of two separate layers: motion analysis layer and 3-D model registration layer. Following the MPEG-4 SNHC standard, we generate object motion using body definition and animation parameters. In the implemented system, we acquire human motion data from a single camera and extract body definition parameters from arbitrary VRML human models.

  • PDF

Target Motion Analysis for Active/Passive Mixed-Mode Sonar Systems

  • Taek, Lim-Young;Lyul, Song-Taek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.172.5-172
    • /
    • 2001
  • Target Motion Analysis(TMA) for Passive Sonar Systems with bearing-only measurements needs to enhance system observability to improve target tracking performance by ownship maneuvering. However, tracking problem incurred by weak observaility result in slow convergence of the target estimates. On the other hand, active sonar systems do not have problem associated with system observaility. However, it drawback related to system survivability. In this paper, the algorithm that could be used in Active/passive Mixed-Mode Sonar Systems is proposed to analyze maneuvering target motion and to improve TMA performance. The proposed TMA algorithm is tested by a series of computer simulation runs and the results ...

  • PDF

Implementation of Badminton Motion Analysis and Training System based on IoT Sensors

  • Sung, Nak-Jun;Choi, Jin Wook;Kim, Chul-Hyun;Lee, Ahyoung;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.18 no.4
    • /
    • pp.19-25
    • /
    • 2017
  • In this paper, we designed and implemented IoT sensors based badminton motion analysis and training system that can be readily used by badminton players with PC. Unlike the traditional badminton training system which uses signals of the flags by coach, the proposed electronic training system used IoT sensors to automatically detect and analysis the motions for badminton players. The proposed badminton motion analysis and training system has the advantage with low power, because it communicates with the program through BLE communication. The badminton motion analysis system automatically measures the training time according to the player's movement, so it is possible to collect objective result data with less errors than the conventional flag signal based method by coach. In this paper, training data of 5 athletes were collected and it provides the feedback function through the visualization of each section of the training results by the players which can enable the effective training. For the weakness section of each player, the coach and the player can selectively and repeatedly perform the training function with the proposed training system. Based on this, it is possible to perform the repeated training on weakness sections and they can improve the response speed for these sections. Continuous research is expected to be able to compare more various players' agility and physical fitness.

A Study on the Global Motion Performance of Floater and Mooring Due to Arrangement of Detachable Mooring System (탈착형 계류시스템 배치에 따른 부유식 해양구조물의 운동 및 계류성능에 관한 연구)

  • Kangsu Lee;Hyun-Sung Kim;Byoung Wan Kim
    • Journal of Wind Energy
    • /
    • v.14 no.2
    • /
    • pp.26-33
    • /
    • 2023
  • In this study, the global response characteristics of floater and mooring for floating offshore wind turbine with a detachable mooring system are performed. Global motion and structural response result extracted from the coupled motion analysis of 10MW DTU floating offshore wind turbine with detachable mooring system modeled by high-order boundary element model and finite element mesh, were used to study the characteristics of tension on mooring lines subjected to three different types of ocean loads. Breaking limit of mooring line characterized by wind, current and wave load has a major effect on the distribution of mooring tension found in time domain analysis. Based on the numerical results of coupled motion analysis, governing equation for calculating the motion response of a floater under ocean loads, and excitation force and surge motion and tension respectively are presented using excursion curve. It is found that the response of floater is reliable and accurate for calculating the tension distributions along the mooring lines under complex loadings. This means that the minimun breaking limit of mooring system satisfied a design criteria at ultimate ocean environmental loading condtions.

Response of Base Isolation System Subjected to Spectrum Matched Input Ground Motions (스펙트럼 적합 입력지반운동에 의한 면진구조의 응답 특성)

  • Kim, Jung Han;Kim, Min Kyu;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2013
  • Structures in a nuclear power system are designed to be elastic even under an earthquake excitation. However a structural component such as an isolator shows inelastic behavior inherently. For the seismic assessment of nonlinear structures, response history analysis should be performed. In this study, the response of base isolation system was analyzed by response history analysis for the seismic performance assessment. Firstly, several seismic assessment criteria for a nuclear power plant structure were reviewed for the nonlinear response history analysis. Based on these criteria, the spectrum matched ground motion generation method modifying a seed earthquake ground motion time history was adjusted. Using these spectrum matched accelerograms, the distribution of displacement responses of the simplified base isolation system was evaluated. The resulting seismic responses excited by the modified ground motion time histories and the synthesized time history generated by stochastic approach were compared. And the response analysis of the base isolation system considering the different intensities in each orthogonal direction was performed.

A Structural Analysis on the Leaflet Motion Induced by the Blood Flow for Design of a Bileaflet Mechanical Heart Valve Prosthesis

  • Kwon, Young-Joo;Kim, Chang-Nyung;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1316-1323
    • /
    • 2003
  • This paper presents a structural analysis on the rigid and deformed motion of the leaflet induced by the blood flow required in the design of a bileaflet mechanical heart valve (MHV) prosthesis. In the study on the design and the mechanical characteristics of a bileaflet mechanical heart valve, the fluid mechanics analysis on the blood flow passing through leaflets, the kinetodynamics analysis on the rigid body motion of the leaflet induced by the pulsatile blood flow, and the structural mechanics analysis on the deformed motion of the leaflet are required sequentially and simultaneously. Fluid forces computed in the previous hemodynamics analysis on the blood flow are used in the kinetodynamics analysis on the rigid body motion of the leaflet. Thereafter, the structural mechanics analysis on the deformed motion of the leaflet follows to predict the structural strength variation of the leaflet as the leaflet thickness changes. Analysis results show that structural deformations and stresses increase as the fluid pressure increases and the leaflet thickness decreases. Analysis results also show that the leaflet becomes structurally weaker and weaker as the leaflet thickness becomes smaller than 0.6 mm.

Motion analysis system using image processing (화상처리를 이용한 동작분석 시스템에 관한 연구)

  • 박경수;반영환;이안재;임창주;오인석;이현철
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.71-75
    • /
    • 1997
  • This paper presents the development of videobased 3-dimensional tracking system. Measurement of human motion is important in the application of ertonomics. The system uses advanced direct video measurement technology. Passive retro-reflecting markers are attached to a subject and movements of markers are observed by two CCD cameras. Infrared light emitted near the CCD cameras is reflected by the markers and is detected by the cameras. The images are captured by Samsung MVB302 board and the centers of markers are calculated by DSP program. The positions of markers are transferred from MVB02 board to the computer through AT bus. The computer then tracks the position of each marker and saves the data. This system has dynamic accuracy with 0.7% average error and 4.2% maximum error, and the sampling rate to 6 .approx. 10 Hz, and this system can analyse the trajectory and speed of the marker. The results of this study can be used for operator's motion analysis, task analysis, and hand movement characteristic analysis.

  • PDF